This attribute specifies the minimum bit error ratio (BER) for which
a Signal Degrade failure is declared. Its value is the exponent of the
BER, with possible values of -5 through -9 inclusive, which
correspond to a BER range of 10-5 through 10-9.
The switch initiation time for a Signal Degrade varies depending on
the observed BER (not the provisioned signalDegradeRatio), as
described in the following table.
Observed BER Switch Initiation Time
10-3 10 milliseconds
10-4 100 milliseconds
10-5 1 second
10-6 10 seconds
10-7 100 seconds
10-8 16 minutes 40 seconds
10-9 2 hours 46 minutes 40 seconds
The clearing threshold for a Signal Degrade is one-tenth the
signalDegradeRatio; for example, if the provisioned
signalDegradeRatio is -5, the corresponding clearing threshold will
be 10-6. The clearing time varies depending on the clearing
threshold (not the observed BER), and can be determined from the
above table.
Parsed from file nortelPC-apsV1.mib.txt
Company: None
Module: Nortel-MsCarrier-MscPassport-ApsMIB
This attribute specifies the minimum bit error ratio (BER) for which
a Signal Degrade failure is declared. Its value is the exponent of the
BER, with possible values of -5 through -9 inclusive, which
correspond to a BER range of 10-5 through 10-9.
The switch initiation time for a Signal Degrade varies depending on
the observed BER (not the provisioned signalDegradeRatio), as
described in the following table.
Observed BER Switch Initiation Time
10-3 10 milliseconds
10-4 100 milliseconds
10-5 1 second
10-6 10 seconds
10-7 100 seconds
10-8 16 minutes 40 seconds
10-9 2 hours 46 minutes 40 seconds
The clearing threshold for a Signal Degrade is one-tenth the
signalDegradeRatio; for example, if the provisioned
signalDegradeRatio is -5, the corresponding clearing threshold will
be 10-6. The clearing time varies depending on the clearing
threshold (not the observed BER), and can be determined from the
above table.
Parsed from file Nortel-MsCarrier-MscPassport-ApsMIB.mib
Module: Nortel-MsCarrier-MscPassport-ApsMIB
Vendor: Northern Telecom, Ltd.
Module: Nortel-MsCarrier-MscPassport-ApsMIB
[Automatically extracted from oidview.com]
mscApsSignalDegradeRatio OBJECT-TYPE SYNTAX INTEGER (-9..-5) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the minimum bit error ratio (BER) for which a Signal Degrade failure is declared. Its value is the exponent of the BER, with possible values of -5 through -9 inclusive, which correspond to a BER range of 10-5 through 10-9. The switch initiation time for a Signal Degrade varies depending on the observed BER (not the provisioned signalDegradeRatio), as described in the following table. Observed BER Switch Initiation Time 10-3 10 milliseconds 10-4 100 milliseconds 10-5 1 second 10-6 10 seconds 10-7 100 seconds 10-8 16 minutes 40 seconds 10-9 2 hours 46 minutes 40 seconds The clearing threshold for a Signal Degrade is one-tenth the signalDegradeRatio; for example, if the provisioned signalDegradeRatio is -5, the corresponding clearing threshold will be 10-6. The clearing time varies depending on the clearing threshold (not the observed BER), and can be determined from the above table." DEFVAL { -5 } ::= { mscApsProvEntry 8 }
mscApsSignalDegradeRatio OBJECT-TYPE SYNTAX INTEGER (-9..-5) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the minimum bit error ratio (BER) for which a Signal Degrade failure is declared. Its value is the exponent of the BER, with possible values of -5 through -9 inclusive, which correspond to a BER range of 10-5 through 10-9. The switch initiation time for a Signal Degrade varies depending on the observed BER (not the provisioned signalDegradeRatio), as described in the following table. Observed BER Switch Initiation Time 10-3 10 milliseconds 10-4 100 milliseconds 10-5 1 second 10-6 10 seconds 10-7 100 seconds 10-8 16 minutes 40 seconds 10-9 2 hours 46 minutes 40 seconds The clearing threshold for a Signal Degrade is one-tenth the signalDegradeRatio; for example, if the provisioned signalDegradeRatio is -5, the corresponding clearing threshold will be 10-6. The clearing time varies depending on the clearing threshold (not the observed BER), and can be determined from the above table." DEFVAL { -5 } ::= { mscApsProvEntry 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.562.36.2.1.134.11.1.1 | mscApsApplicationFramerName | 0 | 0 | This attribute is a link to the service component which utilizes the protected Sonet or Sdh interface managed by the Aps compone… |
1.3.6.1.4.1.562.36.2.1.134.11.1.2 | mscApsWorkingLine | 0 | 0 | This attribute is a link to the Path component whose parent Sonet or Sdh component provides the Aps' working line. A value must … |
1.3.6.1.4.1.562.36.2.1.134.11.1.3 | mscApsProtectionLine | 0 | 0 | This attribute is a link to the Path component whose parent Sonet or Sdh component provides the Aps' protection line. A value mu… |
1.3.6.1.4.1.562.36.2.1.134.11.1.4 | mscApsMode | 0 | 0 | This attribute specifies the protection mode to use. It has possible values of unidirectional and bidirectional. The unidirectio… |
1.3.6.1.4.1.562.36.2.1.134.11.1.5 | mscApsRevertive | 0 | 0 | This attribute specifies whether revertive switching is to be used. It has possible values of no or yes. When this attribute is … |
1.3.6.1.4.1.562.36.2.1.134.11.1.6 | mscApsHoldOffTime | 0 | 0 | mscApsHoldOfftime |
1.3.6.1.4.1.562.36.2.1.134.11.1.7 | mscApsWaitToRestorePeriod | 0 | 0 | This attribute specifies the time during which the protection line will remain the receive active line after the working line re… |