Reference record for OID 1.3.6.1.4.1.866.20.1.20.50.1.20.1.7



parent
1.3.6.1.4.1.866.20.1.20.50.1.20.1 (fclX25CfaFacilityEntry)
node code
7
node name
fclX25CfaFacOutputMarkers
dot oid
1.3.6.1.4.1.866.20.1.20.50.1.20.1.7
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacOutputMarkers(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacOutputMarkers(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacOutputMarkers(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacOutputMarkers(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacOutputMarkers(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacOutputMarkers(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacOutputMarkers
  • /iso/identified-organization/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacOutputMarkers
  • /iso/org/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacOutputMarkers
  • /iso/org/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacOutputMarkers
  • /iso/iso-identified-organization/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacOutputMarkers
  • /iso/iso-identified-organization/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacOutputMarkers
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/866/20/1/20/50/1/20/1/7

    Description by mibdepot

    The value of this object specifies the behaviour
    of the equipment with respect to the outgoing
    facility markers. The authorized values are :

    noCheck : no checking,

    remove : the markers are not transmitted,

    check : according to the following table :

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    | packet | facility marker |
    | |~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    | | 0000 (1) | 00FF (2) | 000F (3) |
    |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~|
    | call |no checking |clearing (5)|no checking|
    |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~|
    | call | | | |
    |connected|clearing (4)|no checking |no checking|
    |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~|
    | clear | - | - |no checking|
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    (1) : registration codes,
    non-x25 facilities provided by the
    network in case of intranetwork calls,
    non-x25 facilities provided by the
    network to which the calling DTE is
    connected in case of internetwork
    calls
    (2) : non-x25 facilities provided by the
    network to which the calling DTE is
    connected in case of intranetwork
    calls
    (3) : CCITT-specified DTE facilities
    (4) : diagnostic to local equipment = 03 42,
    diagnostic to remote equipment = 11 42
    (5) : diagnostic to local equipment = 03 42

    The default value is 'noCheck'.

    Parsed from file v42ami1e.mib.txt
    Company: None
    Module: PCE-MIB

    Description by circitor

    The value of this object specifies the behaviour
    of the equipment with respect to the outgoing
    facility markers. The authorized values are :

    noCheck : no checking,

    remove : the markers are not transmitted,

    check : according to the following table :

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    | packet | facility marker |
    | |~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    | | 0000 (1) | 00FF (2) | 000F (3) |
    |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~|
    | call |no checking |clearing (5)|no checking|
    |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~|
    | call | | | |
    |connected|clearing (4)|no checking |no checking|
    |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~|
    | clear | - | - |no checking|
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    (1) : registration codes,
    non-x25 facilities provided by the
    network in case of intranetwork calls,
    non-x25 facilities provided by the
    network to which the calling DTE is
    connected in case of internetwork
    calls
    (2) : non-x25 facilities provided by the
    network to which the calling DTE is
    connected in case of intranetwork
    calls
    (3) : CCITT-specified DTE facilities
    (4) : diagnostic to local equipment = 03 42,
    diagnostic to remote equipment = 11 42
    (5) : diagnostic to local equipment = 03 42

    The default value is 'noCheck'.

    Parsed from file PCE-MIB.mib
    Module: PCE-MIB

    Information by oid_info

    Vendor: Philips Communication d'Entreprise Claude Lubin
    Module: PCE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    fclX25CfaFacOutputMarkers OBJECT-TYPE SYNTAX INTEGER { noCheck(1), check(2), remove(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object specifies the behaviour of the equipment with respect to the outgoing facility markers. The authorized values are : noCheck : no checking, remove : the markers are not transmitted, check : according to the following table : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | packet | facility marker | | |~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | 0000 (1) | 00FF (2) | 000F (3) | |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | call |no checking |clearing (5)|no checking| |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | call | | | | |connected|clearing (4)|no checking |no checking| |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | clear | - | - |no checking| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ (1) : registration codes, non-x25 facilities provided by the network in case of intranetwork calls, non-x25 facilities provided by the network to which the calling DTE is connected in case of internetwork calls (2) : non-x25 facilities provided by the network to which the calling DTE is connected in case of intranetwork calls (3) : CCITT-specified DTE facilities (4) : diagnostic to local equipment = 03 42, diagnostic to remote equipment = 11 42 (5) : diagnostic to local equipment = 03 42 The default value is 'noCheck'." ::= { fclX25CfaFacilityEntry 7 }

    Information by circitor

    fclX25CfaFacOutputMarkers OBJECT-TYPE SYNTAX INTEGER { noCheck(1), check(2), remove(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object specifies the behaviour of the equipment with respect to the outgoing facility markers. The authorized values are : noCheck : no checking, remove : the markers are not transmitted, check : according to the following table : ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | packet | facility marker | | |~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | 0000 (1) | 00FF (2) | 000F (3) | |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | call |no checking |clearing (5)|no checking| |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | call | | | | |connected|clearing (4)|no checking |no checking| |~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~~|~~~~~~~~~~~| | clear | - | - |no checking| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ (1) : registration codes, non-x25 facilities provided by the network in case of intranetwork calls, non-x25 facilities provided by the network to which the calling DTE is connected in case of internetwork calls (2) : non-x25 facilities provided by the network to which the calling DTE is connected in case of intranetwork calls (3) : CCITT-specified DTE facilities (4) : diagnostic to local equipment = 03 42, diagnostic to remote equipment = 11 42 (5) : diagnostic to local equipment = 03 42 The default value is 'noCheck'." ::= { fclX25CfaFacilityEntry 7 }

    Brothers (7)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.1 fclX25CfaFacConfigId 0 0 The value of this object identifies one and only
    one X25 access configuration. The possible values
    are : '0..199. If it is unused…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.2 fclX25CfaFacClosedUserGroup 0 0 The value of this object specifies the behaviour
    of the equipment with respect to the Closed User
    Group (CUG) facility. There are…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.5 fclX25CfaFacReverseCharging 0 0 The value of this object specifies the behaviour
    of the equipment with respect to the reverse
    charging facility. If the called su…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.6 fclX25CfaFacTransitDelay 0 0 The value of this object specifies the behaviour
    of the equipment with respect to the transit delay
    facility. The authorized valu…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.8 fclX25CfaFacInputMarkers 0 0 Marqueurs en reception
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.10 fclX25CfaFacOutputUnknownFacility 0 0 The value of this object specifies the behaviour
    of the equipment with respect to an outgoing
    unknown facility. The authorized va…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.11 fclX25CfaFacInputUnknownFacility 0 0 The value of this object specifies the behaviour
    of the equipment with respect to an incoming
    unknown facility. The authorized va…