User-defined keywords that group this device together with
other devices under a user-defined scheme. By placing
matching keywords in cpsGroupCtrl.0, the agent can be
instructed to apply configuration changes simultaneously
to all group members rather than to individual devices.
Every Groups string has three automatically defined
implied values:
1) The model family of the device, e.g. 'CDFTF100'
2) The serial number of the cabinet in which the device
is installed, in decimal with no leading zeroes,
e.g. '12345', and
3) same as 2, with the slot in which the device is
installed appended, enclosed in square brackets.
e.g. '12345[9]'
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cdftf100Groups OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keywords in cpsGroupCtrl.0, the agent can be instructed to apply configuration changes simultaneously to all group members rather than to individual devices. Every Groups string has three automatically defined implied values: 1) The model family of the device, e.g. 'CDFTF100' 2) The serial number of the cabinet in which the device is installed, in decimal with no leading zeroes, e.g. '12345', and 3) same as 2, with the slot in which the device is installed appended, enclosed in square brackets. e.g. '12345[9]'" ::= { cdftf100Entry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.17.1.1 | cdftf100SubDeviceIndex | 0 | 0 | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it c… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.2 | cdftf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.3 | cdftf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.5 | cdftf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.6 | cdftf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.7 | cdftf100MRevision | 0 | 0 | The marketing revision of the device |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.8 | cdftf100TPLinkTbl | 0 | 0 | This table contains the link status of each twisted pair port in the CDFTF100. There are multiple subdevices in this table, numb… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.9 | cdftf100FiberLinkTbl | 0 | 0 | This table contains the link status of each fiber port in the CDFTF100. There are multiple subdevices in this table, numbering o… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.10 | cdftf100TPActivityTbl | 0 | 0 | Netowrk traffic indicator for the copper port(s) on this device. There are multiple subdevices in this table, numbering one entr… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.11 | cdftf100FiberActivityTbl | 0 | 0 | Netowrk traffic indicator for the fiber port(s) on this device. There are multiple subdevices in this table, numbering one entry… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.12 | cdftf100ConnectorTbl | 0 | 0 | This table contains the link status of each port of this device. There are multiple subdevices in this table, numbering one entr… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.13 | cdftf100FirmwareRevision | 0 | 0 | The style of connectors built into each port of this device. |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.14 | cdftf100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |