Reference record for OID 1.3.6.1.4.1.562.36.2.1.134.11.1.2



parent
1.3.6.1.4.1.562.36.2.1.134.11.1 (mscApsProvEntry)
node code
2
node name
mscApsWorkingLine
dot oid
1.3.6.1.4.1.562.36.2.1.134.11.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAps(134) mscApsProvTable(11) mscApsProvEntry(1) mscApsWorkingLine(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAps(134) mscApsProvTable(11) mscApsProvEntry(1) mscApsWorkingLine(2)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAps(134) mscApsProvTable(11) mscApsProvEntry(1) mscApsWorkingLine(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAps(134) mscApsProvTable(11) mscApsProvEntry(1) mscApsWorkingLine(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAps(134) mscApsProvTable(11) mscApsProvEntry(1) mscApsWorkingLine(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAps(134) mscApsProvTable(11) mscApsProvEntry(1) mscApsWorkingLine(2)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAps(134) mscApsProvTable(11) mscApsProvEntry(1) mscApsWorkingLine(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nt(562) msCarrier(36) mscPassport(2) mscComponents(1) mscAps(134) mscApsProvTable(11) mscApsProvEntry(1) mscApsWorkingLine(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/nortel/msCarrier/mscPassport/mscComponents/mscAps/mscApsProvTable/mscApsProvEntry/mscApsWorkingLine
  • /iso/identified-organization/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscAps/mscApsProvTable/mscApsProvEntry/mscApsWorkingLine
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/northernTelecom/msCarrier/mscPassport/mscComponents/mscAps/mscApsProvTable/mscApsProvEntry/mscApsWorkingLine
  • /iso/org/dod/internet/private/enterprise/nt/msCarrier/mscPassport/mscComponents/mscAps/mscApsProvTable/mscApsProvEntry/mscApsWorkingLine
  • /iso/org/dod/internet/private/enterprises/nortel/msCarrier/mscPassport/mscComponents/mscAps/mscApsProvTable/mscApsProvEntry/mscApsWorkingLine
  • /iso/org/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscAps/mscApsProvTable/mscApsProvEntry/mscApsWorkingLine
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/northernTelecom/msCarrier/mscPassport/mscComponents/mscAps/mscApsProvTable/mscApsProvEntry/mscApsWorkingLine
  • /iso/iso-identified-organization/dod/internet/private/enterprises/nt/msCarrier/mscPassport/mscComponents/mscAps/mscApsProvTable/mscApsProvEntry/mscApsWorkingLine
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/562/36/2/1/134/11/1/2

    Description by mibdepot

    This attribute is a link to the Path component whose parent Sonet or
    Sdh component provides the Aps' working line. A value must be
    defined for this component.

    The working line must exist under the same Lp as the protection
    line and must link to a Path component under the same type of port
    component (Sonet or Sdh) as the protection line.

    Valid workingLine and protectionLine pairs must exist. For the
    1pOC12SmLrAtm card, the workingLine must be lp/n sonet/0 path/
    0. For other APS compatible cards, the workingLine and
    protectionLine pairs must use port 0 with port 1 and port 2 with port
    3. For example, if the workingLine is linked to a path on port 0, then
    the protectionLine must be linked to a path on port 1.

    Sonet APS is available on cards of type 2pOC3SmAtm2,
    2pOC3MmAtm2, 4pOC3SmIrAtm, 4pOC3MmAtm, and
    1pOC12SmLrAtm.

    Parsed from file nortelPC-apsV1.mib.txt
    Company: None
    Module: Nortel-MsCarrier-MscPassport-ApsMIB

    Description by circitor

    This attribute is a link to the Path component whose parent Sonet or
    Sdh component provides the Aps' working line. A value must be
    defined for this component.

    The working line must exist under the same Lp as the protection
    line and must link to a Path component under the same type of port
    component (Sonet or Sdh) as the protection line.

