To initiate a Dataloop with Selftest SET this object and specifiy a
blocksize. The nms510 (the remote) unit will go into Dataloop and
the master (the sc5520) unit will go into Selftest. The blocksize
indicates the number of blocks the Selftest pattern generator will run.
There are 1000 bits/block. Emuns 3 through 10 are write only.
The only valid responses to a READ are dataloopOn(2) or dataloopOff(1).
This test will terminate after the specified number of blocks have been run.
Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors
objects while the test is running will cause the test to terminate
prematurely and render the results invalid. Test results should be read
only after the test is completed and are available from the master (sc5520)
unit. The current Test Status can be obtained by reading the
sc5520DiagTestStatus object on the master unit, reading test status on the
remote unit may interfere with the diagonostic test pattern and cause errors.
This test can also be terminated by seting the nms510DiagTestReset object.
Parsed from file nms510.mib.txt
Company: None
Module: NMS510-MIB
To initiate a Dataloop with Selftest SET this object and specifiy a
blocksize. The nms510 (the remote) unit will go into Dataloop and
the master (the sc5520) unit will go into Selftest. The blocksize
indicates the number of blocks the Selftest pattern generator will run.
There are 1000 bits/block. Emuns 3 through 10 are write only.
The only valid responses to a READ are dataloopOn(2) or dataloopOff(1).
This test will terminate after the specified number of blocks have been run.
Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors
objects while the test is running will cause the test to terminate
prematurely and render the results invalid. Test results should be read
only after the test is completed and are available from the master (sc5520)
unit. The current Test Status can be obtained by reading the
sc5520DiagTestStatus object on the master unit, reading test status on the
remote unit may interfere with the diagonostic test pattern and cause errors.
This test can also be terminated by seting the nms510DiagTestReset object.
Parsed from file NMS510-MIB.mib
Module: NMS510-MIB
nms510DiagIntDataloop OBJECT-TYPE SYNTAX INTEGER { dataloopOff(1), dataloopOn(2), blocks1(3), blocks10(4), blocks100(5), blocks500(6), blocks1000(7), blocks5000(8), blocks10000(9), blocks50000(10) } ACCESS read-write STATUS mandatory DESCRIPTION "To initiate a Dataloop with Selftest SET this object and specifiy a blocksize. The nms510 (the remote) unit will go into Dataloop and the master (the sc5520) unit will go into Selftest. The blocksize indicates the number of blocks the Selftest pattern generator will run. There are 1000 bits/block. Emuns 3 through 10 are write only. The only valid responses to a READ are dataloopOn(2) or dataloopOff(1). This test will terminate after the specified number of blocks have been run. Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors objects while the test is running will cause the test to terminate prematurely and render the results invalid. Test results should be read only after the test is completed and are available from the master (sc5520) unit. The current Test Status can be obtained by reading the sc5520DiagTestStatus object on the master unit, reading test status on the remote unit may interfere with the diagonostic test pattern and cause errors. This test can also be terminated by seting the nms510DiagTestReset object. " ::= { nms510DiagExcEntry 3 }
Vendor: General DataComm, Inc.
Module: NMS510-MIB
[Automatically extracted from oidview.com]
nms510DiagIntDataloop OBJECT-TYPE SYNTAX INTEGER { dataloopOff(1), dataloopOn(2), blocks1(3), blocks10(4), blocks100(5), blocks500(6), blocks1000(7), blocks5000(8), blocks10000(9), blocks50000(10) } ACCESS read-write STATUS mandatory DESCRIPTION "To initiate a Dataloop with Selftest SET this object and specifiy a blocksize. The nms510 (the remote) unit will go into Dataloop and the master (the sc5520) unit will go into Selftest. The blocksize indicates the number of blocks the Selftest pattern generator will run. There are 1000 bits/block. Emuns 3 through 10 are write only. The only valid responses to a READ are dataloopOn(2) or dataloopOff(1). This test will terminate after the specified number of blocks have been run. Reading test results via the nms510DiagBitErrors or nms510DiagBlockErrors objects while the test is running will cause the test to terminate prematurely and render the results invalid. Test results should be read only after the test is completed and are available from the master (sc5520) unit. The current Test Status can be obtained by reading the sc5520DiagTestStatus object on the master unit, reading test status on the remote unit may interfere with the diagonostic test pattern and cause errors. This test can also be terminated by seting the nms510DiagTestReset object. " ::= { nms510DiagExcEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.8.6.7.1.1 | nms510DiagExcIndex | 0 | 0 | The index value which uniquely identifies the NMS510 to which this entry is applicable. This has the form of a SCinstance which … |
1.3.6.1.4.1.498.8.6.7.1.2 | nms510DiagIntLineloop | 0 | 0 | Lineloop (or Analoop) can be either a Bilaterial or Unilaterial loopback depending on option ddsDteTermaloop. To initiate a Line… |
1.3.6.1.4.1.498.8.6.7.1.4 | nms510DiagEndToEndSelftest | 0 | 0 | To initiate an End to End Selftest(Error Rate Test) SET this object and specifiy a blocksize. Both the remote (nms510) amd maste… |
1.3.6.1.4.1.498.8.6.7.1.5 | nms510DiagNetworkDelay | 0 | 0 | To initiate a Network Delay test SET this object and specifiy runDelayTest. Both the remote (nms510) and master (sc5520) units w… |
1.3.6.1.4.1.498.8.6.7.1.6 | nms510DiagTestStatus | 0 | 0 | This object gives the current diagonostic test status. noTest indicates that no diagonostic test is currently active. Reading thi… |
1.3.6.1.4.1.498.8.6.7.1.7 | nms510DiagExtDataloop | 0 | 0 | To initiate a Dataloop test with no Selftest SET this object and specifiy external, this will allow the data from the DTE attach… |