The value of this object specifies the behaviour
of the equipment with respect to an incoming
unknown facility. The authorized values are :
noCheck : no checking,
remove : the unknown facility is not sent,
clear : clearing.
The default value is 'noCheck'.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object specifies the behaviour
of the equipment with respect to an incoming
unknown facility. The authorized values are :
noCheck : no checking,
remove : the unknown facility is not sent,
clear : clearing.
The default value is 'noCheck'.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fclX25CfaFacInputUnknownFacility OBJECT-TYPE SYNTAX INTEGER { noCheck(1), clear(3), remove(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object specifies the behaviour of the equipment with respect to an incoming unknown facility. The authorized values are : noCheck : no checking, remove : the unknown facility is not sent, clear : clearing. The default value is 'noCheck'." ::= { fclX25CfaFacilityEntry 11 }
fclX25CfaFacInputUnknownFacility OBJECT-TYPE SYNTAX INTEGER { noCheck(1), clear(3), remove(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object specifies the behaviour of the equipment with respect to an incoming unknown facility. The authorized values are : noCheck : no checking, remove : the unknown facility is not sent, clear : clearing. The default value is 'noCheck'." ::= { fclX25CfaFacilityEntry 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.20.50.1.20.1.1 | fclX25CfaFacConfigId | 0 | 0 | The value of this object identifies one and only one X25 access configuration. The possible values are : '0..199. If it is unused… |
1.3.6.1.4.1.866.20.1.20.50.1.20.1.2 | fclX25CfaFacClosedUserGroup | 0 | 0 | The value of this object specifies the behaviour of the equipment with respect to the Closed User Group (CUG) facility. There are… |
1.3.6.1.4.1.866.20.1.20.50.1.20.1.5 | fclX25CfaFacReverseCharging | 0 | 0 | The value of this object specifies the behaviour of the equipment with respect to the reverse charging facility. If the called su… |
1.3.6.1.4.1.866.20.1.20.50.1.20.1.6 | fclX25CfaFacTransitDelay | 0 | 0 | The value of this object specifies the behaviour of the equipment with respect to the transit delay facility. The authorized valu… |
1.3.6.1.4.1.866.20.1.20.50.1.20.1.7 | fclX25CfaFacOutputMarkers | 0 | 0 | The value of this object specifies the behaviour of the equipment with respect to the outgoing facility markers. The authorized v… |
1.3.6.1.4.1.866.20.1.20.50.1.20.1.8 | fclX25CfaFacInputMarkers | 0 | 0 | Marqueurs en reception |
1.3.6.1.4.1.866.20.1.20.50.1.20.1.10 | fclX25CfaFacOutputUnknownFacility | 0 | 0 | The value of this object specifies the behaviour of the equipment with respect to an outgoing unknown facility. The authorized va… |