This specifies how the switched service/backup port
will be activated.
fail - Activate the backup port upon link failure.
call - Activate the backup port upon a call request.
either - Activate the backup port upon link
failure or a call request.
newvalFail - same functionality as 'fail', new enumeration
added for RFC1155 compatibility.
Parsed from file vanguard-65xx-ss.mib.txt
Company: None
Module: SS-OPT-MIB
This specifies how the switched service/backup port
will be activated.
fail - Activate the backup port upon link failure.
call - Activate the backup port upon a call request.
either - Activate the backup port upon link
failure or a call request.
newvalFail - same functionality as 'fail', new enumeration
added for RFC1155 compatibility.
Parsed from file SS-OPT-MIB.mib
Module: SS-OPT-MIB
Vendor: Codex
Module: SS-OPT-MIB
[Automatically extracted from oidview.com]
cdx6500SSActivationMode OBJECT-TYPE SYNTAX INTEGER { fail (0), call (1), either (2), newvalFail (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies how the switched service/backup port will be activated. fail - Activate the backup port upon link failure. call - Activate the backup port upon a call request. either - Activate the backup port upon link failure or a call request. newvalFail - same functionality as 'fail', new enumeration added for RFC1155 compatibility." ::= { cdx6500SSCfgEntry 6 }
cdx6500SSActivationMode OBJECT-TYPE SYNTAX INTEGER { fail (0), call (1), either (2), newvalFail (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This specifies how the switched service/backup port will be activated. fail - Activate the backup port upon link failure. call - Activate the backup port upon a call request. either - Activate the backup port upon link failure or a call request. newvalFail - same functionality as 'fail', new enumeration added for RFC1155 compatibility." ::= { cdx6500SSCfgEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.449.2.1.2.2.14.1.1 | cdx6500SSEntryNumber | 0 | 0 | This identifies the particular Switched Service/LBU Table entry being configured. The number of instances defined by this entry d… |
1.3.6.1.4.1.449.2.1.2.2.14.1.2 | cdx6500SSDestinationName | 0 | 0 | This is a unique name that identifies this entry. |
1.3.6.1.4.1.449.2.1.2.2.14.1.3 | cdx6500SSCfgMonitoredPort | 0 | 0 | The X.25 port to be monitored for link failure. This is the port whose calls are rerouted in the event of port failure. The forma… |
1.3.6.1.4.1.449.2.1.2.2.14.1.4 | cdx6500SSCfgRestoralPort | 0 | 0 | This is the port or channel that acts as the backup when there is a port failure on the port specified by the parameter Monitored… |
1.3.6.1.4.1.449.2.1.2.2.14.1.5 | cdx6500SSDialSequence | 0 | 0 | This specifies the telephone numbers that will be dialed when the backup port is activated. To enter your own telephone number, u… |
1.3.6.1.4.1.449.2.1.2.2.14.1.7 | cdx6500SSDeactivationMode | 0 | 0 | This specifies how the switched service/backup port is deactivated after the original link is up. none - Backup port can only… |
1.3.6.1.4.1.449.2.1.2.2.14.1.8 | cdx6500SSLinkHoldTime | 0 | 0 | This replaces the value of the parameter Idle Disconnect Timer in the X.25 Port Record and specifies how long (in seconds) the ba… |
1.3.6.1.4.1.449.2.1.2.2.14.1.9 | cdx6500SSOutBoundPass | 0 | 0 | This is the password used by the remote station to determine if dial access is authorized. |
1.3.6.1.4.1.449.2.1.2.2.14.1.10 | cdx6500SSRedialTime | 0 | 0 | This is the time in seconds between dial attempts when bringing up a switched service call. |
1.3.6.1.4.1.449.2.1.2.2.14.1.11 | cdx6500SSRedialCounter | 0 | 0 | This parameter is used to specify the number of times that the Switched Service will attempt to redial when redial timer is expir… |
1.3.6.1.4.1.449.2.1.2.2.14.1.12 | cdx6500SSSecurityMode | 0 | 0 | This specifies under what conditions the port/channel authorizes call request. none - A call request not be rejected based … |
1.3.6.1.4.1.449.2.1.2.2.14.1.13 | cdx6500SSSetupTime | 0 | 0 | This is the time in seconds the monitor port(s) are given to come up after node boot before the backup port is activated. |
1.3.6.1.4.1.449.2.1.2.2.14.1.14 | cdx6500SSCfgMonitoredPort2 | 0 | 0 | The X.25 port to be monitored for link failure. This is the port whose calls are rerouted in the event of port failure. The forma… |
1.3.6.1.4.1.449.2.1.2.2.14.1.15 | cdx6500SSCfgMonitoredPort3 | 0 | 0 | The X.25 port to be monitored for link failure. This is the port whose calls are rerouted in the event of port failure. The forma… |
1.3.6.1.4.1.449.2.1.2.2.14.1.16 | cdx6500SSCfgMonitoredPort4 | 0 | 0 | The X.25 port to be monitored for link failure. This is the port whose calls are rerouted in the event of port failure. The forma… |
1.3.6.1.4.1.449.2.1.2.2.14.1.17 | cdx6500SSDialSequence2 | 0 | 0 | This specifies the telephone numbers that will be dialed when the backup port is activated. To enter your own telephone number, u… |
1.3.6.1.4.1.449.2.1.2.2.14.1.18 | cdx6500SSDialSequence3 | 0 | 0 | This specifies the telephone numbers that will be dialed when the backup port is activated. To enter your own telephone number, u… |
1.3.6.1.4.1.449.2.1.2.2.14.1.19 | cdx6500SSDialSequence4 | 0 | 0 | This specifies the telephone numbers that will be dialed when the backup port is activated. To enter your own telephone number, u… |