Reference record for OID 1.2.840.10036.2.1.1.13


parent
1.2.840.10036.2.1.1 (dot11OperationEntry)
node code
13
node name
dot11HCCAIFSN
dot oid
1.2.840.10036.2.1.1.13
type
OBJECT-TYPE
asn1 oid
  • {iso(1) member-body(2) us(840) ieee802dot11(10036) dot11mac(2) dot11OperationTable(1) dot11OperationEntry(1) dot11HCCAIFSN(13)}
  • iri oid
  • /iso/member-body/us/ieee802dot11/dot11mac/dot11OperationTable/dot11OperationEntry/dot11HCCAIFSN
  • iri by oid_info
    /ISO/Member-Body/US/10036/2/1/1/13

    Description by mibdepot

    This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the implementation.

    This attribute specifies the number of slots, after a SIFS duration, that the HC senses the medium idle either before transmitting or executing a backoff.

    Parsed from file 802_11mib.txt
    Company: ieee
    Module: IEEE802dot11-MIB

    Information by oid_info

    Vendor: IEEE
    Module: IEEE802dot11-MIB (802_11mib)
    Type: TABULAR
    Access: read-write
    Syntax: Unsigned32
    (
    1..15 )

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    dot11HCCAIFSN OBJECT-TYPE SYNTAX Unsigned32 (1..15) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. This attribute specifies the number of slots, after a SIFS duration, that the HC senses the medium idle either before transmitting or executing a backoff." DEFVAL { 1 } ::= { dot11OperationEntry 13 }

    First Registration Authority (recovered by parent 1.2.840.10036)

    Vic Hayes

    Current Registration Authority (recovered by parent 1.2.840)

    Joyce Hsu

    Brothers (40)

    OIDNameSub childrenSub Nodes TotalDescription
    1.2.840.10036.2.1.1.1 dot11MACAddress 0 0 Unique MAC Address assigned to the STA.
    1.2.840.10036.2.1.1.2 dot11RTSThreshold 0 0 This attribute shall indicate the number of octets in an MPDU,
    below which an RTS/CTS handshake shall not be performed. An
    RTS/CT…
    1.2.840.10036.2.1.1.3 dot11ShortRetryLimit 0 0 This attribute shall indicate the maximum number of
    transmission attempts of a frame, the length of which is less
    than or equal t…
    1.2.840.10036.2.1.1.4 dot11LongRetryLimit 0 0 This attribute shall indicate the maximum number of
    transmission attempts of a frame, the length of which is
    greater than dot11RT…
    1.2.840.10036.2.1.1.5 dot11FragmentationThreshold 0 0 This attribute shall specify the current maximum size, in
    octets, of the MPDU that may be delivered to the PHY. An MSDU
    shall be …
    1.2.840.10036.2.1.1.6 dot11MaxTransmitMSDULifetime 0 0 The MaxTransmitMSDULifetime shall be the elapsed time in TU,
    after the initial transmission of an MSDU, after which further
    attem…
    1.2.840.10036.2.1.1.7 dot11MaxReceiveLifetime 0 0 The MaxReceiveLifetime shall be the elapsed time in TU,
    after the initial reception of a fragmented MMPDU or MSDU,
    after which fu…
    1.2.840.10036.2.1.1.8 dot11ManufacturerID 0 0 The ManufacturerID shall include, at a minimum, the name
    of the manufacturer. It may include additional
    information at the manuf…
    1.2.840.10036.2.1.1.9 dot11ProductID 0 0 The ProductID shall include, at a minimum, an identifier
    that is unique to the manufacturer. It may include
    additional informati…
    1.2.840.10036.2.1.1.10 dot11CAPLimit 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.11 dot11HCCWmin 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.12 dot11HCCWmax 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.14 dot11ADDBAResponseTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.15 dot11ADDTSResponseTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.16 dot11ChannelUtilizationBeaconInterval 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.17 dot11ScheduleTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.18 dot11DLSResponseTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.19 dot11QAPMissingAckRetryLimit 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.20 dot11EDCAAveragingPeriod 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.21 dot11HTProtection 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.22 dot11RIFSMode 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.23 dot11PSMPControlledAccess 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.24 dot11ServiceIntervalGranularity 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.25 dot11DualCTSProtection 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.26 dot11LSIGTXOPFullProtectionActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.27 dot11NonGFEntitiesPresent 0 0 This is a status variable.
    It is written by the SME when it determines that the presence of greenfield stations in the BSS has c…
    1.2.840.10036.2.1.1.28 dot11PCOActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.29 dot11PCOFortyMaxDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.30 dot11PCOTwentyMaxDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.31 dot11PCOFortyMinDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.32 dot11PCOTwentyMinDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.33 dot11FortyMHzIntolerant 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.34 dot11BSSWidthTriggerScanInterval 0 0 dot11BSSWidthtriggerScanInterval
    1.2.840.10036.2.1.1.35 dot11BSSWidthChannelTransitionDelayFactor 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.36 dot11OBSSScanPassiveDwell 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.37 dot11OBSSScanActiveDwell 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.38 dot11OBSSScanPassiveTotalPerChannel 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.39 dot11OBSSScanActiveTotalPerChannel 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.40 dot112040BSSCoexistenceManagementSupport 0 0 This is a capability variable.
    Its value is determined by device capabilities.

    This attribute, when true, indicates that the STA …
    1.2.840.10036.2.1.1.41 dot11OBSSScanActivityThreshold 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…