yes(1) indicates that the conditions specified in
cpsGroupCtrl.0 match the Groups value for this
device. no(2) means that there is no match.
notApplicable(3) indicates that cpsGroupCtrl.0 is null
and therefore no comparison was performed.
Parsed from file MCC16-MIB.mib
Module: MCC16-MIB
Vendor: Transition Engineering Inc.
Module: MCC16-MIB
[Automatically extracted from oidview.com]
cpsmp100CfgMatch OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2), notApplicable(3) } ACCESS read-only STATUS mandatory DESCRIPTION "yes(1) indicates that the conditions specified in cpsGroupCtrl.0 match the Groups value for this device. no(2) means that there is no match. notApplicable(3) indicates that cpsGroupCtrl.0 is null and therefore no comparison was performed." ::= { cpsmp100Entry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.868.2.4.1.2.2.6.1.1 | cpsmp100BiaIndex | 0 | 0 | The serial number (BIA) of the cabinet in which the device is installed |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.2 | cpsmp100SlotIndex | 0 | 0 | The slot in which the device is installed. Power Supplies occupy special slots numbered 125 and higher. |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.3 | cpsmp100Groups | 0 | 0 | User-defined keywords that group this device together with other devices under a user-defined scheme. By placing matching keyword… |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.4 | cpsmp100MRevision | 0 | 0 | The marketing revision of this device |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.6 | cpsmp100SerialNumber | 0 | 0 | The serial number of this device |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.7 | cpsmp100Mode | 0 | 0 | When one power supply is set to master(1) and the other is set to slave(2), the master will supply all power to the cabinet, and … |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.8 | cpsmp100ConfigMode | 0 | 0 | This device has a jumper or switch that disables software management of the device. When ConfigMode is hardware(2), SNMP manageme… |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.9 | cpsmp100RemoteFan | 0 | 0 | A Remote Fan is a device that fits in a power supply slot but contains no power supply, only a fan. These devices are not managea… |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.10 | cpsmp100PowerOK | 0 | 0 | This variable has the value yes(1) any time this supply is capable of supplying at least 11.6 volts to the cabinet. Note that a v… |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.11 | cpsmp100InUse | 0 | 0 | Value is yes(1) when this supply is currently selected to supply power to the cabinet. |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.12 | cpsmp100ChassisPower | 0 | 0 | Power currently supplied to the cabinet, in milliwatts |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.13 | cpsmp100ChassisTemp | 0 | 0 | The temperature inside the cabinet as detected by the power supply, in tenths of degrees centigrade |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.14 | cpsmp100RFanFault | 0 | 0 | Normally no(2), this value changes to yes(1) when an installed Remote fan is drawing excessive current or none at all. |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.15 | cpsmp100LFanFault | 0 | 0 | Normally no(2), this value changes to yes(1) when the Local fan is drawing excessive current or none at all. |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.16 | cpsmp100SupplyType | 0 | 0 | The supply voltage that this unit is designed to accept. If AC(1), the supply accepts 90-260VAC, 47 to 400Hz. If DC48(2), the sup… |
1.3.6.1.4.1.868.2.4.1.2.2.6.1.17 | cpsmp100CacheClean | 0 | 0 | When the value is clean(1)Device and Management Module cache are synchronized, no automatic corrections to configuration will occ… |