When the value is clean(1)Device and Management Module
cache are synchronized, no automatic corrections to
configuration will occur. When the value is dirty(2)
Device and Management Module cache are not synchronized.
The configuration currently displayed by the application
has not been validated by the device. The device may
need to correct the configuration, in which case the
displayed configuration will change.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
ccscf100CacheClean OBJECT-TYPE SYNTAX INTEGER { clean(1), dirty(2) } ACCESS read-only STATUS mandatory DESCRIPTION "When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occur. When the value is dirty(2) Device and Management Module cache are not synchronized. The configuration currently displayed by the application has not been validated by the device. The device may need to correct the configuration, in which case the displayed configuration will change." ::= { ccscf100Entry 18 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.13.1.1 | ccscf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.2 | ccscf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.3 | ccscf100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.4 | ccscf100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.5 | ccscf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.6 | ccscf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.7 | ccscf100ConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.8 | ccscf100FiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.9 | ccscf100CopperLink | 0 | 0 | Status of Copper Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.10 | ccscf100AISFiber | 0 | 0 | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an … |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.11 | ccscf100AISCopper | 0 | 0 | Alarm Indication Signal. When equal to alarm(1), this means that the other end has TAOS enabled and is currently transmitting an … |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.12 | ccscf100DS3LineBuildout | 0 | 0 | The characteristics of the copper interface |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.13 | ccscf100E3DS3 | 0 | 0 | This variable indicates whether the current device is the T1 or the E1 version. |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.14 | ccscf100CopperLoopback | 0 | 0 | Enable loopback on the copper interface. |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.15 | ccscf100FiberLoopback | 0 | 0 | Enable loopback on the copper interface. |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.16 | ccscf100ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.13.1.17 | ccscf100ConnB | 0 | 0 | The style of Copper connector built into this device |