Reference record for OID 1.3.6.1.4.1.711.2.1.4.4.1.11



parent
1.3.6.1.4.1.711.2.1.4.4.1 (clc1InfoEntry)
node code
11
node name
clc1InfoAdminControlBandwidthSize
dot oid
1.3.6.1.4.1.711.2.1.4.4.1.11
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lightStream(711) lightStreamProducts(2) atmSwitch(1) portTransmission(4) clc1InfoTable(4) clc1InfoEntry(1) clc1InfoAdminControlBandwidthSize(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lightStream(711) lightStreamProducts(2) atmSwitch(1) portTransmission(4) clc1InfoTable(4) clc1InfoEntry(1) clc1InfoAdminControlBandwidthSize(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) lightStream(711) lightStreamProducts(2) atmSwitch(1) portTransmission(4) clc1InfoTable(4) clc1InfoEntry(1) clc1InfoAdminControlBandwidthSize(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) lightStream(711) lightStreamProducts(2) atmSwitch(1) portTransmission(4) clc1InfoTable(4) clc1InfoEntry(1) clc1InfoAdminControlBandwidthSize(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) lightStream(711) lightStreamProducts(2) atmSwitch(1) portTransmission(4) clc1InfoTable(4) clc1InfoEntry(1) clc1InfoAdminControlBandwidthSize(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) lightStream(711) lightStreamProducts(2) atmSwitch(1) portTransmission(4) clc1InfoTable(4) clc1InfoEntry(1) clc1InfoAdminControlBandwidthSize(11)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/lightStream/lightStreamProducts/atmSwitch/portTransmission/clc1InfoTable/clc1InfoEntry/clc1InfoAdminControlBandwidthSize
  • /iso/identified-organization/dod/internet/private/enterprises/lightStream/lightStreamProducts/atmSwitch/portTransmission/clc1InfoTable/clc1InfoEntry/clc1InfoAdminControlBandwidthSize
  • /iso/org/dod/internet/private/enterprise/lightStream/lightStreamProducts/atmSwitch/portTransmission/clc1InfoTable/clc1InfoEntry/clc1InfoAdminControlBandwidthSize
  • /iso/org/dod/internet/private/enterprises/lightStream/lightStreamProducts/atmSwitch/portTransmission/clc1InfoTable/clc1InfoEntry/clc1InfoAdminControlBandwidthSize
  • /iso/iso-identified-organization/dod/internet/private/enterprise/lightStream/lightStreamProducts/atmSwitch/portTransmission/clc1InfoTable/clc1InfoEntry/clc1InfoAdminControlBandwidthSize
  • /iso/iso-identified-organization/dod/internet/private/enterprises/lightStream/lightStreamProducts/atmSwitch/portTransmission/clc1InfoTable/clc1InfoEntry/clc1InfoAdminControlBandwidthSize
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/711/2/1/4/4/1/11

    Description by cisco_v1

    The current administratively desired value of the
    control bandwidth size for this port. Setting the
    trigger variable clc1InfoAdimOperTrigger will cause
    this value to become the operation value.
    This is a scaling factor. This value is multiplied
    by the port bit rate and the result divided by
    1000 to derive the actual bandwidth.

    Description by mibdepot

    The current administratively desired value of the
    control bandwidth size for this port. Setting the
    trigger variable clc1InfoAdimOperTrigger will cause
    this value to become the operation value.
    This is a scaling factor. This value is multiplied
    by the port bit rate and the result divided by
    1000 to derive the actual bandwidth.

    Parsed from file LS2020-R2-MIB.my.txt
    Company: None
    Module: LIGHTSTREAM-MIB

    Description by circitor

    The current administratively desired value of the
    control bandwidth size for this port. Setting the
    trigger variable clc1InfoAdimOperTrigger will cause
    this value to become the operation value.
    This is a scaling factor. This value is multiplied
    by the port bit rate and the result divided by
    1000 to derive the actual bandwidth.

    Parsed from file LIGHTSTREAM-MIB.mib
    Module: LIGHTSTREAM-MIB

    Information by cisco_v1

    clc1InfoAdminControlBandwidthSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current administratively desired value of the control bandwidth size for this port. Setting the trigger variable clc1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by the port bit rate and the result divided by 1000 to derive the actual bandwidth." ::= { clc1InfoEntry 11 }

    Information by oid_info

    Vendor: Cisco Systems
    Module: LIGHTSTREAM-MIB (LS2020-R2-MIB.my)
    Type: TABULAR
    Access: read-write
    Syntax: INTEGER

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    clc1InfoAdminControlBandwidthSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current administratively desired value of the control bandwidth size for this port. Setting the trigger variable clc1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by the port bit rate and the result divided by 1000 to derive the actual bandwidth." ::= { clc1InfoEntry 11 }

    Information by circitor

    clc1InfoAdminControlBandwidthSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The current administratively desired value of the control bandwidth size for this port. Setting the trigger variable clc1InfoAdimOperTrigger will cause this value to become the operation value. This is a scaling factor. This value is multiplied by the port bit rate and the result divided by 1000 to derive the actual bandwidth." ::= { clc1InfoEntry 11 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.711)

    Chiotasso Chris

    Brothers (18)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.711.2.1.4.4.1.1 clc1InfoIfIndex 0 0 This is the ifIndex value of the corresponding
    ifEntry. See comments above.
    1.3.6.1.4.1.711.2.1.4.4.1.4 clc1InfoOperProtocol 0 0 Operational higher level protocol stack to support
    on this port.
    1.3.6.1.4.1.711.2.1.4.4.1.5 clc1InfoAdminProtocol 0 0 Administratively desired higher level protocol stack
    to support on this port.
    1.3.6.1.4.1.711.2.1.4.4.1.6 clc1InfoOperLoopMode 0 0 Operational loop mode for this port:
    none, internal, or external.
    1.3.6.1.4.1.711.2.1.4.4.1.7 clc1InfoAdminLoopMode 0 0 Administrative or desired loop mode for this
    port: none, internal, or external.
    1.3.6.1.4.1.711.2.1.4.4.1.10 clc1InfoOperControlBandwidthSize 0 0 The current operation value of the control bandwidth
    size for this port. This is a scaling factor. This
    value is multiplied by …
    1.3.6.1.4.1.711.2.1.4.4.1.12 clc1InfoOperDataBandwidthSize 0 0 The current operation value of the data bandwidth
    size for this port. This is a scaling factor. This
    value is multiplied by the…
    1.3.6.1.4.1.711.2.1.4.4.1.13 clc1InfoAdminDataBandwidthSize 0 0 The current administratively desired value of the
    data bandwidth size for this port. Setting the
    trigger variable clc1InfoAdimOpe…
    1.3.6.1.4.1.711.2.1.4.4.1.14 clc1InfoLcAutoEnable 0 0 State of the LC auto-enable flag for this port. If
    enabled the port will be enable at LC boot time.
    If disabled the port will re…
    1.3.6.1.4.1.711.2.1.4.4.1.15 clc1InfoLcDebugLevel 0 0 Value of the LC debug level variable for this port.
    This parameter is set in the LC EEPROM by portctl.
    1.3.6.1.4.1.711.2.1.4.4.1.16 clc1InfoOperScramble 0 0 Operational value for Cell Payload scrambling used
    for this port.
    1.3.6.1.4.1.711.2.1.4.4.1.17 clc1InfoAdminScramble 0 0 Administrative value for Cell Payload scrambling used for
    this port. Setting the trigger variable
    clc1InfoAdimOperTrigger will c…
    1.3.6.1.4.1.711.2.1.4.4.1.18 clc1InfoDataCellCapacity 0 0 The portion of this port's capacity in cells that
    is allocated for data traffic.
    1.3.6.1.4.1.711.2.1.4.4.1.19 clc1InfoDataCellAvailable 0 0 The portion of this port's capacity in cells that
    is available for data traffic. This variable
    is adjusted for the bandwidth con…
    1.3.6.1.4.1.711.2.1.4.4.1.20 clc1InfoLinkUtilization 0 0 This is an estimated utilization on the link.
    1.3.6.1.4.1.711.2.1.4.4.1.21 clc1InfoOperClock 0 0 Operational value for the source of transmit clock for this port.
    1.3.6.1.4.1.711.2.1.4.4.1.22 clc1InfoAdminClock 0 0 Administrative value for the source of transmit clock
    used for this port. Setting the trigger variable
    clc1InfoAdimOperTrigger w…
    1.3.6.1.4.1.711.2.1.4.4.1.99 clc1InfoAdminOperTrigger 0 0 When proper commands written to this variable the
    LCC attempts to change the state of the port such
    that the oper status reflects…