Extended Slot Number assigned to module. An ESN is a 32-bit
integer which has a decimal representation that indicates the
physical connectivity of both local and remote modules to the
hub. The decimal representation is of the form:
ss [aa [bb [cc [dd]]]]
where [] indicates optional. A module inserted directly in the
hub has an ESN 'ss' that is the same as its slot number (e.g 3).
A remote module connected to the local module's 'aa' port has
ESN ssaa. For example, if a concentrator in slot 3 has a
repeater connected to port 2, the repeater has ESN 302.
Dec Hubs can manage devices up to four remote hops away from
the hub.
Parsed from file DEChub900-Common.mib.txt
Company: None
Module: DECHUB900-COMMON-MIB-V3-0
Extended Slot Number assigned to module. An ESN is a 32-bit
integer which has a decimal representation that indicates the
physical connectivity of both local and remote modules to the
hub. The decimal representation is of the form:
ss [aa [bb [cc [dd]]]]
where [] indicates optional. A module inserted directly in the
hub has an ESN 'ss' that is the same as its slot number (e.g 3).
A remote module connected to the local module's 'aa' port has
ESN ssaa. For example, if a concentrator in slot 3 has a
repeater connected to port 2, the repeater has ESN 302.
Dec Hubs can manage devices up to four remote hops away from
the hub.
Parsed from file DECHUB900-COMMON-MIB-V3-0.mib
Module: DECHUB900-COMMON-MIB-V3-0
Vendor: DEC
Module: DECHUB900-COMMON-MIB-V3-0
[Automatically extracted from oidview.com]
pcomEsn OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "Extended Slot Number assigned to module. An ESN is a 32-bit integer which has a decimal representation that indicates the physical connectivity of both local and remote modules to the hub. The decimal representation is of the form: ss [aa [bb [cc [dd]]]] where [] indicates optional. A module inserted directly in the hub has an ESN 'ss' that is the same as its slot number (e.g 3). A remote module connected to the local module's 'aa' port has ESN ssaa. For example, if a concentrator in slot 3 has a repeater connected to port 2, the repeater has ESN 302. Dec Hubs can manage devices up to four remote hops away from the hub." ::= { pcomSlot 6 }
pcomEsn OBJECT-TYPE SYNTAX INTEGER (0..4294967295) ACCESS read-only STATUS mandatory DESCRIPTION "Extended Slot Number assigned to module. An ESN is a 32-bit integer which has a decimal representation that indicates the physical connectivity of both local and remote modules to the hub. The decimal representation is of the form: ss [aa [bb [cc [dd]]]] where [] indicates optional. A module inserted directly in the hub has an ESN 'ss' that is the same as its slot number (e.g 3). A remote module connected to the local module's 'aa' port has ESN ssaa. For example, if a concentrator in slot 3 has a repeater connected to port 2, the repeater has ESN 302. Dec Hubs can manage devices up to four remote hops away from the hub." ::= { pcomSlot 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.2.1.6.0 | pcomEsn | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.2.1.1 | pcomOperStatus | 1 | 1 | Describes the current operational state of the device. Operational status may be expressed as one of the following: enabled(1) - … |
1.3.6.1.4.1.36.2.18.11.2.1.2 | pcomAdminStatus | 1 | 1 | enabled(1) - setting this object to enabled causes the device to begin it's power up sequence and attempt to enter its operationa… |
1.3.6.1.4.1.36.2.18.11.2.1.3 | pcomDiagFailure | 1 | 1 | This object contains the results of power-on self test. When zero, the unit passed self test okay. When non-zero and pcomOperSta… |
1.3.6.1.4.1.36.2.18.11.2.1.4 | pcomSerialNumber | 1 | 1 | Serial number for the module. This variable is set to a zero length string initially. Users may store a serial number for the mod… |
1.3.6.1.4.1.36.2.18.11.2.1.5 | pcomSlotNumber | 1 | 1 | Number of the slot in which module is inserted, as indicated by pins on the backplane connector. If module is not inserted in a … |