Reference record for OID 1.2.840.10036.2.1.1.6


parent
1.2.840.10036.2.1.1 (dot11OperationEntry)
node code
6
node name
dot11MaxTransmitMSDULifetime
dot oid
1.2.840.10036.2.1.1.6
type
OBJECT-TYPE
asn1 oid
  • {iso(1) member-body(2) us(840) ieee802dot11(10036) dot11mac(2) dot11OperationTable(1) dot11OperationEntry(1) dot11MaxTransmitMSDULifetime(6)}
  • iri oid
  • /iso/member-body/us/ieee802dot11/dot11mac/dot11OperationTable/dot11OperationEntry/dot11MaxTransmitMSDULifetime
  • iri by oid_info
    /ISO/Member-Body/US/10036/2/1/1/6

    Description by circitor

    The MaxTransmitMSDULifetime shall be the elapsed time in TU,
    after the initial transmission of an MSDU, after which further
    attempts to transmit the MSDU shall be terminated. The default
    value of this attribute shall be 512.

    Parsed from file IEEE802dot11-MIB.mib
    Module: IEEE802dot11-MIB

    Description by cisco_v1

    The MaxTransmitMSDULifetime shall be the elapsed time in TU,
    after the initial transmission of an MSDU, after which further
    attempts to transmit the MSDU shall be terminated. The default
    value of this attribute shall be 512.

    Description by oid_info

    dot11MaxTransmitMSDULifetime OBJECT-TYPE
    -- SYNTAX INTEGER (1..4294967295)
    SYNTAX Unsigned32 (1..4294967295)
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
    "The MaxTransmitMSDULifetime shall be the elapsed time in TU,
    after the initial transmission of an MSDU, after which further
    attempts to transmit the MSDU shall be terminated. The default
    value of this attribute shall be 512."

    View at oid-info.com

    Description by mibdepot

    This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the implementation.

    The MaxTransmitMSDULifetime is the elapsed time in TU, after the initial transmission of an MSDU, after which further attempts to transmit the MSDU are terminated.

    Parsed from file 802_11mib.txt
    Company: None
    Module: IEEE802dot11-MIB

    Description by cisco

    The MaxTransmitMSDULifetime shall be the elapsed time in TU,
    after the initial transmission of an MSDU, after which further
    attempts to transmit the MSDU shall be terminated. The default
    value of this attribute shall be 512.

    Information by circitor

    dot11MaxTransmitMSDULifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "The MaxTransmitMSDULifetime shall be the elapsed time in TU, after the initial transmission of an MSDU, after which further attempts to transmit the MSDU shall be terminated. The default value of this attribute shall be 512." ::= { dot11OperationEntry 6 }

    Information by cisco_v1

    dot11MaxTransmitMSDULifetime OBJECT-TYPE SYNTAX Gauge(1..4294967295) ACCESS read-write STATUS mandatory DESCRIPTION "The MaxTransmitMSDULifetime shall be the elapsed time in TU, after the initial transmission of an MSDU, after which further attempts to transmit the MSDU shall be terminated. The default value of this attribute shall be 512." ::= { dot11OperationEntry 6 }

    Information by oid_info

    Automatically extracted from Cisco "SNMP v2 MIBs".

    Information by mibdepot

    dot11MaxTransmitMSDULifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "This is a control variable. It is written by an external management entity. Changes take effect as soon as practical in the implementation. The MaxTransmitMSDULifetime is the elapsed time in TU, after the initial transmission of an MSDU, after which further attempts to transmit the MSDU are terminated." DEFVAL { 512 } ::= { dot11OperationEntry 6 }

    Information by cisco

    dot11MaxTransmitMSDULifetime OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "The MaxTransmitMSDULifetime shall be the elapsed time in TU, after the initial transmission of an MSDU, after which further attempts to transmit the MSDU shall be terminated. The default value of this attribute shall be 512." ::= { dot11OperationEntry 6 }

    First Registration Authority (recovered by parent 1.2.840.10036)

    Vic Hayes

    Current Registration Authority (recovered by parent 1.2.840)

    Joyce Hsu

    Brothers (40)

    OIDNameSub childrenSub Nodes TotalDescription
    1.2.840.10036.2.1.1.1 dot11MACAddress 0 0 Unique MAC Address assigned to the STA.
    1.2.840.10036.2.1.1.2 dot11RTSThreshold 0 0 This attribute shall indicate the number of octets in an MPDU,
    below which an RTS/CTS handshake shall not be performed. An
    RTS/CT…
    1.2.840.10036.2.1.1.3 dot11ShortRetryLimit 0 0 This attribute shall indicate the maximum number of
    transmission attempts of a frame, the length of which is less
    than or equal t…
    1.2.840.10036.2.1.1.4 dot11LongRetryLimit 0 0 This attribute shall indicate the maximum number of
    transmission attempts of a frame, the length of which is
    greater than dot11RT…
    1.2.840.10036.2.1.1.5 dot11FragmentationThreshold 0 0 This attribute shall specify the current maximum size, in
    octets, of the MPDU that may be delivered to the PHY. An MSDU
    shall be …
    1.2.840.10036.2.1.1.7 dot11MaxReceiveLifetime 0 0 The MaxReceiveLifetime shall be the elapsed time in TU,
    after the initial reception of a fragmented MMPDU or MSDU,
    after which fu…
    1.2.840.10036.2.1.1.8 dot11ManufacturerID 0 0 The ManufacturerID shall include, at a minimum, the name
    of the manufacturer. It may include additional
    information at the manuf…
    1.2.840.10036.2.1.1.9 dot11ProductID 0 0 The ProductID shall include, at a minimum, an identifier
    that is unique to the manufacturer. It may include
    additional informati…
    1.2.840.10036.2.1.1.10 dot11CAPLimit 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.11 dot11HCCWmin 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.12 dot11HCCWmax 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.13 dot11HCCAIFSN 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.14 dot11ADDBAResponseTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.15 dot11ADDTSResponseTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.16 dot11ChannelUtilizationBeaconInterval 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.17 dot11ScheduleTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.18 dot11DLSResponseTimeout 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.19 dot11QAPMissingAckRetryLimit 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.20 dot11EDCAAveragingPeriod 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.21 dot11HTProtection 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.22 dot11RIFSMode 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.23 dot11PSMPControlledAccess 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.24 dot11ServiceIntervalGranularity 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.25 dot11DualCTSProtection 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.26 dot11LSIGTXOPFullProtectionActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.27 dot11NonGFEntitiesPresent 0 0 This is a status variable.
    It is written by the SME when it determines that the presence of greenfield stations in the BSS has c…
    1.2.840.10036.2.1.1.28 dot11PCOActivated 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.29 dot11PCOFortyMaxDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.30 dot11PCOTwentyMaxDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.31 dot11PCOFortyMinDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.32 dot11PCOTwentyMinDuration 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.33 dot11FortyMHzIntolerant 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.34 dot11BSSWidthTriggerScanInterval 0 0 dot11BSSWidthtriggerScanInterval
    1.2.840.10036.2.1.1.35 dot11BSSWidthChannelTransitionDelayFactor 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.36 dot11OBSSScanPassiveDwell 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.37 dot11OBSSScanActiveDwell 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.38 dot11OBSSScanPassiveTotalPerChannel 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.39 dot11OBSSScanActiveTotalPerChannel 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…
    1.2.840.10036.2.1.1.40 dot112040BSSCoexistenceManagementSupport 0 0 This is a capability variable.
    Its value is determined by device capabilities.

    This attribute, when true, indicates that the STA …
    1.2.840.10036.2.1.1.41 dot11OBSSScanActivityThreshold 0 0 This is a control variable.
    It is written by an external management entity.
    Changes take effect as soon as practical in the imple…