The inactivity timer clears a users' call is there is no activity (transmission or reception of data) for the specified number of minutes. This feature is used to prevent users from maintaining open channels without engaging in data exchange.
A value of 0 disables the timer.
The default value is 0.
Parsed from file pacesetter70-soho.mib.txt
Company: adc_kentrox
Module: PACESETTER-COMMON-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
padAdminInactivityTimer OBJECT-TYPE SYNTAX INTEGER (0..30) ACCESS read-write STATUS mandatory DESCRIPTION "The inactivity timer clears a users' call is there is no activity (transmission or reception of data) for the specified number of minutes. This feature is used to prevent users from maintaining open channels without engaging in data exchange. A value of 0 disables the timer. The default value is 0." ::= { padAdminInfo 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.358.4.4.7.2.10.0 | padAdminInactivityTimer | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.358.4.4.7.2.1 | padAdminDSSFlowControl | 1 | 1 | DSS flow control specifies that RTS/CTS data set signals are used for flow control. If DSS flow control is selected, the PAD f… |
1.3.6.1.4.1.358.4.4.7.2.2 | padAdminX28Profile | 1 | 1 | The X.28 profile index specifies the number of one of the pre-defined sets of X.3 parameter values that control the line betwee… |
1.3.6.1.4.1.358.4.4.7.2.3 | padAdminX29Profile | 1 | 1 | The X.29 profile index specifies one of the pre-defined sets of X.3 parameter values that govern the interaction between the ca… |
1.3.6.1.4.1.358.4.4.7.2.4 | padAdminAutocconnectSelectionCommand | 1 | 1 | The pre-stored X.28 selection command is used with the autoconnect option. The command may include optional X.25 facilities. … |
1.3.6.1.4.1.358.4.4.7.2.5 | padAdminRetryTimer | 1 | 1 | The PAD uses the retry timer on autoconnect calls to attempt to establish the data call if a previous try is unsuccessful or if… |
1.3.6.1.4.1.358.4.4.7.2.8 | padAdminX121Address | 1 | 1 | An X.121 address is required write if the port is configured to receive outgoing data calls. The address is used for routing … |
1.3.6.1.4.1.358.4.4.7.2.11 | padAdminCallAddress | 1 | 1 | The Call Address parameter indicates whether the PAD inserts a calling address in a Call Request packet and a called address in… |