The lineloop(2) selection places the
snmp540 into line loopback mode. The
noTest(1) and telcoLoop(5) are READ ONLY
values. NoTest(1) indicates that no
diagnostic test is in progress. The
value telcoLoop(5) will be reported
when a DSU/CSU test is initiated by
Telco. The value remoteLoop(3) is used
initiate a remote loopback test. The
value resetTestToNorm(4) will halt the
execution of diagnostic test that may be running.
Parsed from file SNMP540.mib.txt
Company: None
Module: SNMP540-MGMT-MIB
The lineloop(2) selection places the
snmp540 into line loopback mode. The
noTest(1) and telcoLoop(5) are READ ONLY
values. NoTest(1) indicates that no
diagnostic test is in progress. The
value telcoLoop(5) will be reported
when a DSU/CSU test is initiated by
Telco. The value remoteLoop(3) is used
initiate a remote loopback test. The
value resetTestToNorm(4) will halt the
execution of diagnostic test that may be running.
Parsed from file SNMP540-MGMT-MIB.mib
Module: SNMP540-MGMT-MIB
snmp540DiagControl OBJECT-TYPE SYNTAX INTEGER { noTest(1), lineloop(2), remoteLoop(3), resetTestToNorm(4), telcoLoop(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The lineloop(2) selection places the snmp540 into line loopback mode. The noTest(1) and telcoLoop(5) are READ ONLY values. NoTest(1) indicates that no diagnostic test is in progress. The value telcoLoop(5) will be reported when a DSU/CSU test is initiated by Telco. The value remoteLoop(3) is used initiate a remote loopback test. The value resetTestToNorm(4) will halt the execution of diagnostic test that may be running." ::= { snmp540DiagTest 7 }
Vendor: General DataComm, Inc.
Module: SNMP540-MGMT-MIB
[Automatically extracted from oidview.com]
snmp540DiagControl OBJECT-TYPE SYNTAX INTEGER { noTest(1), lineloop(2), remoteLoop(3), resetTestToNorm(4), telcoLoop(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The lineloop(2) selection places the snmp540 into line loopback mode. The noTest(1) and telcoLoop(5) are READ ONLY values. NoTest(1) indicates that no diagnostic test is in progress. The value telcoLoop(5) will be reported when a DSU/CSU test is initiated by Telco. The value remoteLoop(3) is used initiate a remote loopback test. The value resetTestToNorm(4) will halt the execution of diagnostic test that may be running." ::= { snmp540DiagTest 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.8.4.7.7.0 | snmp540DiagControl | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.8.4.7.1 | snmp540DiagTestPattern | 1 | 1 | The Self Test Pattern choices generated internally by the snmp540 are 511 Pattern (snmp540Send511Pattern(2)), 2047 pattern, (snmp5… |
1.3.6.1.4.1.498.8.4.7.2 | snmp540DiagTestExceptions | 1 | 1 | Indicates exceptions that have occurred that may affect interpretation of the test results. The exception values are: value excepti… |
1.3.6.1.4.1.498.8.4.7.3 | snmp540DiagBitErrors | 1 | 1 | The bit errors of the most recently run diagnostic test. If TestExceptions reports bitsOutOfRange, this object should be ignored. |
1.3.6.1.4.1.498.8.4.7.4 | snmp540DiagBlockErrors | 1 | 1 | The block errors of the most recently run diagnostic test. |
1.3.6.1.4.1.498.8.4.7.5 | snmp540RlLoopType | 1 | 1 | The value Pn127(1), will use a PN127 loopback sequence to initiate a remote loopback test. The value v54(2) will use a V54 loopba… |
1.3.6.1.4.1.498.8.4.7.6 | snmp540DiagBlocksToSend | 1 | 1 | Specifies the number of test pattern blocks to generate during the test. The requested number of blocks are sent and checked dur… |