ccscf100FiberLoopback OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable loopback on the copper interface." ::= { ccscf100Entry 15 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.13.1.1 | ccscf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.2 | ccscf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.3 | ccscf100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.4 | ccscf100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.5 | ccscf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.6 | ccscf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.7 | ccscf100ConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.8 | ccscf100FiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.9 | ccscf100CopperLink | 0 | 0 | Status of Copper Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.10 | ccscf100AISFiber | 0 | 0 | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an … |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.11 | ccscf100AISCopper | 0 | 0 | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an … |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.12 | ccscf100DS3LineBuildout | 0 | 0 | The characteristics of the copper interface |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.13 | ccscf100E3DS3 | 0 | 0 | This variable indicates whether the current device is the T1 or the E1 version. |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.14 | ccscf100CopperLoopback | 0 | 0 | Enable loopback on the copper interface. |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.16 | ccscf100ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.17 | ccscf100ConnB | 0 | 0 | The style of Copper connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.18 | ccscf100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |