Reference record for OID 1.3.6.1.4.1.866.20.1.20.50.1.20.1.5



parent
1.3.6.1.4.1.866.20.1.20.50.1.20.1 (fclX25CfaFacilityEntry)
node code
5
node name
fclX25CfaFacReverseCharging
dot oid
1.3.6.1.4.1.866.20.1.20.50.1.20.1.5
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacReverseCharging(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacReverseCharging(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacReverseCharging(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacReverseCharging(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacReverseCharging(5)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) pce(866) frxSoftware(20) frxConfig(1) fcLogicalPorts(20) fclX25Configurations(50) fclX25ConfigAccess(1) fclX25CfaFacilityTable(20) fclX25CfaFacilityEntry(1) fclX25CfaFacReverseCharging(5)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacReverseCharging
  • /iso/identified-organization/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacReverseCharging
  • /iso/org/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacReverseCharging
  • /iso/org/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacReverseCharging
  • /iso/iso-identified-organization/dod/internet/private/enterprise/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacReverseCharging
  • /iso/iso-identified-organization/dod/internet/private/enterprises/pce/frxSoftware/frxConfig/fcLogicalPorts/fclX25Configurations/fclX25ConfigAccess/fclX25CfaFacilityTable/fclX25CfaFacilityEntry/fclX25CfaFacReverseCharging
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/866/20/1/20/50/1/20/1/5

    Description by mibdepot

    The value of this object specifies the behaviour
    of the equipment with respect to the reverse
    charging facility. If the called subscriber
    doesn't accept the reverse charging, the call is
    not transmitted and a clear is sent. The default
    value is 'refuse'.

    Parsed from file v42ami1e.mib.txt
    Company: None
    Module: PCE-MIB

    Description by circitor

    The value of this object specifies the behaviour
    of the equipment with respect to the reverse
    charging facility. If the called subscriber
    doesn't accept the reverse charging, the call is
    not transmitted and a clear is sent. The default
    value is 'refuse'.

    Parsed from file PCE-MIB.mib
    Module: PCE-MIB

    Information by oid_info

    Vendor: Philips Communication d'Entreprise Claude Lubin
    Module: PCE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    fclX25CfaFacReverseCharging OBJECT-TYPE SYNTAX INTEGER { refuse(1), accept(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object specifies the behaviour of the equipment with respect to the reverse charging facility. If the called subscriber doesn't accept the reverse charging, the call is not transmitted and a clear is sent. The default value is 'refuse'." ::= { fclX25CfaFacilityEntry 5 }

    Information by circitor

    fclX25CfaFacReverseCharging OBJECT-TYPE SYNTAX INTEGER { refuse(1), accept(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object specifies the behaviour of the equipment with respect to the reverse charging facility. If the called subscriber doesn't accept the reverse charging, the call is not transmitted and a clear is sent. The default value is 'refuse'." ::= { fclX25CfaFacilityEntry 5 }

    Brothers (7)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.1 fclX25CfaFacConfigId 0 0 The value of this object identifies one and only
    one X25 access configuration. The possible values
    are : '0..199. If it is unused…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.2 fclX25CfaFacClosedUserGroup 0 0 The value of this object specifies the behaviour
    of the equipment with respect to the Closed User
    Group (CUG) facility. There are…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.6 fclX25CfaFacTransitDelay 0 0 The value of this object specifies the behaviour
    of the equipment with respect to the transit delay
    facility. The authorized valu…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.7 fclX25CfaFacOutputMarkers 0 0 The value of this object specifies the behaviour
    of the equipment with respect to the outgoing
    facility markers. The authorized v…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.8 fclX25CfaFacInputMarkers 0 0 Marqueurs en reception
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.10 fclX25CfaFacOutputUnknownFacility 0 0 The value of this object specifies the behaviour
    of the equipment with respect to an outgoing
    unknown facility. The authorized va…
    1.3.6.1.4.1.866.20.1.20.50.1.20.1.11 fclX25CfaFacInputUnknownFacility 0 0 The value of this object specifies the behaviour
    of the equipment with respect to an incoming
    unknown facility. The authorized va…