Generally, individual devices in this MIB are
distinguished by BiaIndex and SlotIndex. This
device differs from many in that it contains
multiple subdevices (in this case, switch ports).
The number of subdevices varies with the manufactured
configuration. Subdevices within devices are indexed
by BiaIndex, SlotIndex, and SubDeviceIndex.
When the subdevice column is read from the table,
the value '1' is always returned.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cdftf100SubDeviceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it contains multiple subdevices (in this case, switch ports). The number of subdevices varies with the manufactured configuration. Subdevices within devices are indexed by BiaIndex, SlotIndex, and SubDeviceIndex. When the subdevice column is read from the table, the value '1' is always returned." ::= { cdftf100Entry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.17.1.2 | cdftf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.3 | cdftf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.4 | cdftf100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.5 | cdftf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.6 | cdftf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.7 | cdftf100MRevision | 0 | 0 | The marketing revision of the device |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.8 | cdftf100TPLinkTbl | 0 | 0 | This table contains the link status of each twisted pair port in the CDFTF100. There are multiple subdevices in this table, numb… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.9 | cdftf100FiberLinkTbl | 0 | 0 | This table contains the link status of each fiber port in the CDFTF100. There are multiple subdevices in this table, numbering o… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.10 | cdftf100TPActivityTbl | 0 | 0 | Netowrk traffic indicator for the copper port(s) on this device. There are multiple subdevices in this table, numbering one entr… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.11 | cdftf100FiberActivityTbl | 0 | 0 | Netowrk traffic indicator for the fiber port(s) on this device. There are multiple subdevices in this table, numbering one entry… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.12 | cdftf100ConnectorTbl | 0 | 0 | This table contains the link status of each port of this device. There are multiple subdevices in this table, numbering one entr… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.13 | cdftf100FirmwareRevision | 0 | 0 | The style of connectors built into each port of this device. |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.14 | cdftf100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |