When set to autonegotiate(1), converter sends
Fast Link Pulses on its twisted pair port, thereby
participating in autonegotiation of duplex between
the converter's twisted pair port and that of the
connected station. If that station supports Full-
Duplex (FDX) operation, FDX will be used. If not, the
twisted pair will operate in Half-Duplex (HDX) mode.
When set to hdx100Btx(2), the converter instead sends
100Mbps idles (rather than Fast Link Pulses) on its
twisted pair port (i.e. it declines to negotiate), which
forces the twisted pair to operate in HDX mode
regardless of the capabilities of the connected station.
When operating in HDX mode, the twisted pair can support
traffic in only one direction at a time. In FDX mode,
traffic can pass in both directions simultaneously, thus
theoretically doubling network performance.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cfetf100FastLinkPulse OBJECT-TYPE SYNTAX INTEGER { autonegotiate(1), hdx100Btx(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation of duplex between the converter's twisted pair port and that of the connected station. If that station supports Full- Duplex (FDX) operation, FDX will be used. If not, the twisted pair will operate in Half-Duplex (HDX) mode. When set to hdx100Btx(2), the converter instead sends 100Mbps idles (rather than Fast Link Pulses) on its twisted pair port (i.e. it declines to negotiate), which forces the twisted pair to operate in HDX mode regardless of the capabilities of the connected station. When operating in HDX mode, the twisted pair can support traffic in only one direction at a time. In FDX mode, traffic can pass in both directions simultaneously, thus theoretically doubling network performance." ::= { cfetf100Entry 12 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.4.1.1 | cfetf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.2 | cfetf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.3 | cfetf100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.4 | cfetf100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.5 | cfetf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.6 | cfetf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.7 | cfetf100ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.8 | cfetf100ConnB | 0 | 0 | The style of Copper connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.9 | cfetf100TPLink | 0 | 0 | Status of Twisted Pair Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.10 | cfetf100FiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.11 | cfetf100Fault | 0 | 0 | Value is yes(1) when either TPLink or FiberLink has value linkDown(2) |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.13 | cfetf100Enabled | 0 | 0 | When this configuration item is set to no(2), the device passes no network traffic. |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.14 | cfetf100Pause | 0 | 0 | The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is n… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.15 | cfetf100LinkPassThrough | 0 | 0 | Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.16 | cfetf100AutoCross | 0 | 0 | Enable/Disable for automatic copper TX/RX pair correction. When disabled, the port operates in MDI mode. |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.17 | cfetf100TPActivity | 0 | 0 | Network traffic indicator for Copper side of this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.18 | cfetf100FiberActivity | 0 | 0 | Network traffic indicator for Fiber side of this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.19 | cfetf100ConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.20 | cfetf100FarEndFault | 0 | 0 | Far End Fault configuration of this device. This setting can only be changed by the physical jumper setting on the slide in card… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.21 | cfetf100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |