Reference record for OID 1.3.6.1.4.1.3854.1.2.2.1.16



parent
1.3.6.1.4.1.3854.1.2.2.1 (hhmsSensorArrayEntry)
node code
16
node names
  • hhmsSensorArrayTempTable
  • hhmsSensorArrayTemp
  • dot oid
    1.3.6.1.4.1.3854.1.2.2.1.16
    type
    OBJECT IDENTIFIER
    asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) akcp(3854) hhmsagent(1) hhmsSensor(2) hhmsSensorArrayTable(2) hhmsSensorArrayEntry(1) hhmsSensorArrayTempTable(16)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) akcp(3854) hhmsagent(1) hhmsSensor(2) hhmsSensorArrayTable(2) hhmsSensorArrayEntry(1) hhmsSensorArrayTemp(16)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) akcp(3854) hhmsagent(1) hhmsSensor(2) hhmsSensorArray(2) hhmsSensorArrayEntry(1) hhmsSensorArrayTempTable(16)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) akcp(3854) hhmsagent(1) hhmsSensor(2) hhmsSensorArray(2) hhmsSensorArrayEntry(1) hhmsSensorArrayTemp(16)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) akcp(3854) hhmsagent(1) hhmsSensor(2) hhmsSensorArrayTable(2) hhmsSensorArrayEntry(1) hhmsSensorArrayTempTable(16)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) akcp(3854) hhmsagent(1) hhmsSensor(2) hhmsSensorArrayTable(2) hhmsSensorArrayEntry(1) hhmsSensorArrayTemp(16)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) akcp(3854) hhmsagent(1) hhmsSensor(2) hhmsSensorArray(2) hhmsSensorArrayEntry(1) hhmsSensorArrayTempTable(16)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) akcp(3854) hhmsagent(1) hhmsSensor(2) hhmsSensorArray(2) hhmsSensorArrayEntry(1) hhmsSensorArrayTemp(16)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/akcp/hhmsagent/hhmsSensor/hhmsSensorArrayTable/hhmsSensorArrayEntry/hhmsSensorArrayTempTable
  • /iso/identified-organization/dod/internet/private/enterprise/akcp/hhmsagent/hhmsSensor/hhmsSensorArrayTable/hhmsSensorArrayEntry/hhmsSensorArrayTemp
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/akcp/hhmsagent/hhmsSensor/hhmsSensorArray/hhmsSensorArrayEntry/hhmsSensorArrayTempTable
  • /iso/org/dod/internet/private/enterprise/akcp/hhmsagent/hhmsSensor/hhmsSensorArray/hhmsSensorArrayEntry/hhmsSensorArrayTemp
  • /iso/org/dod/internet/private/enterprises/akcp/hhmsagent/hhmsSensor/hhmsSensorArrayTable/hhmsSensorArrayEntry/hhmsSensorArrayTempTable
  • /iso/org/dod/internet/private/enterprises/akcp/hhmsagent/hhmsSensor/hhmsSensorArrayTable/hhmsSensorArrayEntry/hhmsSensorArrayTemp
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/akcp/hhmsagent/hhmsSensor/hhmsSensorArray/hhmsSensorArrayEntry/hhmsSensorArrayTempTable
  • /iso/iso-identified-organization/dod/internet/private/enterprises/akcp/hhmsagent/hhmsSensor/hhmsSensorArray/hhmsSensorArrayEntry/hhmsSensorArrayTemp
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/3854/1/2/2/1/16

    Description by mibdepot

    This table contains the data for every Temperature Sensor in the SensorArray. Each row in the table contains data for a different Temperature Sensor.

    Parsed from file sa.mib.txt
    Company: None
    Module: HHMSAGENT-MIB

    Description by circitor

    This table contains the data for every Temperature Sensor in the SensorArray. Each row in the table contains data for a different Temperature Sensor.

    Parsed from file HHMSSMALL-MIB.mib
    Module: HHMSSMALL-MIB

    Information by oid_info

    Vendor: AKCP
    Module: HHMSAGENT-MIB (sa.mib)
    Type: TABLE
    Access: not-accessible
    Syntax: SEQUENCE OF

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    hhmsSensorArrayTempTable OBJECT-TYPE SYNTAX SEQUENCE OF HhmsSensorArrayTempEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the data for every Temperature Sensor in the SensorArray. Each row in the table contains data for a different Temperature Sensor." ::= { hhmsSensorArrayEntry 16 }

    Information by circitor

    hhmsSensorArrayTemp OBJECT IDENTIFIER ::= { hhmsSensorArrayEntry 16 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.3854)

    Klein Brad

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.3854.1.2.2.1.16.1 hhmsSensorArrayTempEntry 66 68 This is an entry in the hhmsSensorArrayTempEntry Table

    Brothers (95)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.3854.1.2.2.1.1 hhmsSensorArrayHost 1 1 The Host of this sensor, this is the IP address
    1.3.6.1.4.1.3854.1.2.2.1.2 hhmsSensorArrayUseDHCP 1 1 To use DHCP enter a 1, to use a static IP address enter a 2
    1.3.6.1.4.1.3854.1.2.2.1.3 hhmsSensorArrayMAC 1 1 The MAC address of this sensor.
    1.3.6.1.4.1.3854.1.2.2.1.4 hhmsSensorArraySetCommunity 1 1 The sensorArray community string used for snmp Sets
    1.3.6.1.4.1.3854.1.2.2.1.5 hhmsSensorArrayGetCommunity 1 1 The sensorArray community string used for snmp Gets
    1.3.6.1.4.1.3854.1.2.2.1.6 hhmsSensorArrayDescription 1 1 A Description of this sensorArray
    1.3.6.1.4.1.3854.1.2.2.1.7 hhmsSensorArrayLocation 1 1 The description of the physical location of this sensorArray
    1.3.6.1.4.1.3854.1.2.2.1.8 hhmsSensorArrayLastUpdate 1 1 The last time the sensorArray was read
    1.3.6.1.4.1.3854.1.2.2.1.9 hhmsSensorArrayStatus 1 1 The current status of this sensorArray
    1.3.6.1.4.1.3854.1.2.2.1.10 hhmsSensorArrayOnline 1 1 If this sensorArray is currently online
    1.3.6.1.4.1.3854.1.2.2.1.11 hhmsSensorArrayGoOnline 1 1 To put online enter a 1, to take offline enter a 2
    1.3.6.1.4.1.3854.1.2.2.1.12 hhmsSensorArrayReadInterval 1 1 How many seconds between readings of this sensor
    1.3.6.1.4.1.3854.1.2.2.1.13 hhmsSensorArrayReceiveTimeout 1 1 How many seconds to wait to receive data from the sensor
    1.3.6.1.4.1.3854.1.2.2.1.14 hhmsSensorArrayReceiveRetries 1 1 How many times to retry to receive data before giving up. A -1 means never give up trying
    1.3.6.1.4.1.3854.1.2.2.1.15 hhmsSensorArrayVersion 1 1 The version of this SensorArray
    1.3.6.1.4.1.3854.1.2.2.1.17 hhmsSensorArrayHumidityTable, hhmsSensorArrayHumidity 1 57 This table contains the data for every Humidity Sensor in the SensorArray. Each row in the table contains data for a different …
    1.3.6.1.4.1.3854.1.2.2.1.18 hhmsSensorArraySwitchTable, hhmsSensorArraySwitch 1 52 hhmsSensorArraySwitchtable
    1.3.6.1.4.1.3854.1.2.2.1.19 hhmsSensorArraySerialTable 13 931 This table contains the data for every Serial Port in the SensorArray. Each row in the table contains data for a different Seri…
    1.3.6.1.4.1.3854.1.2.2.1.20 hhmsSensorArrayDebug 1 1 Turn on or off debug messages
    1.3.6.1.4.1.3854.1.2.2.1.21 hhmsSensorArrayDebugIP 1 1 The IP address to send debug messages to
    1.3.6.1.4.1.3854.1.2.2.1.22 hhmsSensorArrayTrapResend 1 1 If traps for Warning or Error should be resent. Traps for Normal status are sent once
    1.3.6.1.4.1.3854.1.2.2.1.23 hhmsSensorArrayTrapResendInterval 1 1 How often to resend mail or Traps. Enter the number of seconds from 15 to 65535. Mail for WARNING and ERROR are resent at this …
    1.3.6.1.4.1.3854.1.2.2.1.24 hhmsSensorArraySendTraps 1 1 Turn on or off the sending of traps
    1.3.6.1.4.1.3854.1.2.2.1.25 hhmsSensorArrayTrapDestination 1 1 The IP address of the trap destination
    1.3.6.1.4.1.3854.1.2.2.1.26 hhmsSensorArrayTrapCommunity 1 1 The community string of the trap destination
    1.3.6.1.4.1.3854.1.2.2.1.27 hhmsSensorArrayTrapDefaultGateway 1 1 If the trap destination is on another network, enter the IP address of the router
    1.3.6.1.4.1.3854.1.2.2.1.28 hhmsSensorArrayTrapUseDefaultGateway 1 1 If the trap destination uses the default gateway
    1.3.6.1.4.1.3854.1.2.2.1.29 hhmsSensorArrayTrapDestinationMac 1 1 If the trap destination MAC address
    1.3.6.1.4.1.3854.1.2.2.1.30 hhmsSensorArraySendMail 1 1 Turn on or off the sending of Mail
    1.3.6.1.4.1.3854.1.2.2.1.31 hhmsSensorArrayMailRecpt 1 1 The email address of the Recipient
    1.3.6.1.4.1.3854.1.2.2.1.32 hhmsSensorArrayMailFrom 1 1 The email address of the Sender
    1.3.6.1.4.1.3854.1.2.2.1.33 hhmsSensorArrayMailSmpt 1 1 The IP Address of the SMPT server. Note: This must be in dotted decimal form
    1.3.6.1.4.1.3854.1.2.2.1.34 hhmsSensorArrayMailGateway 1 1 If the smpt server is on another network, enter the IP address of the router
    1.3.6.1.4.1.3854.1.2.2.1.35 hhmsSensorArrayMailUseGateway 1 1 If the mail uses the default gateway
    1.3.6.1.4.1.3854.1.2.2.1.36 hhmsSensorArrayMailResendInterval 1 1 How often to resend mail or Traps. Enter the number of seconds from 10 to 65535. Mail for WARNING and ERROR are resent at this …
    1.3.6.1.4.1.3854.1.2.2.1.37 hhmsSensorArrayMailMaxResend 1 1 The maximum number of times to resend mail. If set to 0 only send once. The maximum value is 25
    1.3.6.1.4.1.3854.1.2.2.1.38 hhmsSensorArrayMailDestinationMac 1 1 If the mail destination MAC address, either the smpt server or the gateway
    1.3.6.1.4.1.3854.1.2.2.1.39 hhmsSensorArrayMailLastStatus 1 1 The status of the most recent attempt to send an email
    1.3.6.1.4.1.3854.1.2.2.1.40 hhmsSensorArrayPowerControlTable 1 9 This table contains the Power Control features in the sensorArray.
    1.3.6.1.4.1.3854.1.2.2.1.41 hhmsSensorArrayPowerMonitorTable 1 14 This table contains the Power Monitor features in the sensorArray.
    1.3.6.1.4.1.3854.1.2.2.1.42 hhmsSensorArrayHighDriveTable 1 17 This table contains the High Current Drivers in the sensorArray.
    1.3.6.1.4.1.3854.1.2.2.1.43 hhmsSensorArrayCameraTable 1 8 This table contains the Camera features in the sensorArray.
    1.3.6.1.4.1.3854.1.2.2.1.50 hhmsSensorArrayTrapMailPollInterval 1 1 How often the sensor thresholds are tested before sending traps or mail. This can vary from 3 to 15 seconds
