Reference record for OID 1.3.6.1.4.1.868.2.4.1.2.2.5.1



parent
1.3.6.1.4.1.868.2.4.1.2.2.5 (cfmff100Table)
node code
1
node name
cfmff100Entry
dot oid
1.3.6.1.4.1.868.2.4.1.2.2.5.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry
  • /iso/identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry
  • /iso/org/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry
  • /iso/org/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/868/2/4/1/2/2/5/1

    Description by circitor

    Status and configuration entries for a single CFMFF100

    Parsed from file MCC16-MIB.mib
    Module: MCC16-MIB

    Information by oid_info

    Vendor: Transition Engineering Inc.
    Module: MCC16-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cfmff100Entry OBJECT-TYPE SYNTAX Cfmff100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CFMFF100" INDEX { cfmff100BiaIndex, cfmff100SlotIndex } ::= { cfmff100Table 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.868)

    Trivedi Hemant

    Children (14)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.1 cfmff100BiaIndex 0 0 The serial number (BIA) of the cabinet in which the
    device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.2 cfmff100SlotIndex 0 0 The slot in which the device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.3 cfmff100Groups 0 0 User-defined keywords that group this device together with
    other devices under a user-defined scheme. By placing
    matching keyword…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.4 cfmff100MRevision 0 0 The marketing revision of the device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.5 cfmff100CfgMatch 0 0 yes(1) indicates that the conditions specified in
    cpsGroupCtrl.0 match the Groups value for this
    device. no(2) means that there i…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.6 cfmff100ConnA 0 0 The style of SingleMode connector built into this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.7 cfmff100ConnB 0 0 The style of MultiMode connector built into this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.8 cfmff100SerialNumber 0 0 The serial number of this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.9 cfmff100SMSignal 0 0 Status of singlemode signal detect for this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.10 cfmff100MMSignal 0 0 Status of singlemode signal detect for this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.11 cfmff100Enabled 0 0 Ports on this device can be disabled individually.
    When this control is set to yes(1), the entire device
    is enabled. When it is s…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.12 cfmff100PortShutOff 0 0 This variable reflects the status of the DPT/OPP jumper
    on the board. This jumper controls the behavior of the
    converter when a l…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.13 cfmff100ConfigMode 0 0 This device has a jumper or switch that disables
    software management of the device. When ConfigMode is
    hardware(2), SNMP manageme…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.14 cfmff100CacheClean 0 0 When the value is clean(1)Device and Management Module
    cache are synchronized, no automatic corrections to
    configuration will occ…