Reference record for OID 1.3.6.1.4.1.868.2.4.1.2.2.10.1.11



parent
1.3.6.1.4.1.868.2.4.1.2.2.10.1 (cpsmp110Entry)
node code
11
node name
cpsmp110MasterFanFault
dot oid
1.3.6.1.4.1.868.2.4.1.2.2.10.1.11
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp110Table(10) cpsmp110Entry(1) cpsmp110MasterFanFault(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp110Table(10) cpsmp110Entry(1) cpsmp110MasterFanFault(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp110Table(10) cpsmp110Entry(1) cpsmp110MasterFanFault(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp110Table(10) cpsmp110Entry(1) cpsmp110MasterFanFault(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp110Table(10) cpsmp110Entry(1) cpsmp110MasterFanFault(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp110Table(10) cpsmp110Entry(1) cpsmp110MasterFanFault(11)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp110Table/cpsmp110Entry/cpsmp110MasterFanFault
  • /iso/identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp110Table/cpsmp110Entry/cpsmp110MasterFanFault
  • /iso/org/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp110Table/cpsmp110Entry/cpsmp110MasterFanFault
  • /iso/org/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp110Table/cpsmp110Entry/cpsmp110MasterFanFault
  • /iso/iso-identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp110Table/cpsmp110Entry/cpsmp110MasterFanFault
  • /iso/iso-identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp110Table/cpsmp110Entry/cpsmp110MasterFanFault
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/868/2/4/1/2/2/10/1/11

    Description by circitor

    The master fan fault indicator for this device.
    A value of yes(1) indicates that at least one fan current
    sensor encountered a fault condition since the last
    time the device was queried by the management module.
    The statuses of individual fan current sensors can
    be found in cpsmp110FanStatusTbl. Note that in the
    unusual case that a sensor spikes (i.e. encounters a
    fault, and then quickly returns to normal), it will be
    difficult to determine which sensor faulted. However,
    the fact that any sensor faulted is sufficient cause
    to examine the cabinet further.
    There are no subdevices for this value, so the
    placeholder value 1 is always used for that index.

    Parsed from file MCC16-MIB.mib
    Module: MCC16-MIB

    Information by oid_info

    Vendor: Transition Engineering Inc.
    Module: MCC16-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpsmp110MasterFanFault OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The master fan fault indicator for this device. A value of yes(1) indicates that at least one fan current sensor encountered a fault condition since the last time the device was queried by the management module. The statuses of individual fan current sensors can be found in cpsmp110FanStatusTbl. Note that in the unusual case that a sensor spikes (i.e. encounters a fault, and then quickly returns to normal), it will be difficult to determine which sensor faulted. However, the fact that any sensor faulted is sufficient cause to examine the cabinet further. There are no subdevices for this value, so the placeholder value 1 is always used for that index." ::= { cpsmp110Entry 11 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.868)

    Trivedi Hemant

    Brothers (25)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.1 cpsmp110SubDeviceIndex 0 0 Generally, individual devices in this MIB are
    distinguished by BiaIndex and SlotIndex. This
    device differs from many in that it c…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.2 cpsmp110BiaIndex 0 0 The serial number (BIA) of the cabinet in which the
    device is installed.
    There are no subdevices for this value, so the
    placeholde…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.3 cpsmp110SlotIndex 0 0 The slot in which the device is installed. Power Supplies
    occupy special slots numbered 125 and higher.
    There are no subdevices f…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.4 cpsmp110Groups 0 0 User-defined keywords that group this device together with
    other devices under a user-defined scheme. By placing
    matching keyword…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.5 cpsmp110MRevision 0 0 The marketing revision of this device.
    There are no subdevices for this value, so the
    placeholder value 1 is always used for that…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.6 cpsmp110CfgMatch 0 0 yes(1) indicates that the conditions specified in
    cpsGroupCtrl.0 match the Groups value for this
    device. no(2) means that there i…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.7 cpsmp110SerialNumber 0 0 The serial number of this device.
    There are no subdevices for this value, so the
    placeholder value 1 is always used for that inde…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.8 cpsmp110ConfigMode 0 0 This device may have a jumper or switch that disables
    software management of the device. When ConfigMode is
    hardware(2), SNMP man…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.9 cpsmp110MasterTempFault 0 0 The master temperature fault indicator for this device.
    A value of yes(1) indicates that at least one temperature
    sensor encounte…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.10 cpsmp110MasterCurrentFault 0 0 The master current fault indicator for this device.
    A value of yes(1) indicates that at least one current
    sensor encountered a fa…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.12 cpsmp110FirmwareRevision 0 0 The firmware revision level for this device.
    There are no subdevices for this value, so the
    placeholder value 1 is always used fo…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.13 cpsmp110PSSupplyTbl 0 0 The supply voltage that this unit is designed to accept.
    If AC(1), the supply accepts VAC.
    If DC(2), the supply accepts.
    A single …
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.14 cpsmp110PSRoleTbl 0 0 Some power supplies support a Master/Slave relationship:
    When one power supply is set to master(1) and the
    other is set to slave(…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.15 cpsmp110PSReadyTbl 0 0 The readiness of this power supply module. A value of
    yes(1) indicates the module is ready to supply power
    to the cabinet. A val…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.16 cpsmp110PSInUseTbl 0 0 The use status of this power supply module. A value of
    yes(1) indicates the module is supplying power to the
    cabinet. This variab…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.17 cpsmp110TemperatureTbl 0 0 The temperature, in tenths of degrees centigrade, read
    by this temperature sensor.
    A single CPSMP110 control unit can support mul…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.18 cpsmp110CurrentTbl 0 0 The current, in milliwatts, read by this current sensor.
    A single CPSMP110 control unit can support multiple
    subdevices of this t…
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.19 cpsmp110FanStatusTbl 0 0 The status of a fan. A value of fault(2) indicates
    that the control unit has detected a problem with the
    fan, usually that it is …
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.20 cpsmp110TempFaultTbl 0 0 Each entry in this column corresponds to an entry
    with the same indices in cpsmp110TemperatureTable.
    It indicates whether or not …
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.21 cpsmp110CurrFaultTbl 0 0 Each entry in this column corresponds to an entry
    with the same indices in cpsmp110CurrentTable.
    It indicates whether or not the …
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.22 cpsmp110PSCount 0 0 The maximum number of power supplies supported
    in this configuration.
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.23 cpsmp110TempSensorCount 0 0 The number of temperature sensors supported in this device.
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.24 cpsmp110CurrSensorCount 0 0 The number of current sensors supported in this device.
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.25 cpsmp110FanCount 0 0 The number of fans supported in this device.
    1.3.6.1.4.1.868.2.4.1.2.2.10.1.26 cpsmp110CacheClean 0 0 When the value is clean(1)Device and Management Module
    cache are synchronized, no automatic corrections to
    configuration will occ…