This is a status variable.
It is written by the SME when a management report is completed.
This attribute indicates the duration of each period of interference in microseconds. When the duration of each period of interference is variable the field is set to 2E32-1). When the duration of each period of interference is equal or greater than 2E32-2, the field is set to 2E32-2. If no collocated interference is present the field is set to 0.
Parsed from file 802_11mib.txt
Company: ieee
Module: IEEE802dot11-MIB
Vendor: IEEE
Module: IEEE802dot11-MIB (802_11mib)
Type: TABULAR
Access: read-only
Syntax: Integer32
Automatically extracted from www.mibdepot.com
dot11WNMColocInterfRprtInterfBurstLength OBJECT-TYPE SYNTAX Integer32 UNITS "microseconds" MAX-ACCESS read-only STATUS current DESCRIPTION "This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the duration of each period of interference in microseconds. When the duration of each period of interference is variable the field is set to 2E32-1). When the duration of each period of interference is equal or greater than 2E32-2, the field is set to 2E32-2. If no collocated interference is present the field is set to 0." ::= { dot11WNMColocInterfReportEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.2.840.10036.1.22.2.16.1.1 | dot11WNMColocInterfRprtIndex | 0 | 0 | Index for Collocated Interference Report elements in dot11WNMColocInterfReportTable, greater than 0. |
1.2.840.10036.1.22.2.16.1.2 | dot11WNMColocInterfRprtRqstToken | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the request t… |
1.2.840.10036.1.22.2.16.1.3 | dot11WNMColocInterfRprtIfIndex | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. The ifIndex for this row of WNMColocIn… |
1.2.840.10036.1.22.2.16.1.4 | dot11WNMColocInterfRprtPeriod | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute indicates how often the… |
1.2.840.10036.1.22.2.16.1.5 | dot11WNMColocInterfRprtInterfLevel | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute contains a signed integ… |
1.2.840.10036.1.22.2.16.1.6 | dot11WNMColocInterfRprtInterfAccuracy | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute indicates an unsigned i… |
1.2.840.10036.1.22.2.16.1.7 | dot11WNMColocInterfRprtInterfIndex | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the interfere… |
1.2.840.10036.1.22.2.16.1.8 | dot11WNMColocInterfRprtInterfInterval | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the interval … |
1.2.840.10036.1.22.2.16.1.10 | dot11WNMColocInterfRprtInterfStartTime | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute contains the least sign… |
1.2.840.10036.1.22.2.16.1.11 | dot11WNMColocInterfRprtInterfCenterFreq | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute indicates center freque… |
1.2.840.10036.1.22.2.16.1.12 | dot11WNMColocInterfRprtInterfBandwidth | 0 | 0 | This is a status variable. It is written by the SME when a management report is completed. This attribute indicates the bandwidth… |