The pre-stored X.28 selection command is used to indicate whether the
PAD automatically attempts to establish a data call using a
pre-stored X.28 selection command when a terminal makes a physical
connection to the port. If an Autoconnect selection command is
present, the retry timeris used.
Parsed from file pacesetter70-soho.mib.txt
Company: adc_kentrox
Module: PACESETTER-COMMON-MIB
padAutoconnectSelectionCommand OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The pre-stored X.28 selection command is used to indicate whether the PAD automatically attempts to establish a data call using a pre-stored X.28 selection command when a terminal makes a physical connection to the port. If an Autoconnect selection command is present, the retry timeris used." ::= { padEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.358.4.4.7.1.1.1 | padOperEntry, padPortIndex | 9 | 9 | A unique value for each port. The interface associated with a particular value of this object is the same interface as identifi… |
1.3.6.1.4.1.358.4.4.7.1.1.2 | padDssFlowControl | 0 | 0 | DSS flow control specifies that RTS/CTS data set signals are used for flow control. If DSS flow control is selected, the PAD fo… |
1.3.6.1.4.1.358.4.4.7.1.1.3 | padX28Profile | 0 | 0 | The X.28 profile index specifies the number of one of the pre-defined sets of X.3 parameter values that control the line between… |
1.3.6.1.4.1.358.4.4.7.1.1.4 | padX29Profile | 0 | 0 | The X.29 profile index specifies one of the pre-defined sets of X.3 parameter values that govern the interaction between the cal… |
1.3.6.1.4.1.358.4.4.7.1.1.6 | padRetryTimer | 0 | 0 | The PAD uses the retry timer on autoconnect calls to attempt to establish the data call if a previous try is unsuccessful or if … |
1.3.6.1.4.1.358.4.4.7.1.1.7 | padX121Address | 0 | 0 | An X.121 address is required only if the port is configured to receive outgoing data calls. The address is used for routing ca… |
1.3.6.1.4.1.358.4.4.7.1.1.8 | padInactivityTimer | 0 | 0 | The inactivity timer clears a users' call is there is no activity (transmission or reception of data) for the specified number o… |
1.3.6.1.4.1.358.4.4.7.1.1.9 | padCallAddress | 0 | 0 | The Call Address parameter indicates whether the PAD inserts a calling address in a Call Request packet and a called address in … |
1.3.6.1.4.1.358.4.4.7.1.1.10 | padCharsDiscardDuringFlowControls | 0 | 0 | Number of characters discarded during flow control since last time statistics cleared. |
1.3.6.1.4.1.358.4.4.7.1.1.11 | padFlowControlStatus | 0 | 0 | Current flow control status. |