Reference record for OID 1.3.6.1.4.1.358.4.4.7.1.1.2



parent
1.3.6.1.4.1.358.4.4.7.1.1 (padOperTable, padEntry)
node code
2
node name
padDssFlowControl
dot oid
1.3.6.1.4.1.358.4.4.7.1.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pacesetter(358) pacesetterMIB(4) portProtocol(4) padProtocol(7) padOperInfo(1) padOperTable(1) padDssFlowControl(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pacesetter(358) pacesetterMIB(4) portProtocol(4) padProtocol(7) padOperInfo(1) padEntry(1) padDssFlowControl(2)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) pacesetter(358) pacesetterMIB(4) portProtocol(4) padProtocol(7) padTable(1) padOperTable(1) padDssFlowControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) pacesetter(358) pacesetterMIB(4) portProtocol(4) padProtocol(7) padTable(1) padEntry(1) padDssFlowControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) pacesetter(358) pacesetterMIB(4) portProtocol(4) padProtocol(7) padOperInfo(1) padOperTable(1) padDssFlowControl(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) pacesetter(358) pacesetterMIB(4) portProtocol(4) padProtocol(7) padOperInfo(1) padEntry(1) padDssFlowControl(2)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pacesetter(358) pacesetterMIB(4) portProtocol(4) padProtocol(7) padTable(1) padOperTable(1) padDssFlowControl(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pacesetter(358) pacesetterMIB(4) portProtocol(4) padProtocol(7) padTable(1) padEntry(1) padDssFlowControl(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/pacesetter/pacesetterMIB/portProtocol/padProtocol/padOperInfo/padOperTable/padDssFlowControl
  • /iso/identified-organization/dod/internet/private/enterprise/pacesetter/pacesetterMIB/portProtocol/padProtocol/padOperInfo/padEntry/padDssFlowControl
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/pacesetter/pacesetterMIB/portProtocol/padProtocol/padTable/padOperTable/padDssFlowControl
  • /iso/org/dod/internet/private/enterprise/pacesetter/pacesetterMIB/portProtocol/padProtocol/padTable/padEntry/padDssFlowControl
  • /iso/org/dod/internet/private/enterprises/pacesetter/pacesetterMIB/portProtocol/padProtocol/padOperInfo/padOperTable/padDssFlowControl
  • /iso/org/dod/internet/private/enterprises/pacesetter/pacesetterMIB/portProtocol/padProtocol/padOperInfo/padEntry/padDssFlowControl
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/pacesetter/pacesetterMIB/portProtocol/padProtocol/padTable/padOperTable/padDssFlowControl
  • /iso/iso-identified-organization/dod/internet/private/enterprises/pacesetter/pacesetterMIB/portProtocol/padProtocol/padTable/padEntry/padDssFlowControl
  • Description by mibdepot

    DSS flow control specifies that RTS/CTS data set signals are used for
    flow control. If DSS flow control is selected, the PAD forces X.3
    parameters 5 and 12 to values of 0 (flow control using XON/XOFF is
    not possible).

    Parsed from file pacesetter70-soho.mib.txt
    Company: adc_kentrox
    Module: PACESETTER-COMMON-MIB

    Information by mibdepot

    padDssFlowControl OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "DSS flow control specifies that RTS/CTS data set signals are used for flow control. If DSS flow control is selected, the PAD forces X.3 parameters 5 and 12 to values of 0 (flow control using XON/XOFF is not possible)." ::= { padEntry 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.358)

    Weir Don

    Brothers (10)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.358.4.4.7.1.1.1 padOperEntry, padPortIndex 9 9 A unique value for each port. The interface associated with a
    particular value of this object is the same interface as identifi…
    1.3.6.1.4.1.358.4.4.7.1.1.3 padX28Profile 0 0 The X.28 profile index specifies the number of one of the pre-defined
    sets of X.3 parameter values that control the line between…
    1.3.6.1.4.1.358.4.4.7.1.1.4 padX29Profile 0 0 The X.29 profile index specifies one of the pre-defined sets of X.3
    parameter values that govern the interaction between the cal…
    1.3.6.1.4.1.358.4.4.7.1.1.5 padAutoconnectSelectionCommand 0 0 The pre-stored X.28 selection command is used to indicate whether the
    PAD automatically attempts to establish a data call using…
    1.3.6.1.4.1.358.4.4.7.1.1.6 padRetryTimer 0 0 The PAD uses the retry timer on autoconnect calls to attempt to
    establish the data call if a previous try is unsuccessful or if …
    1.3.6.1.4.1.358.4.4.7.1.1.7 padX121Address 0 0 An X.121 address is required only if the port is configured to
    receive outgoing data calls. The address is used for routing ca…
    1.3.6.1.4.1.358.4.4.7.1.1.8 padInactivityTimer 0 0 The inactivity timer clears a users' call is there is no activity
    (transmission or reception of data) for the specified number o…
    1.3.6.1.4.1.358.4.4.7.1.1.9 padCallAddress 0 0 The Call Address parameter indicates whether the PAD inserts a calling
    address in a Call Request packet and a called address in …
    1.3.6.1.4.1.358.4.4.7.1.1.10 padCharsDiscardDuringFlowControls 0 0 Number of characters discarded during flow control since last time
    statistics cleared.
    1.3.6.1.4.1.358.4.4.7.1.1.11 padFlowControlStatus 0 0 Current flow control status.