This device has a jumper or switch that disables
software management of the device. When ConfigMode is
hardware(2), SNMP management is disabled, and all
configuration control comes from physical switches or
jumpers on the device.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cfetf100ConfigMode OBJECT-TYPE SYNTAX INTEGER { software(1), hardware(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP management is disabled, and all configuration control comes from physical switches or jumpers on the device." ::= { cfetf100Entry 19 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.4.1.1 | cfetf100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.2 | cfetf100SlotIndex | 0 | 0 | The slot in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.3 | cfetf100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.4 | cfetf100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.5 | cfetf100CfgMatch | 0 | 0 | yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there i… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.6 | cfetf100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.7 | cfetf100ConnA | 0 | 0 | The style of Fiber connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.8 | cfetf100ConnB | 0 | 0 | The style of Copper connector built into this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.9 | cfetf100TPLink | 0 | 0 | Status of Twisted Pair Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.10 | cfetf100FiberLink | 0 | 0 | Status of Fiber Link for this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.11 | cfetf100Fault | 0 | 0 | Value is yes(1) when either TPLink or FiberLink has value linkDown(2) |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.12 | cfetf100FastLinkPulse | 0 | 0 | When set to autonegotiate(1), converter sends Fast Link Pulses on its twisted pair port, thereby participating in autonegotiation… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.13 | cfetf100Enabled | 0 | 0 | When this configuration item is set to no(2), the device passes no network traffic. |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.14 | cfetf100Pause | 0 | 0 | The Pause feature allows Ethernet MACs that support it to send data pacing 'Pause' messages to each other. Support for Pause is n… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.15 | cfetf100LinkPassThrough | 0 | 0 | Enable/Disable for Link Pass Through, a feature that causes loss of link on one side of a media converter to be passed through to… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.16 | cfetf100AutoCross | 0 | 0 | Enable/Disable for automatic copper TX/RX pair correction. When disabled, the port operates in MDI mode. |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.17 | cfetf100TPActivity | 0 | 0 | Network traffic indicator for Copper side of this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.18 | cfetf100FiberActivity | 0 | 0 | Network traffic indicator for Fiber side of this device |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.20 | cfetf100FarEndFault | 0 | 0 | Far End Fault configuration of this device. This setting can only be changed by the physical jumper setting on the slide in card… |
1.3.6.1.4.1.868.2.4.1.2.2.4.1.21 | cfetf100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |