The value of this object defines the maximum
number of simultaneously reliable virtual circuits
in the equipment. The reliable virtual circuits
may be enabled at the logical port level. The
authorized values are '0..255. The default value
is '20'.
Parsed from file v42ami1e.mib.txt
Company: None
Module: PCE-MIB
The value of this object defines the maximum
number of simultaneously reliable virtual circuits
in the equipment. The reliable virtual circuits
may be enabled at the logical port level. The
authorized values are '0..255. The default value
is '20'.
Parsed from file PCE-MIB.mib
Module: PCE-MIB
Vendor: Philips Communication d'Entreprise Claude Lubin
Module: PCE-MIB
[Automatically extracted from oidview.com]
fcwSRvcReliableVcCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object defines the maximum number of simultaneously reliable virtual circuits in the equipment. The reliable virtual circuits may be enabled at the logical port level. The authorized values are '0..255. The default value is '20'." ::= { fcwSerReliableVirtualCircuits 1 }
fcwSRvcReliableVcCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The value of this object defines the maximum number of simultaneously reliable virtual circuits in the equipment. The reliable virtual circuits may be enabled at the logical port level. The authorized values are '0..255. The default value is '20'." ::= { fcwSerReliableVirtualCircuits 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.25.70.2.1.0 | fcwSRvcReliableVcCount | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.866.20.1.25.70.2.2 | fcwSRvcFirstDataPacketTimer | 1 | 1 | The value of this object is the waiting time between the call connected packet and the first data packet which there is clearing … |
1.3.6.1.4.1.866.20.1.25.70.2.3 | fcwSRvcRestoreOutgoingCallRetryCount | 1 | 1 | The value of this object indicates how many times the equipment will try to send a call packet to restore the virtual circuit wic… |
1.3.6.1.4.1.866.20.1.25.70.2.4 | fcwSRvcRestoreMinimumRecallTimer | 1 | 1 | The value of this object specifies the minimum recall time (in seconds) between two successive calls. The authorized values are '… |
1.3.6.1.4.1.866.20.1.25.70.2.5 | fcwSRvcRestoreIncomingCallTimer | 1 | 1 | The value of this object is the time between a new connection request and the reception of the corresponding call connected packe… |
1.3.6.1.4.1.866.20.1.25.70.2.6 | fcwSRvcRestoreOutgoingCallDelay | 1 | 1 | When it is not possible to restore the network connection, the standard forces to not use the called reference number during the … |
1.3.6.1.4.1.866.20.1.25.70.2.7 | fcwSRvcKWindowSize | 1 | 1 | The value of this object indicates the maximum number (K) of sequentially numbered I frames that the equipment may have outstandi… |
1.3.6.1.4.1.866.20.1.25.70.2.8 | fcwSRvcFastSelectUse | 1 | 1 | The value of this object specifies whether the equipment uses the fast select facility or not. The default value is 'onk'. |
1.3.6.1.4.1.866.20.1.25.70.2.9 | fcwSRvcOutputMarkers | 1 | 1 | The value of this object specifies the behaviour of the equipment with respect to the outgoing facility markers. The authorized v… |
1.3.6.1.4.1.866.20.1.25.70.2.10 | fcwSRvcConversionAimedPoint | 1 | 1 | The value of this object indicates whether the 'aimed point' address conversion is enabled or not. This conversion consists in ma… |
1.3.6.1.4.1.866.20.1.25.70.2.11 | fcwSRvcConversionIncomingCall | 1 | 1 | The value of this object indicates which address field are converted on an incoming call. The authorized values are : off : no add… |
1.3.6.1.4.1.866.20.1.25.70.2.12 | fcwSRvcConversionOutgoingCall | 1 | 1 | The value of this object indicates which address field are converted on an outgoing call. The authorized values are : off : no add… |
1.3.6.1.4.1.866.20.1.25.70.2.13 | fcwSRvcConversionAddressCheck | 1 | 1 | The value of this object indicates the behaviour of the equipment when a requested address conversion can not be made because the… |