Power Supply Module of the Multi-Flex Server
Parsed from file INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB.mib
Module: INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB
Vendor: Intel Corporation
Module: INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB
[Automatically extracted from oidview.com]
multiFlexServerPwrMibModule MODULE-IDENTITY LAST-UPDATED "200708161330Z" ORGANIZATION "Intel Corporation" CONTACT-INFO "Brian Kurle Intel Corporation JF5-2-C3 Tel: 503-712-5032 E-Mail: [email protected]" DESCRIPTION "Power Supply Module of the Multi-Flex Server" REVISION "200708161330Z" DESCRIPTION "Fixed up minor errors causing some managers grief (ommission or addition of commas in lists) Reordered Revision to reverse chronological as some browsers choke, cleaned up some other simple nit-picky errors" REVISION "200707201530Z" DESCRIPTION "Cleaned up much of the documentation to provide more accurate usage of the individual objects. Particularly, paid attention to the double usage of the pwrSupplyTable where some columns are relevant only if the pwrSupplyType is a power supply, and others only relevant if it is a fan blank." REVISION "200706191130Z" DESCRIPTION "Finalized the Version information for the MIB based on information available/used by the rest of the system (e.g., the GUI/fwupdate) Dropped pwrSupplyBmcFirmwareVersion. Added pwrSupplyOpCodeVersion & pwrSupplyBootBlockVersion." REVISION "200706072030Z" DESCRIPTION "Added the IdromBinary16 to represent the asset tag, part number, and serial number fields within the IDROM fields." REVISION "200706071330Z" DESCRIPTION "Corrected maximum/nominal IDROM parameters and comments" REVISION "200705301900Z" DESCRIPTION "Introduced the INT32withException type so that enumeration can be managed globally" REVISION "200705221400Z" DESCRIPTION "Added notApplicable and unknown states to various entries Moved Presence to first column so it's obvious in table display" REVISION "200704271600Z" DESCRIPTION "Cleaned up the pwrSupplyTable (removed input VDC and corrected column sequencing" REVISION "200704251400Z" DESCRIPTION "Dropped fanRpmSetting & fanCoefficient from the pwrSupplyFanTable (minor column renumbering). Dropped pwrSupplyNumOfAxis & pwrSupplyFansPerAxis from pwrSupplyTable" REVISION "200704181905Z" DESCRIPTION "Moved the trees and chassis nodes around to accomodate the unique power supply characteristics. Added the missing numOfPwrUnknowns & pwrSupplyUnknownPresenceMask" REVISION "200704091030Z" DESCRIPTION "Renamed pwrSupplyFirmwareVersion to pwrSupplyBmcFirmwareVersion to be consistent in naming with other subsystems" REVISION "200704021100Z" DESCRIPTION "Updated comments to tag fields that may be either statically returned, or that may potentially be removed Added Power supply sensors/status" REVISION "200703131030Z" DESCRIPTION "pwrSupplyTable data now complies with IDROM (DID/DSD) information. Changed maxPwrSupplies -> maxPwrSupplyFrus Added numOfPwrBlanks & pwrSupplyBlankPresenceMask Added some token information for the expected fan information Renumbered / reorganized accordingly" REVISION "200703061030Z" DESCRIPTION "Changed Mask representations from an Opaque to a DisplayString at the request of the architects such that it now is an ASCII representation of bit string reflecting the presence with the left most 'bit' being bit 1 and max* bits being represented." REVISION "200702221700Z" DESCRIPTION "Renamed MIB file and updated internal relevance to formal product name Multi-Flex Server" REVISION "200611070701Z" DESCRIPTION "Consolodated use of Presence datatype and changed 'chassis' to 'chassis'" REVISION "200609291529Z" DESCRIPTION "Partitioned off and created as it's own module" ::= { regModule 17 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.343.2.19.1.1.1.1 | multiFlexServerRegModule | 0 | 0 | Registry module definitions for entire Multi-Flex Server MIB system |
1.3.6.1.4.1.343.2.19.1.1.1.2 | multiFlexServerTcModule | 0 | 0 | Textual Conventions used within INTELCORPORATION-MULTI-FLEX-SERVER-*MIB |
1.3.6.1.4.1.343.2.19.1.1.1.10 | multiFlexServerMibModule | 0 | 0 | Managment access to Multi-Flex Server chassis. There is still some question where under the products tree this belongs the chassiā¦ |
1.3.6.1.4.1.343.2.19.1.1.1.11 | multiFlexServerCmmMibModule | 0 | 0 | CMM Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.12 | multiFlexServerBladesMibModule | 0 | 0 | Blade Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.13 | multiFlexServerSwitchMibModule | 0 | 0 | Switch Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.14 | multiFlexServerScmMibModule | 0 | 0 | Controller Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.15 | multiFlexServerDrivesMibModule | 0 | 0 | Shared Disks Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.16 | multiFlexServerFanMibModule | 0 | 0 | Fan Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.18 | multiFlexServerStorageMibModule | 0 | 0 | Storage Module of the Multi-Flex Server |