The current, in milliwatts, read by this current sensor.
A single CPSMP110 control unit can support multiple
subdevices of this type.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cpsmp110CurrentTbl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current, in milliwatts, read by this current sensor. A single CPSMP110 control unit can support multiple subdevices of this type." ::= { cpsmp110Entry 18 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.10.1.1 | cpsmp110SubDeviceIndex | 0 | 0 | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it c… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.2 | cpsmp110BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed. There are no subdevices for this value, so the placeholde… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.3 | cpsmp110SlotIndex | 0 | 0 | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. There are no subdevices f… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.4 | cpsmp110Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.5 | cpsmp110MRevision | 0 | 0 | The marketing revision of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.6 | cpsmp110CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.7 | cpsmp110SerialNumber | 0 | 0 | The serial number of this device. There are no subdevices for this value, so the placeholder value 1 is always used for that inde… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.8 | cpsmp110ConfigMode | 0 | 0 | This device may have a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP man… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.9 | cpsmp110MasterTempFault | 0 | 0 | The master temperature fault indicator for this device. A value of yes(1) indicates that at least one temperature sensor encounte… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.10 | cpsmp110MasterCurrentFault | 0 | 0 | The master current fault indicator for this device. A value of yes(1) indicates that at least one current sensor encountered a fa… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.11 | cpsmp110MasterFanFault | 0 | 0 | The master fan fault indicator for this device. A value of yes(1) indicates that at least one fan current sensor encountered a fa… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.12 | cpsmp110FirmwareRevision | 0 | 0 | The firmware revision level for this device. There are no subdevices for this value, so the placeholder value 1 is always used fo… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.13 | cpsmp110PSSupplyTbl | 0 | 0 | The supply voltage that this unit is designed to accept. If AC(1), the supply accepts VAC. If DC(2), the supply accepts. A single … |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.14 | cpsmp110PSRoleTbl | 0 | 0 | Some power supplies support a Master/Slave relationship: When one power supply is set to master(1) and the other is set to slave(… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.15 | cpsmp110PSReadyTbl | 0 | 0 | The readiness of this power supply module. A value of yes(1) indicates the module is ready to supply power to the cabinet. A val… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.16 | cpsmp110PSInUseTbl | 0 | 0 | The use status of this power supply module. A value of yes(1) indicates the module is supplying power to the cabinet. This variab… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.17 | cpsmp110TemperatureTbl | 0 | 0 | The temperature, in tenths of degrees centigrade, read by this temperature sensor. A single CPSMP110 control unit can support mul… |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.19 | cpsmp110FanStatusTbl | 0 | 0 | The status of a fan. A value of fault(2) indicates that the control unit has detected a problem with the fan, usually that it is … |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.20 | cpsmp110TempFaultTbl | 0 | 0 | Each entry in this column corresponds to an entry with the same indices in cpsmp110TemperatureTable. It indicates whether or not … |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.21 | cpsmp110CurrFaultTbl | 0 | 0 | Each entry in this column corresponds to an entry with the same indices in cpsmp110CurrentTable. It indicates whether or not the … |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.22 | cpsmp110PSCount | 0 | 0 | The maximum number of power supplies supported in this configuration. |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.23 | cpsmp110TempSensorCount | 0 | 0 | The number of temperature sensors supported in this device. |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.24 | cpsmp110CurrSensorCount | 0 | 0 | The number of current sensors supported in this device. |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.25 | cpsmp110FanCount | 0 | 0 | The number of fans supported in this device. |
1.3.6.1.4.1.868.2.4.1.2.2.10.1.26 | cpsmp110CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |