This device has a jumper or switch that disables
software management of the device. When ConfigMode is
hardware(2), SNMP management is disabled, and all
configuration control comes from physical switches or
jumpers on the device.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
ccscf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { ccscf100Entry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.13.1.1 | ccscf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.2 | ccscf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.3 | ccscf100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.4 | ccscf100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.5 | ccscf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.6 | ccscf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.8 | ccscf100FiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.9 | ccscf100CopperLink | 0 | 0 | Status of Copper Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.10 | ccscf100AISFiber | 0 | 0 | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an … |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.11 | ccscf100AISCopper | 0 | 0 | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an … |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.12 | ccscf100DS3LineBuildout | 0 | 0 | The characteristics of the copper interface |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.13 | ccscf100E3DS3 | 0 | 0 | This variable indicates whether the current device is the T1 or the E1 version. |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.14 | ccscf100CopperLoopback | 0 | 0 | Enable loopback on the copper interface. |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.15 | ccscf100FiberLoopback | 0 | 0 | Enable loopback on the copper interface. |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.16 | ccscf100ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.17 | ccscf100ConnB | 0 | 0 | The style of Copper connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.18 | ccscf100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |