The string value used to identify the chassis component associated with the remote system.
Status in source: current.
Names: lldpRemChassisId
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"lldpRemChassisId",
"OBJECT-TYPE",
"SYNTAX",
"LldpChassisId",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"The string value used to identify the chassis component associated with the remote system.\"",
"REFERENCE",
"\"IEEE Std 802.1AB-2005 9.5.2.3\"",
"::=",
"{",
"lldpRemEntry",
"5",
"}"
],
"syntax_tree": [
[
"row",
"LldpChassisId"
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The string value used to identify the chassis component associated with the remote system."
],
[
"REFERENCE",
"IEEE Std 802.1AB-2005 9.5.2.3"
],
null,
null,
null
]
}- Preserved mibdepot archive
· Archived source file
Source location: LLDP-MIB::lldpRemChassisId.Source version and references
Archived: 2026-10-19T00:22:08.895522+00:00. SHA-256:
d9406158bd12967d19e133d481c6967e2a600c9c56dcc23f6072f66dd86e3631{'kind': 'OBJECT-TYPE', 'details': {'module': 'LLDP-MIB', 'imports': {'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Counter32', 'NOTIFICATION-TYPE', 'Gauge32', 'TimeTicks'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'lldpRemChassisId OBJECT-TYPE\n\tSYNTAX \tLldpChassisId\n\tMAX-ACCESS read-only\n\tSTATUS \tcurrent\n\tDESCRIPTION\n\t\t"The string value used to identify the chassis component\n\t\tassociated with the remote system."\n\tREFERENCE\n\t\t"IEEE Std 802.1AB-2005 9.5.2.3"\n\t::= { lldpRemEntry 5 }', 'syntax_tree': [['row', 'LldpChassisId'], None, ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'The string value used to identify the chassis component associated with the remote system.'], ['REFERENCE', 'IEEE Std 802.1AB-2005 9.5.2.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - Preserved mibdepot archive
· Archived source file
Source location: LLDP-MIB::lldpRemChassisId.Source version and references
Archived: 2026-10-19T00:22:09.295006+00:00. SHA-256:
61017ab02c29dbf0b60143e0bc7912170e1dcb7760b73d044cc28086b0f53db7{'kind': 'OBJECT-TYPE', 'details': {'module': 'LLDP-MIB', 'imports': {'RMON2-MIB': ['TimeFilter', 'ZeroBasedCounter32'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Counter32', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'lldpRemChassisId OBJECT-TYPE\r\n SYNTAX LldpChassisId\r\n MAX-ACCESS read-only\r\n STATUS current\r\n DESCRIPTION\r\n "The string value used to identify the chassis component\r\n associated with the remote system."\r\n REFERENCE\r\n "IEEE Std 802.1AB-2005 9.5.2.3"\r\n ::= { lldpRemEntry 5 }', 'syntax_tree': [['row', 'LldpChassisId'], None, ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'The string value used to identify the chassis component associated with the remote system.'], ['REFERENCE', 'IEEE Std 802.1AB-2005 9.5.2.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - Juniper official MIBs
· Publisher's source file
Source location: LLDP-MIB::lldpRemChassisId.Source version and references
Published package: Junos OS Evolved 26.2R1; file: ./lldp.txt.
Same file in Junos OS 26.2R1.
Downloaded: 2026-10-19T21:32:54.066404+00:00. SHA-256:
d066675ddaa0899210ccd35ebd9e027e86de61499a979860f350a2937348fc89{'kind': 'OBJECT-TYPE', 'details': {'module': 'LLDP-MIB', 'imports': {'RMON2-MIB': ['TimeFilter', 'ZeroBasedCounter32'], 'SNMPv2-TC': ['TEXTUAL-CONVENTION', 'TimeStamp', 'TruthValue'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Integer32', 'Counter32', 'Gauge32', 'NOTIFICATION-TYPE'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP', 'NOTIFICATION-GROUP'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'IANA-ADDRESS-FAMILY-NUMBERS-MIB': ['AddressFamilyNumbers']}, 'document': {'software': 'Junos OS Evolved', 'original_name': './lldp.txt', 'release_sha256': '4c9e04162e7a1ead98cea5ea8b3ece10d500a259b04ac8a234167e9d78f97626', 'release_version': '26.2R1'}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'lldpRemChassisId OBJECT-TYPE \n\tSYNTAX LldpChassisId \n\tMAX-ACCESS read-only \n\tSTATUS current\n\tDESCRIPTION\n\t\t"The string value used to identify the chassis component\n\t\tassociated with the remote system."\n\tREFERENCE \n\t\t"IEEE Std 802.1AB-2005 9.5.2.3" \n\t::= { lldpRemEntry 5 }', 'syntax_tree': [['row', 'LldpChassisId'], None, ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'The string value used to identify the chassis component associated with the remote system.'], ['REFERENCE', 'IEEE Std 802.1AB-2005 9.5.2.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4-q1'}