Netowrk traffic indicator for the copper port(s)
on this device. There are multiple subdevices in this
table, numbering one entry per port.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cdftf100TPActivityTbl OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Netowrk traffic indicator for the copper port(s) on this device. There are multiple subdevices in this table, numbering one entry per port." ::= { cdftf100Entry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.17.1.1 | cdftf100SubDeviceIndex | 0 | 0 | Generally, individual devices in this MIB are distinguished by BiaIndex and SlotIndex. This device differs from many in that it c… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.2 | cdftf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.3 | cdftf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.4 | cdftf100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.5 | cdftf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.6 | cdftf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.7 | cdftf100MRevision | 0 | 0 | The marketing revision of the device |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.8 | cdftf100TPLinkTbl | 0 | 0 | This table contains the link status of each twisted pair port in the CDFTF100. There are multiple subdevices in this table, numb… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.9 | cdftf100FiberLinkTbl | 0 | 0 | This table contains the link status of each fiber port in the CDFTF100. There are multiple subdevices in this table, numbering o… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.11 | cdftf100FiberActivityTbl | 0 | 0 | Netowrk traffic indicator for the fiber port(s) on this device. There are multiple subdevices in this table, numbering one entry… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.12 | cdftf100ConnectorTbl | 0 | 0 | This table contains the link status of each port of this device. There are multiple subdevices in this table, numbering one entr… |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.13 | cdftf100FirmwareRevision | 0 | 0 | The style of connectors built into each port of this device. |
1.3.6.1.4.1.868.2.4.1.2.2.17.1.14 | cdftf100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |