This parameters identifies the type of chassis that this
node is residing in. This is necessary in order to correctly
interpret the fan and power supply status signals.
newvalStandalone : same functionality as 'standalone', new
enumeration added for RFC1155 compatibility.
Parsed from file vanguard-65xx-cdx_6500.mib.txt
Company: None
Module: CDX-6500-COMMON-MIB
This parameters identifies the type of chassis that this
node is residing in. This is necessary in order to correctly
interpret the fan and power supply status signals.
newvalStandalone : same functionality as 'standalone', new
enumeration added for RFC1155 compatibility.
Parsed from file CDX-6500-COMMON-MIB.mib
Module: CDX-6500-COMMON-MIB
Vendor: Codex
Module: CDX-6500-COMMON-MIB
[Automatically extracted from oidview.com]
cdx6500NMNPCchassis OBJECT-TYPE SYNTAX INTEGER { standalone (0), modulus8 (1), modulus18 (2), modulus9 (3), modulus19 (4), chassis6520 (5), chassis6560 (6), newvalStandalone (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameters identifies the type of chassis that this node is residing in. This is necessary in order to correctly interpret the fan and power supply status signals. newvalStandalone : same functionality as 'standalone', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPconfig 4 }
cdx6500NMNPCchassis OBJECT-TYPE SYNTAX INTEGER { standalone (0), modulus8 (1), modulus18 (2), modulus9 (3), modulus19 (4), chassis6520 (5), chassis6560 (6), newvalStandalone (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameters identifies the type of chassis that this node is residing in. This is necessary in order to correctly interpret the fan and power supply status signals. newvalStandalone : same functionality as 'standalone', new enumeration added for RFC1155 compatibility." ::= { cdx6500NMNPconfig 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.449.2.1.1.2.1.4.0 | cdx6500NMNPCchassis | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.449.2.1.1.2.1.1 | cdx6500NMNPCnodeName | 1 | 1 | This parameter identifies the node with a name, which appears at the top of control terminal menus and reports. Range is 0 to 8 a… |
1.3.6.1.4.1.449.2.1.1.2.1.2 | cdx6500NMNPCnodeNum | 1 | 1 | The node number identifies the node for X.25 routing purposes to prevent routing loops. |
1.3.6.1.4.1.449.2.1.1.2.1.3 | cdx6500NMNPCnodeAddress | 1 | 1 | The node address specifies the main part of the network address for calls destined within this node: PAD port or node resource (f… |
1.3.6.1.4.1.449.2.1.1.2.1.5 | cdx6500NMNPCdate | 1 | 1 | The node date used for date stamps of events and traps. The format of the string is yyyymmmdd, year: four digits, month: first th… |
1.3.6.1.4.1.449.2.1.1.2.1.6 | cdx6500NMNPCtime | 1 | 1 | The node time used for time stamps of events and traps. The format of the string is hhmmss, hour: 00..23, minute 00..59, second: … |
1.3.6.1.4.1.449.2.1.1.2.1.7 | cdx6500NMNPCportUtil | 1 | 1 | Port Utilization Threshold (%). This parameter sets the alarm level for traffic on every port in a node. The traffic is checked o… |
1.3.6.1.4.1.449.2.1.1.2.1.8 | cdx6500NMNPCbuffUtil | 1 | 1 | Buffer Utilization Threshold (%). This parameter sets the alarm level for data buffers. When data passes through a node, buffers … |
1.3.6.1.4.1.449.2.1.1.2.1.9 | cdx6500NMNPCcpuUtil | 1 | 1 | CPU Utilization Threshold (%). If the CPU is not processing data, it is running diagnostic checks. It is never idle. This paramet… |
1.3.6.1.4.1.449.2.1.1.2.1.10 | cdx6500NMNPCportErr | 1 | 1 | Port Error Threshold. This threshold specifies the number of port errors (such as parity or framing errors) that can be detected … |
1.3.6.1.4.1.449.2.1.1.2.1.11 | cdx6500NMNPCalarmTmr | 1 | 1 | Alarm Threshold Timer. This parameter prevents a node from sending threshold alarms too frequently. If a node generates an alarm … |
1.3.6.1.4.1.449.2.1.1.2.1.12 | cdx6500NMNPCmaxRoutHops | 1 | 1 | Maximum Routing Hops.This parameter specifies the maximum number of nodes a call may pass through before reaching its destination. |
1.3.6.1.4.1.449.2.1.1.2.1.13 | cdx6500NMNPCctpSubAddr | 1 | 1 | This parameter specifies the Control Port (CTP) Subaddress. Calls with network address composed of the node address and this suba… |
1.3.6.1.4.1.449.2.1.1.2.1.14 | cdx6500NMNPCctpIdleTime | 1 | 1 | Control Port Idle Disconnect Time (minutes). This specifies how many minutes of inactivity can occur before the control terminal … |
1.3.6.1.4.1.449.2.1.1.2.1.15 | cdx6500NMNPCalmDist | 1 | 1 | This object has been replaced by cdx6500NMNPCalmDistrib. |
1.3.6.1.4.1.449.2.1.1.2.1.16 | cdx6500NMNPCalmMmem | 1 | 1 | Alarm Printer Mnemonic. This specifies the mnemonic name for the destination of alarms sent by the node (if Alarm Distribution = … |
1.3.6.1.4.1.449.2.1.1.2.1.17 | cdx6500NMNPCalmSelect | 1 | 1 | This object has been replaced by cdx6500NMNPCalmSelection. |
1.3.6.1.4.1.449.2.1.1.2.1.18 | cdx6500NMNPCbroadPortSubad | 1 | 1 | This specifies the broadcast port subaddress for this node. Calls with network address composed of the node address and this suba… |
1.3.6.1.4.1.449.2.1.1.2.1.19 | cdx6500NMNPCnoBroadNets | 1 | 1 | Number of Broadcast Nets. This specifies the number of Broadcast Networks to which this node can send broadcast messages. A value… |
1.3.6.1.4.1.449.2.1.1.2.1.20 | cdx6500NMNPCnoBroadInCh | 1 | 1 | Number of Broadcast Input Channels. This specifies the number of simultaneous broadcast messages that can be received. |
1.3.6.1.4.1.449.2.1.1.2.1.21 | cdx6500NMNPCbillMnem | 1 | 1 | When billing records need to be printed, the node will use this mnemonic to call and send the records to this destination. This … |
1.3.6.1.4.1.449.2.1.1.2.1.22 | cdx6500NMNPCbillThresh | 1 | 1 | When the number of billing records queued up equals this threshold, a call will be placed to the logging device to dump the billi… |
1.3.6.1.4.1.449.2.1.1.2.1.23 | cdx6500NMNPCmaxBill | 1 | 1 | This is the maximum number of billing records the node will be allowed to store to be printed. Billing records created after this… |
1.3.6.1.4.1.449.2.1.1.2.1.24 | cdx6500NMNPCbillTimer | 1 | 1 | If billing records have been stored for printing for this amount of time (in minutes) without reaching the threshold, a call will… |
1.3.6.1.4.1.449.2.1.1.2.1.25 | cdx6500NMNPCpvcBill | 1 | 1 | At this interval the billing records will be gathered and printed for all of the PVC's in the node that have billing turned on. |
1.3.6.1.4.1.449.2.1.1.2.1.26 | cdx6500NMNPCmaxCalls | 1 | 1 | Limiting the number of calls allowed in the node will eliminate data loss in extreme traffic conditions. |
1.3.6.1.4.1.449.2.1.1.2.1.27 | cdx6500NMNPCpadBulletin | 1 | 1 | PAD Bulletin Message. Specifies the message that appears when a terminal connects to PAD port and enters Command Mode. To have no… |
1.3.6.1.4.1.449.2.1.1.2.1.28 | cdx6500NMNPCpadBanner | 1 | 1 | PAD Banner Message. Specifies the message PAD ports send to attached terminals when they enter Command Mode. These special charac… |
1.3.6.1.4.1.449.2.1.1.2.1.29 | cdx6500NMNPCdcpFac | 1 | 1 | This defines the facility used to carry DCP information at call setup and reconnection time in Call Request and Call Accept packe… |
1.3.6.1.4.1.449.2.1.1.2.1.30 | cdx6500NMNPCtrafficPri | 1 | 1 | Traffic Priority. This is the default traffic priority to be used on the node. newvalLow : same functionality as 'low', new enumer… |
1.3.6.1.4.1.449.2.1.1.2.1.31 | cdx6500NMNPCtrafficStep | 1 | 1 | Traffic Priority Step. This specifies the number of packets to be transmitted for each lower priority packet transmitted. |
1.3.6.1.4.1.449.2.1.1.2.1.32 | cdx6500NMNPCpropProtId | 1 | 1 | This is the Codex Proprietary Protocol ID. Its value is put in the first byte of the Protocol Identifier field of the CUD in the … |
1.3.6.1.4.1.449.2.1.1.2.1.33 | cdx6500NMNPClanSubAddr | 1 | 1 | Calls with network address composed of the node address and this subaddress will be routed to a LAN Connection in this node. |
1.3.6.1.4.1.449.2.1.1.2.1.34 | cdx6500NMNPCMaxFrameSize | 1 | 1 | The largest datalink level frame that will ever be received on any link. On WAN links this does not include space that is reserve… |
1.3.6.1.4.1.449.2.1.1.2.1.35 | cdx6500NMNPCCodexGroupFacility | 1 | 1 | This is the facility used in call packets on Codex 6500 links for passing CODEX PRIVATE facilities other than Hop Count and DCP fa… |
1.3.6.1.4.1.449.2.1.1.2.1.36 | cdx6500NMNPCalmDistrib | 1 | 1 | Distribution of alarms is controlled by specifying: NONE - no alarm is sent\r\n\ CTP - send alarms to Control Port Terminal\r\n\… |
1.3.6.1.4.1.449.2.1.1.2.1.37 | cdx6500NMNPCalmSelection | 1 | 1 | Alarm type reporting by the node: NONE - no alarms reported. HIGH - high severity alarms reported. MED - medium severity alarms r… |
1.3.6.1.4.1.449.2.1.1.2.1.38 | cdx6500NMNPChopFacility | 1 | 1 | Hop Count Facility. This is the facility used in call packets on X.25 links with the INL option for network routing. This should … |
1.3.6.1.4.1.449.2.1.1.2.1.39 | cdx6500NMNPCnumNccpDevices | 1 | 1 | This is the number of NCCP devices. |
1.3.6.1.4.1.449.2.1.1.2.1.40 | cdx6500NMNPCmaxCallid | 1 | 1 | This is the maximum number of Call id numbers that go in the Calling Identifier table. This table can have a maximum of 512 entri… |