The timing source to be used for diagnostic tests.
For tests that do not disrupt the transmit timing source as
defined in gdcDsx1TransmitClockSource the value currentSource(1)
should be used. The remaining timing sources are for use when
the diagnostic test disrupts the transmit timing source.
The choice of the diagnostic timing source is dependant upon
the type of test involved and the network topology.
Parsed from file gdcdsu.mib.txt
Company: None
Module: GDC-DSU-MGMT-MIB
The timing source to be used for diagnostic tests.
For tests that do not disrupt the transmit timing source as
defined in gdcDsx1TransmitClockSource the value currentSource(1)
should be used. The remaining timing sources are for use when
the diagnostic test disrupts the transmit timing source.
The choice of the diagnostic timing source is dependant upon
the type of test involved and the network topology.
Parsed from file GDC-DSU-MGMT-MIB.mib
Module: GDC-DSU-MGMT-MIB
gdcDsuChannelDiagTimingSource OBJECT-TYPE SYNTAX INTEGER { currentSource(1), loopTiming(2), localTiming(3), station(4), composite(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The timing source to be used for diagnostic tests. For tests that do not disrupt the transmit timing source as defined in gdcDsx1TransmitClockSource the value currentSource(1) should be used. The remaining timing sources are for use when the diagnostic test disrupts the transmit timing source. The choice of the diagnostic timing source is dependant upon the type of test involved and the network topology." ::= { gdcDsuChannelDiagEntry 6 }
Vendor: General DataComm, Inc.
Module: GDC-DSU-MGMT-MIB
[Automatically extracted from oidview.com]
gdcDsuChannelDiagTimingSource OBJECT-TYPE SYNTAX INTEGER { currentSource(1), loopTiming(2), localTiming(3), station(4), composite(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The timing source to be used for diagnostic tests. For tests that do not disrupt the transmit timing source as defined in gdcDsx1TransmitClockSource the value currentSource(1) should be used. The remaining timing sources are for use when the diagnostic test disrupts the transmit timing source. The choice of the diagnostic timing source is dependant upon the type of test involved and the network topology." ::= { gdcDsuChannelDiagEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.8.5.4.1.1 | gdcDsuChannelDiagIndex | 0 | 0 | The index value which uniquely identifies the channel to which this entry is applicable. This has the form of a SC instance whic… |
1.3.6.1.4.1.498.8.5.4.1.2 | gdcDsuChannelDiagSendCode | 0 | 0 | Initiates and terminates self test pattern generation and detection (active diagnostic tests) on the DSU channel. When this obj… |
1.3.6.1.4.1.498.8.5.4.1.3 | gdcDsuChannelDiagProgPattern | 0 | 0 | The 16 bit user programmable test pattern. This object works with gdcDsuChannelSendCode. When gdcDsuChannelSendCodeis set to sen… |
1.3.6.1.4.1.498.8.5.4.1.4 | gdcDsuChannelLoopbackConfig | 0 | 0 | The loopback configuration for the DSU channel to be used for both active and passive diagnostic tests. |
1.3.6.1.4.1.498.8.5.4.1.5 | gdcDsuChannelTestDuration | 0 | 0 | The length of the diagnostic test, in time. The value 0 signifies that the test should run indefinitely until explicitly terminat… |
1.3.6.1.4.1.498.8.5.4.1.7 | gdcDsuChannelTestStatus | 0 | 0 | The current execution status of the diagnostic test. The value testRunning(1) indicates that a diagnostic test is running. The va… |
1.3.6.1.4.1.498.8.5.4.1.8 | gdcDsuChannelTestExceptions | 0 | 0 | Indicates any exceptions that may have occurred that would affect the interpretation of the test results provided in gdcDsuChanne… |
1.3.6.1.4.1.498.8.5.4.1.9 | gdcDsuChannelTestResults | 0 | 0 | The results of the last diagnostic test, in bit errors. This can be the current test running or the last completed test. Note tha… |