    1.3.6.1.4.1.3854.1.2.2.1.51 hhmsSensorArraySendTestMail 1 1 Send out an email test message
    1.3.6.1.4.1.3854.1.2.2.1.52 hhmsSensorArrayLastSystemError 1 1 A text string containing the description of the last system error
    1.3.6.1.4.1.3854.1.2.2.1.53 hhmsSensorArrayDataCollectionPeriod 1 1 The number of minutes between collections of the data logger. This can vary from 1 to 60 minutes
    1.3.6.1.4.1.3854.1.2.2.1.54 hhmsSensorArrayMailTimeout 1 1 The number of seconds to wait for a timeout while sending email This can vary from 10 to 60 seconds
    1.3.6.1.4.1.3854.1.2.2.1.55 sensorProbeAutoSense 0 0 sensorProbeAutoSense OBJECT-TYPE
    SYNTAX INTEGER {
    disable(0),
    enable(1)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "Enabl…
    1.3.6.1.4.1.3854.1.2.2.1.56 sensorProbeChecksum 0 0 sensorProbeChecksum OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
    "SP Only: The Flash Checksum, comp…
    1.3.6.1.4.1.3854.1.2.2.1.57 sensorProbeUsePassword 0 0 sensorProbeUsePassword OBJECT-TYPE
    SYNTAX INTEGER {
    usePassword(0),
    doNotUsePassword(1)
    }
    ACCESS read-write
    STATUS mandatory
    DE…
    1.3.6.1.4.1.3854.1.2.2.1.59 sensorProbeDisplayLogo 0 0 sensorProbeDisplayLogo OBJECT-TYPE
    SYNTAX INTEGER {
    disable(0),
    enable(1)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "Ena…
    1.3.6.1.4.1.3854.1.2.2.1.60 sensorProbeTrapType 0 0 sensorProbeTrapType OBJECT-TYPE
    SYNTAX INTEGER {
    specificTypeTrap(1),
    generalTypeTrap(2),
    bothtypeTraps(3),
    statusTypeTraps(4)
    1.3.6.1.4.1.3854.1.2.2.1.61 sensorProbeMailCC 0 0 sensorProbeMailCC OBJECT-TYPE
    SYNTAX DisplayString
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The email address of the CC"
    1.3.6.1.4.1.3854.1.2.2.1.62 sensorProbeAllowIPChange 0 0 sensorProbeAllowIPChange OBJECT-TYPE
    SYNTAX INTEGER {
    enable(1),
    disable(2)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "T…
    1.3.6.1.4.1.3854.1.2.2.1.65 sensorProbeTimeOfDay 0 0 sensorProbeTimeOfDay OBJECT-TYPE
    SYNTAX DisplayString
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The time of day in the fo…
    1.3.6.1.4.1.3854.1.2.2.1.66 sensorProbeEnableSysLog 0 0 sensorProbeEnableSysLog OBJECT-TYPE
    SYNTAX INTEGER {
    enableLogToFlash(1),
    enableLogToNetAndFlash(2),
    disable(3)
    }
    ACCESS read-w…
    1.3.6.1.4.1.3854.1.2.2.1.67 sensorProbeReadSysLog 0 0 sensorProbeReadSysLog OBJECT-TYPE
    SYNTAX INTEGER {
    lastMessage(1),
    allMessages(2)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPT…
    1.3.6.1.4.1.3854.1.2.2.1.68 sensorProbeClearSysLog 0 0 sensorProbeClearSysLog OBJECT-TYPE
    SYNTAX INTEGER {
    allMessages(2)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "Delete all…
    1.3.6.1.4.1.3854.1.2.2.1.69 sensorProbeSyslogDestIP 0 0 sensorProbeSyslogDestIP OBJECT-TYPE
    SYNTAX IpAddress
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The IP Address of the Sysl…
    1.3.6.1.4.1.3854.1.2.2.1.70 sensorProbeSyslogPort 0 0 sensorProbeSyslogPort OBJECT-TYPE
    SYNTAX Gauge
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The Port Number of the Syslog se…
