Reference record for OID 1.3.6.1.4.1.868.2.4.1.2.2.6.1



parent
1.3.6.1.4.1.868.2.4.1.2.2.6 (cpsmp100Table)
node code
1
node name
cpsmp100Entry
dot oid
1.3.6.1.4.1.868.2.4.1.2.2.6.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp100Table(6) cpsmp100Entry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp100Table(6) cpsmp100Entry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp100Table(6) cpsmp100Entry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp100Table(6) cpsmp100Entry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp100Table(6) cpsmp100Entry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) transition(868) products(2) chassis(4) card(1) slotCps(2) cpsSlotDetail(2) cpsmp100Table(6) cpsmp100Entry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp100Table/cpsmp100Entry
  • /iso/identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp100Table/cpsmp100Entry
  • /iso/org/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp100Table/cpsmp100Entry
  • /iso/org/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp100Table/cpsmp100Entry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp100Table/cpsmp100Entry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/transition/products/chassis/card/slotCps/cpsSlotDetail/cpsmp100Table/cpsmp100Entry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/868/2/4/1/2/2/6/1

    Description by circitor

    Status and configuration entries for a single CPSMP100

    Parsed from file MCC16-MIB.mib
    Module: MCC16-MIB

    Information by oid_info

    Vendor: Transition Engineering Inc.
    Module: MCC16-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    cpsmp100Entry OBJECT-TYPE SYNTAX Cpsmp100Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Status and configuration entries for a single CPSMP100" INDEX { cpsmp100BiaIndex, cpsmp100SlotIndex } ::= { cpsmp100Table 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.868)

    Trivedi Hemant

    Children (17)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.1 cpsmp100BiaIndex 0 0 The serial number (BIA) of the cabinet in which the
    device is installed
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.2 cpsmp100SlotIndex 0 0 The slot in which the device is installed. Power Supplies
    occupy special slots numbered 125 and higher.
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.3 cpsmp100Groups 0 0 User-defined keywords that group this device together with
    other devices under a user-defined scheme. By placing
    matching keyword…
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.4 cpsmp100MRevision 0 0 The marketing revision of this device
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.5 cpsmp100CfgMatch 0 0 yes(1) indicates that the conditions specified in
    cpsGroupCtrl.0 match the Groups value for this
    device. no(2) means that there i…
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.6 cpsmp100SerialNumber 0 0 The serial number of this device
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.7 cpsmp100Mode 0 0 When one power supply is set to master(1) and the
    other is set to slave(2), the master will supply
    all power to the cabinet, and …
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.8 cpsmp100ConfigMode 0 0 This device has a jumper or switch that disables
    software management of the device. When ConfigMode is
    hardware(2), SNMP manageme…
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.9 cpsmp100RemoteFan 0 0 A Remote Fan is a device that fits in a power supply
    slot but contains no power supply, only a fan.
    These devices are not managea…
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.10 cpsmp100PowerOK 0 0 This variable has the value yes(1) any time this
    supply is capable of supplying at least 11.6 volts
    to the cabinet. Note that a v…
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.11 cpsmp100InUse 0 0 Value is yes(1) when this supply is currently selected
    to supply power to the cabinet.
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.12 cpsmp100ChassisPower 0 0 Power currently supplied to the cabinet, in milliwatts
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.13 cpsmp100ChassisTemp 0 0 The temperature inside the cabinet as detected by
    the power supply, in tenths of degrees centigrade
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.14 cpsmp100RFanFault 0 0 Normally no(2), this value changes to yes(1) when
    an installed Remote fan is drawing excessive current
    or none at all.
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.15 cpsmp100LFanFault 0 0 Normally no(2), this value changes to yes(1) when
    the Local fan is drawing excessive current or none
    at all.
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.16 cpsmp100SupplyType 0 0 The supply voltage that this unit is designed to accept.
    If AC(1), the supply accepts 90-260VAC, 47 to 400Hz.
    If DC48(2), the sup…
    1.3.6.1.4.1.868.2.4.1.2.2.6.1.17 cpsmp100CacheClean 0 0 When the value is clean(1)Device and Management Module
    cache are synchronized, no automatic corrections to
    configuration will occ…