The loopback configuration for the DSU channel to be used
for both active and passive diagnostic tests.
Parsed from file gdcdsu.mib.txt
Company: None
Module: GDC-DSU-MGMT-MIB
The loopback configuration for the DSU channel to be used
for both active and passive diagnostic tests.
Parsed from file GDC-DSU-MGMT-MIB.mib
Module: GDC-DSU-MGMT-MIB
gdcDsuChannelLoopbackConfig OBJECT-TYPE SYNTAX INTEGER { noLoop(1), localLoop(2), digitalLoop(3), rdl(4), rdlReset(5), otherLoop(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The loopback configuration for the DSU channel to be used for both active and passive diagnostic tests." ::= { gdcDsuChannelDiagEntry 4 }
Vendor: General DataComm, Inc.
Module: GDC-DSU-MGMT-MIB
[Automatically extracted from oidview.com]
gdcDsuChannelLoopbackConfig OBJECT-TYPE SYNTAX INTEGER { noLoop(1), localLoop(2), digitalLoop(3), rdl(4), rdlReset(5), otherLoop(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The loopback configuration for the DSU channel to be used for both active and passive diagnostic tests." ::= { gdcDsuChannelDiagEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.8.5.4.1.1 | gdcDsuChannelDiagIndex | 0 | 0 | The index value which uniquely identifies the channel to which this entry is applicable. This has the form of a SC instance whic… |
1.3.6.1.4.1.498.8.5.4.1.2 | gdcDsuChannelDiagSendCode | 0 | 0 | Initiates and terminates self test pattern generation and detection (active diagnostic tests) on the DSU channel. When this obj… |
1.3.6.1.4.1.498.8.5.4.1.3 | gdcDsuChannelDiagProgPattern | 0 | 0 | The 16 bit user programmable test pattern. This object works with gdcDsuChannelSendCode. When gdcDsuChannelSendCodeis set to sen… |
1.3.6.1.4.1.498.8.5.4.1.5 | gdcDsuChannelTestDuration | 0 | 0 | The length of the diagnostic test, in time. The value 0 signifies that the test should run indefinitely until explicitly terminat… |
1.3.6.1.4.1.498.8.5.4.1.6 | gdcDsuChannelDiagTimingSource | 0 | 0 | The timing source to be used for diagnostic tests. For tests that do not disrupt the transmit timing source as defined in gdcDsx1… |
1.3.6.1.4.1.498.8.5.4.1.7 | gdcDsuChannelTestStatus | 0 | 0 | The current execution status of the diagnostic test. The value testRunning(1) indicates that a diagnostic test is running. The va… |
1.3.6.1.4.1.498.8.5.4.1.8 | gdcDsuChannelTestExceptions | 0 | 0 | Indicates any exceptions that may have occurred that would affect the interpretation of the test results provided in gdcDsuChanne… |
1.3.6.1.4.1.498.8.5.4.1.9 | gdcDsuChannelTestResults | 0 | 0 | The results of the last diagnostic test, in bit errors. This can be the current test running or the last completed test. Note tha… |