Reference record for OID 1.3.111.2.802.1.1.31.1.2.1.1

Parent
1.3.111.2.802.1.1.31.1.2.1 (ieee8021PSFPStreamGateTable)
Node code
1
Node name
ieee8021PSFPStreamGateEntry
Numeric OID
1.3.111.2.802.1.1.31.1.2.1.1
URN notation
urn:oid:1.3.111.2.802.1.1.31.1.2.1.1
ASN.1 notation

{1 3 111 2 802 1 1 31 1 2 1 1}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1)}
OID-IRI notation
  • /1/3/111/2/802/1/1/31/1/2/1/1
  • /ISO/Identified-Organization/111/2/802/1/1/31/1/2/1/1
  • /ISO/3/111/2/802/1/1/31/1/2/1/1
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry

Source records

A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.

Status in source: current.

Names: ieee8021PSFPStreamGateEntry

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPStreamGateEntry",
    "OBJECT-TYPE",
    "SYNTAX",
    "Ieee8021PSFPStreamGateEntry",
    "MAX-ACCESS",
    "not-accessible",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.\"",
    "INDEX",
    "{",
    "ieee8021BridgeBaseComponentId",
    ",",
    "ieee8021PSFPStreamGateInstance",
    "}",
    "::=",
    "{",
    "ieee8021PSFPStreamGateTable",
    "1",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "Ieee8021PSFPStreamGateEntry"
    ],
    null,
    [
      "MaxAccessPart",
      "not-accessible"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component."
    ],
    null,
    null,
    [
      "INDEX",
      [
        [
          0,
          "ieee8021BridgeBaseComponentId"
        ],
        [
          0,
          "ieee8021PSFPStreamGateInstance"
        ]
      ]
    ],
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPStreamGateEntry.
    Source version and references

    Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256: c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPStreamGateEntry OBJECT-TYPE\r\n    SYNTAX      Ieee8021PSFPStreamGateEntry \r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "A list of objects that contains the manageable parameters for \r\n        stream gate scheduling for a Bridge component."\r\n    INDEX  { ieee8021BridgeBaseComponentId,\r\n             ieee8021PSFPStreamGateInstance\r\n           }\r\n    ::= { ieee8021PSFPStreamGateTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPStreamGateEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPStreamGateInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPStreamGateEntry.
    Source version and references

    Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256: d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPStreamGateEntry OBJECT-TYPE\r\n    SYNTAX      Ieee8021PSFPStreamGateEntry \r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "A list of objects that contains the manageable parameters for \r\n        stream gate scheduling for a Bridge component."\r\n    INDEX  { ieee8021BridgeBaseComponentId,\r\n             ieee8021PSFPStreamGateInstance\r\n           }\r\n    ::= { ieee8021PSFPStreamGateTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPStreamGateEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPStreamGateInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPStreamGateEntry.
    Source version and references

    Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256: 30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPStreamGateEntry OBJECT-TYPE\n    SYNTAX      Ieee8021PSFPStreamGateEntry \n    MAX-ACCESS  not-accessible\n    STATUS      current\n    DESCRIPTION\n        "A list of objects that contains the manageable parameters for \n        stream gate scheduling for a Bridge component."\n    INDEX  { ieee8021BridgeBaseComponentId,\n             ieee8021PSFPStreamGateInstance\n           }\n    ::= { ieee8021PSFPStreamGateTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPStreamGateEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPStreamGateInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPStreamGateEntry.
    Source version and references

    Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256: 8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPStreamGateEntry OBJECT-TYPE\n    SYNTAX      Ieee8021PSFPStreamGateEntry \n    MAX-ACCESS  not-accessible\n    STATUS      current\n    DESCRIPTION\n        "A list of objects that contains the manageable parameters for \n        stream gate scheduling for a Bridge component."\n    INDEX  { ieee8021BridgeBaseComponentId,\n             ieee8021PSFPStreamGateInstance\n           }\n    ::= { ieee8021PSFPStreamGateTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPStreamGateEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPStreamGateInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPStreamGateEntry.
    Source version and references

    Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256: b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPStreamGateEntry OBJECT-TYPE\r\n    SYNTAX      Ieee8021PSFPStreamGateEntry \r\n    MAX-ACCESS  not-accessible\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "A list of objects that contains the manageable parameters for \r\n        stream gate scheduling for a Bridge component."\r\n    INDEX  { ieee8021BridgeBaseComponentId,\r\n             ieee8021PSFPStreamGateInstance\r\n           }\r\n    ::= { ieee8021PSFPStreamGateTable 1 }', 'syntax_tree': [['row', 'Ieee8021PSFPStreamGateEntry'], None, ['MaxAccessPart', 'not-accessible'], ['Status', 'current'], ['DESCRIPTION', 'A list of objects that contains the manageable parameters for stream gate scheduling for a Bridge component.'], None, None, ['INDEX', [[0, 'ieee8021BridgeBaseComponentId'], [0, 'ieee8021PSFPStreamGateInstance']]], None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Direct children (29)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.31.1.2.1.1.1 ieee8021PSFPStreamGateInstance00
1.3.111.2.802.1.1.31.1.2.1.1.2 ieee8021PSFPGateEnabled00
1.3.111.2.802.1.1.31.1.2.1.1.3 ieee8021PSFPAdminGateStates00
1.3.111.2.802.1.1.31.1.2.1.1.4 ieee8021PSFPOperGateStates00
1.3.111.2.802.1.1.31.1.2.1.1.5 ieee8021PSFPAdminControlListLength00
1.3.111.2.802.1.1.31.1.2.1.1.6 ieee8021PSFPOperControlListLength00
1.3.111.2.802.1.1.31.1.2.1.1.7 ieee8021PSFPAdminControlList00
1.3.111.2.802.1.1.31.1.2.1.1.8 ieee8021PSFPOperControlList00
1.3.111.2.802.1.1.31.1.2.1.1.9 ieee8021PSFPAdminCycleTimeNumerator00
1.3.111.2.802.1.1.31.1.2.1.1.10 ieee8021PSFPAdminCycleTimeDenominator00
1.3.111.2.802.1.1.31.1.2.1.1.11 ieee8021PSFPOperCycleTimeNumerator00
1.3.111.2.802.1.1.31.1.2.1.1.12 ieee8021PSFPOperCycleTimeDenominator00
1.3.111.2.802.1.1.31.1.2.1.1.13 ieee8021PSFPAdminCycleTimeExtension00
1.3.111.2.802.1.1.31.1.2.1.1.14 ieee8021PSFPOperCycleTimeExtension00
1.3.111.2.802.1.1.31.1.2.1.1.15 ieee8021PSFPAdminBaseTime00
1.3.111.2.802.1.1.31.1.2.1.1.16 ieee8021PSFPOperBaseTime00
1.3.111.2.802.1.1.31.1.2.1.1.17 ieee8021PSFPConfigChange00
1.3.111.2.802.1.1.31.1.2.1.1.18 ieee8021PSFPConfigChangeTime00
1.3.111.2.802.1.1.31.1.2.1.1.19 ieee8021PSFPTickGranularity00
1.3.111.2.802.1.1.31.1.2.1.1.20 ieee8021PSFPCurrentTime00
1.3.111.2.802.1.1.31.1.2.1.1.21 ieee8021PSFPConfigPending00
1.3.111.2.802.1.1.31.1.2.1.1.23 ieee8021PSFPConfigChangeError00
1.3.111.2.802.1.1.31.1.2.1.1.24 ieee8021PSFPAdminIPV00
1.3.111.2.802.1.1.31.1.2.1.1.25 ieee8021PSFPOperIPV00
1.3.111.2.802.1.1.31.1.2.1.1.26 ieee8021PSFPGateClosedDueToInvalidRxEnable00
1.3.111.2.802.1.1.31.1.2.1.1.27 ieee8021PSFPGateClosedDueToInvalidRx00
1.3.111.2.802.1.1.31.1.2.1.1.28 ieee8021PSFPGateClosedDueToOctetsExceededEnable00
1.3.111.2.802.1.1.31.1.2.1.1.29 ieee8021PSFPGateClosedDueToOctetsExceeded00
1.3.111.2.802.1.1.31.1.2.1.1.30 ieee8021PSFPStreamGateEntryRowStatus00