    1.3.6.1.4.1.3854.1.2.2.1.71 sensorProbeSetSyslogMsgPrefix 0 0 sensorProbeSetSyslogMsgPrefix OBJECT-TYPE
    SYNTAX DisplayString
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "SP Only: The Pre…
    1.3.6.1.4.1.3854.1.2.2.1.81 sensorProbeTimeZone 0 0 sensorProbeTimeZone OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "System time zone"
    1.3.6.1.4.1.3854.1.2.2.1.83 sensorProbeMegaVersion 0 0 sensorProbeMegaVersion OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
    "Version number of mega board"
    1.3.6.1.4.1.3854.1.2.2.1.84 sensorProbeNtpMode 0 0 sensorProbeNtpMode OBJECT-TYPE
    SYNTAX INTEGER {
    notUse(0),
    oneTime(1),
    onSystemStartUp(2),
    onceAMounth(3),
    onceAWeek(4),
    onceAD…
    1.3.6.1.4.1.3854.1.2.2.1.85 sensorProbeNtpServer 0 0 sensorProbeNtpServer OBJECT-TYPE
    SYNTAX DisplayString
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "NTP server which this mac…
    1.3.6.1.4.1.3854.1.2.2.1.87 sensorProbeSMTPAuth 0 0 sensorProbeSMTPAuth OBJECT-TYPE
    SYNTAX INTEGER {
    enable(1),
    disable(2)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "This e…
    1.3.6.1.4.1.3854.1.2.2.1.88 sensorProbeSMTPLogin 0 0 sensorProbeSMTPLogin OBJECT-TYPE
    SYNTAX DisplayString
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The username used to logi…
    1.3.6.1.4.1.3854.1.2.2.1.89 sensorProbeSMTPPassword 0 0 sensorProbeSMTPPassword OBJECT-TYPE
    SYNTAX DisplayString
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The password used to l…
    1.3.6.1.4.1.3854.1.2.2.1.90 sensorProbeDNSServer 0 0 sensorProbeDNSServer OBJECT-TYPE
    SYNTAX IpAddress
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "IP address of the DNS server"
    1.3.6.1.4.1.3854.1.2.2.1.91 sensorProbeAltWebPort 0 0 sensorProbeAltWebPort OBJECT-TYPE
    SYNTAX Gauge
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "The alternative for a port numbe…
    1.3.6.1.4.1.3854.1.2.2.1.92 sensorProbeNumberOfSensorPort 0 0 sensorProbeNumberOfSensorPort OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
    "The number of sensor po…
    1.3.6.1.4.1.3854.1.2.2.1.93 sensorProbeSendTrapsAlive 0 0 sensorProbeSendTrapsAlive OBJECT-TYPE
    SYNTAX INTEGER {
    on(1),
    off(2)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "On or of…
    1.3.6.1.4.1.3854.1.2.2.1.94 sensorProbeTrapReIntervalAlive 0 0 sensorProbeTrapReIntervalAlive OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "Time between each kee…
    1.3.6.1.4.1.3854.1.2.2.1.95 sensorProbeUseCamera 0 0 sensorProbeUseCamera OBJECT-TYPE
    SYNTAX INTEGER {
    off(0),
    on(1)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "On or off cam…
    1.3.6.1.4.1.3854.1.2.2.1.96 sensorProbeAdcCalibratePort 0 0 sensorProbeAdcCalibratePort OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "Calibrate value for anal…
    1.3.6.1.4.1.3854.1.2.2.1.98 sensorProbeMailSubject 0 0 sensorProbeMailSubject OBJECT-TYPE
    SYNTAX DisplayString
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "Email Subject."
    1.3.6.1.4.1.3854.1.2.2.1.99 sensorProbeSnmpPort 0 0 sensorProbeSnmpPort OBJECT-TYPE
    SYNTAX Gauge
