Reference record for OID 1.3.6.1.4.1.868.2.4.1.2.2.5.1.11



parent
1.3.6.1.4.1.868.2.4.1.2.2.5.1 (cfmff100Entry)
node code
11
node name
cfmff100Enabled
dot oid
1.3.6.1.4.1.868.2.4.1.2.2.5.1.11
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1) cfmff100Enabled(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1) cfmff100Enabled(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1) cfmff100Enabled(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1) cfmff100Enabled(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1) cfmff100Enabled(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cfmff100Table(5) cfmff100Entry(1) cfmff100Enabled(11)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry/cfmff100Enabled
  • /iso/identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry/cfmff100Enabled
  • /iso/org/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry/cfmff100Enabled
  • /iso/org/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry/cfmff100Enabled
  • /iso/iso-identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry/cfmff100Enabled
  • /iso/iso-identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cfmff100Table/cfmff100Entry/cfmff100Enabled
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/868/2/4/1/2/2/5/1/11

    Description by circitor

    Ports on this device can be disabled individually.
    When this control is set to yes(1), the entire device
    is enabled. When it is set to noP1(2), the SingleMode port
    is disabled. noP2(3) disables the MultiMode port only,
    and no(4) disables both. For most purposes, the values
    noP1(2), noP2(3), and no(4) are equivalent.

    Parsed from file MCC16-MIB.mib
    Module: MCC16-MIB

    Information by oid_info

    Vendor: Transition Engineering Inc.
    Module: MCC16-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cfmff100Enabled OBJECT-TYPE SYNTAX INTEGER { yes(1), noP1(2), noP2(3), no(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Ports on this device can be disabled individually. When this control is set to yes(1), the entire device is enabled. When it is set to noP1(2), the SingleMode port is disabled. noP2(3) disables the MultiMode port only, and no(4) disables both. For most purposes, the values noP1(2), noP2(3), and no(4) are equivalent." ::= { cfmff100Entry 11 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.868)

    Trivedi Hemant

    Brothers (13)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.1 cfmff100BiaIndex 0 0 The serial number (BIA) of the cabinet in which the
    device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.2 cfmff100SlotIndex 0 0 The slot in which the device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.3 cfmff100Groups 0 0 User-defined keywords that group this device together with
    other devices under a user-defined scheme. By placing
    matching keyword…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.4 cfmff100MRevision 0 0 The marketing revision of the device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.5 cfmff100CfgMatch 0 0 yes(1) indicates that the conditions specified in
    cpsGroupCtrl.0 match the Groups value for this
    device. no(2) means that there i…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.6 cfmff100ConnA 0 0 The style of SingleMode connector built into this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.7 cfmff100ConnB 0 0 The style of MultiMode connector built into this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.8 cfmff100SerialNumber 0 0 The serial number of this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.9 cfmff100SMSignal 0 0 Status of singlemode signal detect for this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.10 cfmff100MMSignal 0 0 Status of singlemode signal detect for this device
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.12 cfmff100PortShutOff 0 0 This variable reflects the status of the DPT/OPP jumper
    on the board. This jumper controls the behavior of the
    converter when a l…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.13 cfmff100ConfigMode 0 0 This device has a jumper or switch that disables
    software management of the device. When ConfigMode is
    hardware(2), SNMP manageme…
    1.3.6.1.4.1.868.2.4.1.2.2.5.1.14 cfmff100CacheClean 0 0 When the value is clean(1)Device and Management Module
    cache are synchronized, no automatic corrections to
    configuration will occ…