The X.29 profile index specifies one of the pre-defined sets of X.3 parameter values that govern the interaction between the calling device and the PAD. The PAD uses the profile definition to construct an X.29 SET PAD message which is the first DATA packet the PAD sends after it accepts an incoming call.
The default value is 89.
Parsed from file pacesetter70-soho.mib.txt
Company: adc_kentrox
Module: PACESETTER-COMMON-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
padAdminX29Profile OBJECT-TYPE SYNTAX INTEGER (76..91) ACCESS read-write STATUS mandatory DESCRIPTION "The X.29 profile index specifies one of the pre-defined sets of X.3 parameter values that govern the interaction between the calling device and the PAD. The PAD uses the profile definition to construct an X.29 SET PAD message which is the first DATA packet the PAD sends after it accepts an incoming call. The default value is 89." ::= { padAdminInfo 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.358.4.4.7.2.3.0 | padAdminX29Profile | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.358.4.4.7.2.1 | padAdminDSSFlowControl | 1 | 1 | DSS flow control specifies that RTS/CTS data set signals are used for flow control. If DSS flow control is selected, the PAD f… |
1.3.6.1.4.1.358.4.4.7.2.2 | padAdminX28Profile | 1 | 1 | The X.28 profile index specifies the number of one of the pre-defined sets of X.3 parameter values that control the line betwee… |
1.3.6.1.4.1.358.4.4.7.2.4 | padAdminAutocconnectSelectionCommand | 1 | 1 | The pre-stored X.28 selection command is used with the autoconnect option. The command may include optional X.25 facilities. … |
1.3.6.1.4.1.358.4.4.7.2.5 | padAdminRetryTimer | 1 | 1 | The PAD uses the retry timer on autoconnect calls to attempt to establish the data call if a previous try is unsuccessful or if… |
1.3.6.1.4.1.358.4.4.7.2.8 | padAdminX121Address | 1 | 1 | An X.121 address is required write if the port is configured to receive outgoing data calls. The address is used for routing … |
1.3.6.1.4.1.358.4.4.7.2.10 | padAdminInactivityTimer | 1 | 1 | The inactivity timer clears a users' call is there is no activity (transmission or reception of data) for the specified number… |
1.3.6.1.4.1.358.4.4.7.2.11 | padAdminCallAddress | 1 | 1 | The Call Address parameter indicates whether the PAD inserts a calling address in a Call Request packet and a called address in… |