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "SP Only: Port number used to acces…
    1.3.6.1.4.1.3854.1.2.2.1.100 sensorProbeSnmpTrapPort 0 0 sensorProbeSnmpTrapPort OBJECT-TYPE
    SYNTAX Gauge
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "SP Only: Port number used to a…
    1.3.6.1.4.1.3854.1.2.2.1.101 sensorProbeSnmpIndexingMode 0 0 sensorProbeSnmpIndexingMode OBJECT-TYPE
    SYNTAX INTEGER {
    index0(0),
    index1(1)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    1.3.6.1.4.1.3854.1.2.2.1.103 sensorProbeNotifyBoot 0 0 sensorProbeNotifyBoot OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "SP2 Only: Enable Notify on boo…
    1.3.6.1.4.1.3854.1.2.2.1.104 sensorProbeDelayNotifyBoot 0 0 sensorProbeDelayNotifyBoot OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "SP2 Only: Delay time for …
    1.3.6.1.4.1.3854.1.2.2.1.105 sensorProbeSmtpPort 0 0 sensorProbeSmtpPort OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "SMTP Port number used to send em…
    1.3.6.1.4.1.3854.1.2.2.1.106 sensorProbeReboot 0 0 sensorProbeReboot OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "Reboot SP2/SP8 set to 1"
    1.3.6.1.4.1.3854.1.2.2.1.107 sensorProbeServerEnable 0 0 sensorProbeServerEnable OBJECT-TYPE
    SYNTAX INTEGER {
    disable(0),
    enable(1)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "En…
    1.3.6.1.4.1.3854.1.2.2.1.108 sensorProbeFirmwareVersion 0 0 sensorProbeFirmwareVersion OBJECT-TYPE
    SYNTAX DisplayString
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
    "Current firmware ver…
    1.3.6.1.4.1.3854.1.2.2.1.109 sensorProbeProductType 0 0 sensorProbeProductType OBJECT-TYPE
    SYNTAX INTEGER {
    sensorProbe2(1),
    sensorProbe8(2),
    sensorProbeLinuxWithoutUSB(3),
    sensorProb…
    1.3.6.1.4.1.3854.1.2.2.1.110 sensorProbeRequestResendTrap 0 0 sensorProbeRequestResendTrap OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "SP only: Send immediate…
    1.3.6.1.4.1.3854.1.2.2.1.112 sensorProbeSeparateEmail 0 0 sensorProbeSeparateEmail OBJECT-TYPE
    SYNTAX INTEGER {
    notSeparate(0),
    separate(1)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPT…
    1.3.6.1.4.1.3854.1.2.2.1.113 sensorProbeMailCustom 0 0 sensorProbeMailCustom OBJECT-TYPE
    SYNTAX INTEGER {
    normal(0),
    custom(1)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "SP on…
    1.3.6.1.4.1.3854.1.2.2.1.114 sensorProbeUntidePassword 0 0 sensorProbeUntidePassword OBJECT-TYPE
    SYNTAX INTEGER {
    tidePassword(0),
    untidePassword(1)
    }
    ACCESS read-write
    STATUS mandatory
    1.3.6.1.4.1.3854.1.2.2.1.115 sensorProbeWebPassword 2 2 None
    1.3.6.1.4.1.3854.1.2.2.1.116 sensorProbeReloadNetwork 0 0 sensorProbeReloadNetwork OBJECT-TYPE
    SYNTAX INTEGER {
    reload(1)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
    "Set 1 for rel…
    1.3.6.1.4.1.3854.1.2.2.1.117 sensorProbeStatusNumber 3 3 None
    1.3.6.1.4.1.3854.1.2.2.1.118 sensorProbeTypeName 34 34 None
    1.3.6.1.4.1.3854.1.2.2.1.119 sensorProbeProductRevision 0 0 sensorProbeProductRevision OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
    "SP only: Revision number"