Reference record for OID 1.2.840.10036.1.1.1.91


parent
1.2.840.10036.1.1.1 (dot11StationConfigEntry)
node code
91
node name
dot11AssociationSAQueryRetryTimeout
dot oid
1.2.840.10036.1.1.1.91
type
OBJECT-TYPE
asn1 oid
  • {iso(1) member-body(2) us(840) ieee802dot11(10036) dot11smt(1) dot11StationConfigTable(1) dot11StationConfigEntry(1) dot11AssociationSAQueryRetryTimeout(91)}
  • iri oid
  • /iso/member-body/us/ieee802dot11/dot11smt/dot11StationConfigTable/dot11StationConfigEntry/dot11AssociationSAQueryRetryTimeout
  • iri by oid_info
    /ISO/Member-Body/US/10036/1/1/1/91

    Description by mibdepot

    This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the implementation.

    This attribute specifies the number of time units (TUs) that an AP waits between issuing two subsequent MLME-SAQuery.request primitive primitives.

    Parsed from file 802_11mib.txt
    Company: ieee
    Module: IEEE802dot11-MIB

    Information by oid_info

    Vendor: IEEE
    Module: IEEE802dot11-MIB (802_11mib)
    Type: TABULAR
    Access: read-write
    Syntax: Unsigned32
    (
    1..4294967295 )

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    dot11AssociationSAQueryRetryTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of time units (TUs) that an AP waits between issuing two subsequent MLME-SAQuery.request primitive primitives." DEFVAL { 201 } ::= { dot11StationConfigEntry 91}

    First Registration Authority (recovered by parent 1.2.840.10036)

    Vic Hayes

    Current Registration Authority (recovered by parent 1.2.840)

    Joyce Hsu

    Brothers (135)

    To many brothers! Only 100 nearest brothers are shown.

    OIDNameSub childrenSub Nodes TotalDescription
    ...
    1.2.840.10036.1.1.1.41 dot11DLSAllowedInQBSS 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.42 dot11DLSAllowed 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.43 dot11AssociateStation 0 0 This is a status variable.
    It is written by the MAC when a STA associates.

    This attribute indicates the MAC address from the Addr…
    1.2.840.10036.1.1.1.44 dot11AssociateID 0 0 This is a status variable.
    It is written by the MAC when a STA associates.

    This attribute indicates the Association ID from the m…
    1.2.840.10036.1.1.1.45 dot11AssociateFailStation 0 0 This is a status variable.
    It is written by the MAC when a STA fails to associate.

    This attribute indicates the MAC address from …
    1.2.840.10036.1.1.1.46 dot11AssociateFailStatus 0 0 This is a status variable.
    It is written by the MAC when a STA fails to associate.

    This attribute indicates the most recently tra…
    1.2.840.10036.1.1.1.47 dot11ReassociateStation 0 0 This is a status variable.
    It is written by the MAC when a STA reassociates.

    This attribute indicates the MAC address from the Ad…
    1.2.840.10036.1.1.1.48 dot11ReassociateID 0 0 This is a status variable.
    It is written by the MAC when a STA reassociates.

    This attribute indicates the Association ID from the…
    1.2.840.10036.1.1.1.49 dot11ReassociateFailStation 0 0 This is a status variable.
    It is written by the MAC when a STA fails to reassociate.

    This attribute indicates the MAC address fro…
    1.2.840.10036.1.1.1.50 dot11ReassociateFailStatus 0 0 This is a status variable.
    It is written by the MAC when a STA fails to reassociate.

    This attribute indicates the most recently t…
    1.2.840.10036.1.1.1.51 dot11RadioMeasurementImplemented 0 0 This is a capability variable.
    Its value is determined by device capabilities.

    This attribute, when true, indicates that the stat…
    1.2.840.10036.1.1.1.52 dot11RadioMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity when any of the MIB variables listed in 8.4.2.47 is e…
    1.2.840.10036.1.1.1.53 dot11RMMeasurementProbeDelay 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.54 dot11RMMeasurementPilotPeriod 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.55 dot11RMLinkMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.56 dot11RMNeighborReportActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.57 dot11RMParallelMeasurementsActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.58 dot11RMRepeatedMeasurementsActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.59 dot11RMBeaconPassiveMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.60 dot11RMBeaconActiveMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.61 dot11RMBeaconTableMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.62 dot11RMBeaconMeasurementReportingConditionsActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.63 dot11RMFrameMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.64 dot11RMChannelLoadMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.65 dot11RMNoiseHistogramMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.66 dot11RMStatisticsMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.67 dot11RMLCIMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.68 dot11RMLCIAzimuthActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.69 dot11RMTransmitStreamCategoryMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.70 dot11RMTriggeredTransmitStreamCategoryMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.71 dot11RMAPChannelReportActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.72 dot11RMMIBActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.73 dot11RMMaxMeasurementDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.74 dot11RMNonOperatingChannelMaxMeasurementDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.75 dot11RMMeasurementPilotTransmissionInformationActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.76 dot11RMMeasurementPilotActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.77 dot11RMNeighborReportTSFOffsetActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.78 dot11RMRCPIMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.79 dot11RMRSNIMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.80 dot11RMBSSAverageAccessDelayActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.81 dot11RMBSSAvailableAdmissionCapacityActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.82 dot11RMAntennaInformationActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect for the next MLME-START.request p…
    1.2.840.10036.1.1.1.83 dot11FastBSSTransitionImplemented 0 0 This is a capability variable.
    Its value is determined by device capabilities.

    This object indicates if the entity is fast BSS tr…
    1.2.840.10036.1.1.1.84 dot11LCIDSEImplemented 0 0 This is a capability variable.
    Its value is determined by device capabilities.

    This attribute, when true, indicates that the stat…
    1.2.840.10036.1.1.1.85 dot11LCIDSERequired 0 0 This is a control variable.
    It is written by the SME.

    A STA uses the Dependent Station Enablement procedures if this attribute is…
    1.2.840.10036.1.1.1.86 dot11DSERequired 0 0 This is a control variable.
    It is written by the SME.

    This attribute, when true, indicates that the station operation is dependen…
    1.2.840.10036.1.1.1.87 dot11ExtendedChannelSwitchActivated 0 0 This is a control variable.
    It is written by the SME when the device is initialized for operation in a band defined by an Operat…
    1.2.840.10036.1.1.1.88 dot11RSNAProtectedManagementFramesActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.89 dot11RSNAUnprotectedManagementFramesAllowed 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.90 dot11AssociationSAQueryMaximumTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.92 dot11HighThroughputOptionImplemented 0 0 dot11HighthroughputOptionImplemented
    1.2.840.10036.1.1.1.93 dot11RSNAPBACRequired 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.94 dot11PSMPOptionImplemented 0 0 This is a capability variable.
    Its value is determined by device capabilities.

    This attribute, when true, indicates that the stat…
    1.2.840.10036.1.1.1.95 dot11TunneledDirectLinkSetupImplemented 0 0 This attribute, when true, indicates that the STA implementation is capable of supporting Tunneled DirectLink Setup.
    1.2.840.10036.1.1.1.96 dot11TDLSPeerUAPSDBufferSTAActivated 0 0 This attribute, when true, indicates that the STA implementation is capable of supporting TDLS Peer U-APSD.
    1.2.840.10036.1.1.1.97 dot11TDLSPeerPSMActivated 0 0 This attribute, when true, indicates that the STA implementation is capable of supporting TDLS Peer PSM.
    1.2.840.10036.1.1.1.98 dot11TDLSPeerUAPSDIndicationWindow 0 0 This attribute indicates the minimum interval in Beacon Intervals between successive Peer Traffic Indication frames.
    1.2.840.10036.1.1.1.99 dot11TDLSChannelSwitchingActivated 0 0 This attribute, when true, indicates that the STA implementation is capable of supporting TDLS Channel Switching.
    1.2.840.10036.1.1.1.100 dot11TDLSPeerSTAMissingAckRetryLimit 0 0 This attribute indicates the number of times the TDLS STA may retry a frame for which it does not receive an ACK from TDLS peer…
    1.2.840.10036.1.1.1.101 dot11TDLSResponseTimeout 0 0 This attribute indicates the amount of time in units of seconds the STA waits before timing out a TDLS setup request.
    1.2.840.10036.1.1.1.102 dot11OCBActivated 0 0 A STA uses the defined outside the context of a BSS procedures if and only if this attribute is true. The default value of this…
    1.2.840.10036.1.1.1.103 dot11TDLSProbeDelay 0 0 This attribute indicates the amount of time in units of microseconds the STA waits before transmitting on a new channel, in the…
    1.2.840.10036.1.1.1.104 dot11TDLSDiscoveryRequestWindow 0 0 This attribute indicates the minimum number of DTIM intervals between successive TDLS Discovery Request frames.
    1.2.840.10036.1.1.1.105 dot11TDLSACDeterminationInterval 0 0 This attribute indicates the number of seconds during which the lowest AC of transmitted traffic is determined.
    1.2.840.10036.1.1.1.106 dot11WirelessManagementImplemented 0 0 This is a capability variable.
    Its value is determined by device capabilities.

    This attribute, when true, indicates that the sta…
    1.2.840.10036.1.1.1.107 dot11BssMaxIdlePeriod 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.108 dot11BssMaxIdlePeriodOptions 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.109 dot11TIMBroadcastInterval 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.110 dot11TIMBroadcastOffset 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.111 dot11TIMBroadcastHighRateTIMRate 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.112 dot11TIMBroadcastLowRateTIMRate 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.113 dot11StatsMinTriggerTimeout 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.114 dot11RMCivicMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.115 dot11RMIdentifierMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.116 dot11TimeAdvertisementDTIMInterval 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.117 dot11InterworkingServiceImplemented 0 0 This is a capability variable.

    Its value is determined by device capabilities.

    This attribute when true, indicates the STA is c…
    1.2.840.10036.1.1.1.118 dot11InterworkingServiceActivated 0 0 This is a control variable.

    It is written by an external management entity or the SME. Changes take effect as soon as practical…
    1.2.840.10036.1.1.1.119 dot11QosMapImplemented 0 0 This is a capability variable.

    Its value is determined by device capabilities.

    This attribute available at STAs, when true, ind…
    1.2.840.10036.1.1.1.120 dot11QosMapActivated 0 0 This is a control variable.

    It is written by an external management entity or the SME. Changes take effect as soon as practical…
    1.2.840.10036.1.1.1.121 dot11EBRImplemented 0 0 This is a capability variable.

    Its value is determined by device capabilities.

    This attribute available at STAs, when true, ind…
    1.2.840.10036.1.1.1.122 dot11EBRActivated 0 0 This is a control variable.

    It is written by an external management entity or the SME. Changes take effect as soon as practical…
    1.2.840.10036.1.1.1.123 dot11ESNetwork 0 0 This is a control variable.

    It is written by an external management entity or the SME. Changes take effect as soon as practical…
    1.2.840.10036.1.1.1.124 dot11SSPNInterfaceImplemented 0 0 This is a capability variable.

    Its value is determined by device capabilities.

    This attribute when true, indicates the AP is ca…
    1.2.840.10036.1.1.1.125 dot11SSPNInterfaceActivated 0 0 This is a control variable.

    It is written by an external management entity or the SME. Changes take effect as soon as practical…
    1.2.840.10036.1.1.1.126 dot11HESSID 0 0 This is a control variable.

    It is written by an external management entity or the SME. Changes take effect for the next MLME-ST…
    1.2.840.10036.1.1.1.127 dot11EASImplemented 0 0 This is a capability variable.

    Its value is determined by device capabilities.

    This attribute when true, indicates the STA is c…
    1.2.840.10036.1.1.1.128 dot11EASActivated 0 0 This is a control variable.

    It is written by an external management entity or the SME. Changes take effect as soon as practical…
    1.2.840.10036.1.1.1.129 dot11MSGCFImplemented 0 0 This is a capability variable.

    Its value is determined by device capabilities.

    This attribute when true, indicates the non-AP S…
    1.2.840.10036.1.1.1.130 dot11MSGCFActivated 0 0 This is a control variable.

    It is written by an external management entity or the SME. Changes take effect as soon as practical…
    1.2.840.10036.1.1.1.131 dot11TimeAdvertisementTimeError 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.132 dot11TimeAdvertisementTimeValue 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.133 dot11RM3rdPartyMeasurementActivated 0 0 This is a control variable.
    It is written by an external management entity or the SME.
    Changes take effect as soon as practical i…
    1.2.840.10036.1.1.1.134 dot11RejectUnadmittedTraffic 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect at the next MLME-START.request pr…
    1.2.840.10036.1.1.1.135 dot11BSSBroadcastNullCount 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.1.1.1.136 dot11MeshActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    ...