This object contains the results of power-on self test.
When zero, the unit passed self test okay. When non-zero
and pcomOperStatus indicates a failure the value is a
module-specific error code. When non-zero and pcomOperStatus
indicates a nonFatalFailure the value is a module-specific
non-fatal error code.
Parsed from file DEChub900-Common.mib.txt
Company: None
Module: DECHUB900-COMMON-MIB-V3-0
This object contains the results of power-on self test.
When zero, the unit passed self test okay. When non-zero
and pcomOperStatus indicates a failure the value is a
module-specific error code. When non-zero and pcomOperStatus
indicates a nonFatalFailure the value is a module-specific
non-fatal error code.
Parsed from file DECHUB900-COMMON-MIB-V3-0.mib
Module: DECHUB900-COMMON-MIB-V3-0
Vendor: DEC
Module: DECHUB900-COMMON-MIB-V3-0
[Automatically extracted from oidview.com]
pcomDiagFailure OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the results of power-on self test. When zero, the unit passed self test okay. When non-zero and pcomOperStatus indicates a failure the value is a module-specific error code. When non-zero and pcomOperStatus indicates a nonFatalFailure the value is a module-specific non-fatal error code." ::= { pcomSlot 3 }
pcomDiagFailure OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "This object contains the results of power-on self test. When zero, the unit passed self test okay. When non-zero and pcomOperStatus indicates a failure the value is a module-specific error code. When non-zero and pcomOperStatus indicates a nonFatalFailure the value is a module-specific non-fatal error code." ::= { pcomSlot 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.2.1.3.0 | pcomDiagFailure | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.2.1.1 | pcomOperStatus | 1 | 1 | Describes the current operational state of the device. Operational status may be expressed as one of the following: enabled(1) - … |
1.3.6.1.4.1.36.2.18.11.2.1.2 | pcomAdminStatus | 1 | 1 | enabled(1) - setting this object to enabled causes the device to begin it's power up sequence and attempt to enter its operationa… |
1.3.6.1.4.1.36.2.18.11.2.1.4 | pcomSerialNumber | 1 | 1 | Serial number for the module. This variable is set to a zero length string initially. Users may store a serial number for the mod… |
1.3.6.1.4.1.36.2.18.11.2.1.5 | pcomSlotNumber | 1 | 1 | Number of the slot in which module is inserted, as indicated by pins on the backplane connector. If module is not inserted in a … |
1.3.6.1.4.1.36.2.18.11.2.1.6 | pcomEsn | 1 | 1 | Extended Slot Number assigned to module. An ESN is a 32-bit integer which has a decimal representation that indicates the physica… |