    Valid workingLine and protectionLine pairs must exist. For the
    1pOC12SmLrAtm card, the workingLine must be lp/n sonet/0 path/
    0. For other APS compatible cards, the workingLine and
    protectionLine pairs must use port 0 with port 1 and port 2 with port
    3. For example, if the workingLine is linked to a path on port 0, then
    the protectionLine must be linked to a path on port 1.

    Sonet APS is available on cards of type 2pOC3SmAtm2,
    2pOC3MmAtm2, 4pOC3SmIrAtm, 4pOC3MmAtm, and
    1pOC12SmLrAtm.

    Parsed from file Nortel-MsCarrier-MscPassport-ApsMIB.mib
    Module: Nortel-MsCarrier-MscPassport-ApsMIB

    Information by oid_info

    Vendor: Northern Telecom, Ltd.
    Module: Nortel-MsCarrier-MscPassport-ApsMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    mscApsWorkingLine OBJECT-TYPE SYNTAX Link ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is a link to the Path component whose parent Sonet or Sdh component provides the Aps' working line. A value must be defined for this component. The working line must exist under the same Lp as the protection line and must link to a Path component under the same type of port component (Sonet or Sdh) as the protection line. Valid workingLine and protectionLine pairs must exist. For the 1pOC12SmLrAtm card, the workingLine must be lp/n sonet/0 path/ 0. For other APS compatible cards, the workingLine and protectionLine pairs must use port 0 with port 1 and port 2 with port 3. For example, if the workingLine is linked to a path on port 0, then the protectionLine must be linked to a path on port 1. Sonet APS is available on cards of type 2pOC3SmAtm2, 2pOC3MmAtm2, 4pOC3SmIrAtm, 4pOC3MmAtm, and 1pOC12SmLrAtm." ::= { mscApsProvEntry 2 }

    Information by circitor

    mscApsWorkingLine OBJECT-TYPE SYNTAX Link ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is a link to the Path component whose parent Sonet or Sdh component provides the Aps' working line. A value must be defined for this component. The working line must exist under the same Lp as the protection line and must link to a Path component under the same type of port component (Sonet or Sdh) as the protection line. Valid workingLine and protectionLine pairs must exist. For the 1pOC12SmLrAtm card, the workingLine must be lp/n sonet/0 path/ 0. For other APS compatible cards, the workingLine and protectionLine pairs must use port 0 with port 1 and port 2 with port 3. For example, if the workingLine is linked to a path on port 0, then the protectionLine must be linked to a path on port 1. Sonet APS is available on cards of type 2pOC3SmAtm2, 2pOC3MmAtm2, 4pOC3SmIrAtm, 4pOC3MmAtm, and 1pOC12SmLrAtm." ::= { mscApsProvEntry 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Sharon Chisholm

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Mike Bobbitt

    Brothers (7)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.562.36.2.1.134.11.1.1 mscApsApplicationFramerName 0 0 This attribute is a link to the service component which utilizes the
    protected Sonet or Sdh interface managed by the Aps compone…
    1.3.6.1.4.1.562.36.2.1.134.11.1.3 mscApsProtectionLine 0 0 This attribute is a link to the Path component whose parent Sonet or
    Sdh component provides the Aps' protection line. A value mu…
    1.3.6.1.4.1.562.36.2.1.134.11.1.4 mscApsMode 0 0 This attribute specifies the protection mode to use. It has possible
    values of unidirectional and bidirectional.

    The unidirectio…
    1.3.6.1.4.1.562.36.2.1.134.11.1.5 mscApsRevertive 0 0 This attribute specifies whether revertive switching is to be used. It
    has possible values of no or yes.

    When this attribute is …
    1.3.6.1.4.1.562.36.2.1.134.11.1.6 mscApsHoldOffTime 0 0 mscApsHoldOfftime
    1.3.6.1.4.1.562.36.2.1.134.11.1.7 mscApsWaitToRestorePeriod 0 0 This attribute specifies the time during which the protection line
    will remain the receive active line after the working line re…
    1.3.6.1.4.1.562.36.2.1.134.11.1.8 mscApsSignalDegradeRatio 0 0 This attribute specifies the minimum bit error ratio (BER) for which
    a Signal Degrade failure is declared. Its value is the expo…