Reference record for OID 1.3.111.2.802.1.1.31.1.2.1.1.18

Parent
1.3.111.2.802.1.1.31.1.2.1.1 (ieee8021PSFPStreamGateEntry)
Node code
18
Node name
ieee8021PSFPConfigChangeTime
Numeric OID
1.3.111.2.802.1.1.31.1.2.1.1.18
URN notation
urn:oid:1.3.111.2.802.1.1.31.1.2.1.1.18
ASN.1 notation

{1 3 111 2 802 1 1 31 1 2 1 1 18}

  • {iso(1) identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1) ieee8021PSFPConfigChangeTime(18)}
  • {iso(1) identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1) ieee8021PSFPConfigChangeTime(18)}
  • {iso(1) org(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1) ieee8021PSFPConfigChangeTime(18)}
  • {iso(1) org(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1) ieee8021PSFPConfigChangeTime(18)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1) ieee8021PSFPConfigChangeTime(18)}
  • {iso(1) iso-identified-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1) ieee8021PSFPConfigChangeTime(18)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbered-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1) ieee8021PSFPConfigChangeTime(18)}
  • {iso(1) iso-organization(3) ieee(111) standards-association-numbers-series-standards(2) lan-man-stds(802) ieee802dot1(1) ieee802dot1mibs(1) ieee8021PSFPMib(31) ieee8021PSFPObjects(1) ieee8021PSFPStreamGateParameters(2) ieee8021PSFPStreamGateTable(1) ieee8021PSFPStreamGateEntry(1) ieee8021PSFPConfigChangeTime(18)}
OID-IRI notation
  • /1/3/111/2/802/1/1/31/1/2/1/1/18
  • /ISO/Identified-Organization/111/2/802/1/1/31/1/2/1/1/18
  • /ISO/3/111/2/802/1/1/31/1/2/1/1/18
Named path variants
  • /iso/identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry/ieee8021PSFPConfigChangeTime
  • /iso/identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry/ieee8021PSFPConfigChangeTime
  • /iso/org/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry/ieee8021PSFPConfigChangeTime
  • /iso/org/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry/ieee8021PSFPConfigChangeTime
  • /iso/iso-identified-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry/ieee8021PSFPConfigChangeTime
  • /iso/iso-identified-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry/ieee8021PSFPConfigChangeTime
  • /iso/iso-organization/ieee/standards-association-numbered-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry/ieee8021PSFPConfigChangeTime
  • /iso/iso-organization/ieee/standards-association-numbers-series-standards/lan-man-stds/ieee802dot1/ieee802dot1mibs/ieee8021PSFPMib/ieee8021PSFPObjects/ieee8021PSFPStreamGateParameters/ieee8021PSFPStreamGateTable/ieee8021PSFPStreamGateEntry/ieee8021PSFPConfigChangeTime

Source records

The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.

Status in source: current.

Names: ieee8021PSFPConfigChangeTime

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "ieee8021PSFPConfigChangeTime",
    "OBJECT-TYPE",
    "SYNTAX",
    "IEEE8021STPTPtimeValue",
    "UNITS",
    [
      "literal",
      "225054502074696d6522"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.\"",
    "REFERENCE",
    "\"8.6.8.4, 8.6.9.4, 12.31.3\"",
    "::=",
    "{",
    "ieee8021PSFPStreamGateEntry",
    "18",
    "}"
  ],
  "syntax_tree": [
    [
      "row",
      "IEEE8021STPTPtimeValue"
    ],
    [
      "UNITS",
      "PTP time"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system."
    ],
    [
      "REFERENCE",
      "8.6.8.4, 8.6.9.4, 12.31.3"
    ],
    null,
    null,
    null
  ]
}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPConfigChangeTime.
    Source version and references

    Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256: c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPConfigChangeTime OBJECT-TYPE\r\n    SYNTAX      IEEE8021STPTPtimeValue\r\n    UNITS       "PTP time"\r\n    MAX-ACCESS  read-only\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The PTPtime at which the next config change is scheduled to occur.\r\n        The value is a representation of a PTPtime value, \r\n        consisting of a 48-bit integer\r\n        number of seconds and a 32-bit integer number of nanoseconds.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.31.3"\r\n    ::= { ieee8021PSFPStreamGateEntry 18 }', 'syntax_tree': [['row', 'IEEE8021STPTPtimeValue'], ['UNITS', 'PTP time'], ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.31.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPConfigChangeTime.
    Source version and references

    Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256: d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPConfigChangeTime OBJECT-TYPE\r\n    SYNTAX      IEEE8021STPTPtimeValue\r\n    UNITS       "PTP time"\r\n    MAX-ACCESS  read-only\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The PTPtime at which the next config change is scheduled to occur.\r\n        The value is a representation of a PTPtime value, \r\n        consisting of a 48-bit integer\r\n        number of seconds and a 32-bit integer number of nanoseconds.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.31.3"\r\n    ::= { ieee8021PSFPStreamGateEntry 18 }', 'syntax_tree': [['row', 'IEEE8021STPTPtimeValue'], ['UNITS', 'PTP time'], ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.31.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPConfigChangeTime.
    Source version and references

    Downloaded: 2026-10-19T00:21:45.476326+00:00. SHA-256: 30b09d38410a4a1bd8e44ab65693c620a6e79a4c143d1bef2891258963fc8716

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPConfigChangeTime OBJECT-TYPE\n    SYNTAX      IEEE8021STPTPtimeValue\n    UNITS       "PTP time"\n    MAX-ACCESS  read-only\n    STATUS      current\n    DESCRIPTION\n        "The PTPtime at which the next config change is scheduled to occur.\n        The value is a representation of a PTPtime value, \n        consisting of a 48-bit integer\n        number of seconds and a 32-bit integer number of nanoseconds.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.31.3"\n    ::= { ieee8021PSFPStreamGateEntry 18 }', 'syntax_tree': [['row', 'IEEE8021STPTPtimeValue'], ['UNITS', 'PTP time'], ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.31.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPConfigChangeTime.
    Source version and references

    Downloaded: 2026-10-19T00:21:46.243340+00:00. SHA-256: 8d8083a2649eaa86555161ed570af77db21fc6b8e5d1f4438fcbaab9ae0e6655

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPConfigChangeTime OBJECT-TYPE\n    SYNTAX      IEEE8021STPTPtimeValue\n    UNITS       "PTP time"\n    MAX-ACCESS  read-only\n    STATUS      current\n    DESCRIPTION\n        "The PTPtime at which the next config change is scheduled to occur.\n        The value is a representation of a PTPtime value, \n        consisting of a 48-bit integer\n        number of seconds and a 32-bit integer number of nanoseconds.\n\n        The value of this object MUST be retained across\n        reinitializations of the management system."\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.31.3"\n    ::= { ieee8021PSFPStreamGateEntry 18 }', 'syntax_tree': [['row', 'IEEE8021STPTPtimeValue'], ['UNITS', 'PTP time'], ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.31.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}
  • IEEE 802 · Publisher's source file · Archived source file
    Source location: IEEE8021-PSFP-MIB::ieee8021PSFPConfigChangeTime.
    Source version and references

    Downloaded: 2026-10-19T00:21:47.152458+00:00. SHA-256: b81b1e563359d1c24d0cac37f747949d4ecdc92e10ba44859c96d3f39f9532f0

    {'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPConfigChangeTime OBJECT-TYPE\r\n    SYNTAX      IEEE8021STPTPtimeValue\r\n    UNITS       "PTP time"\r\n    MAX-ACCESS  read-only\r\n    STATUS      current\r\n    DESCRIPTION\r\n        "The PTPtime at which the next config change is scheduled to occur.\r\n        The value is a representation of a PTPtime value, \r\n        consisting of a 48-bit integer\r\n        number of seconds and a 32-bit integer number of nanoseconds.\r\n\r\n        The value of this object MUST be retained across\r\n        reinitializations of the management system."\r\n    REFERENCE   "8.6.8.4, 8.6.9.4, 12.31.3"\r\n    ::= { ieee8021PSFPStreamGateEntry 18 }', 'syntax_tree': [['row', 'IEEE8021STPTPtimeValue'], ['UNITS', 'PTP time'], ['MaxAccessPart', 'read-only'], ['Status', 'current'], ['DESCRIPTION', 'The PTPtime at which the next config change is scheduled to occur. The value is a representation of a PTPtime value, consisting of a 48-bit integer number of seconds and a 32-bit integer number of nanoseconds. The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.8.4, 8.6.9.4, 12.31.3'], None, None, None], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}

Current Registration Authority (inferred from ancestor 1.3)

Frank Farance

Siblings (28)

OIDNameDirect childrenDescendantsDescription
1.3.111.2.802.1.1.31.1.2.1.1.1 ieee8021PSFPStreamGateInstance00
1.3.111.2.802.1.1.31.1.2.1.1.2 ieee8021PSFPGateEnabled00
1.3.111.2.802.1.1.31.1.2.1.1.3 ieee8021PSFPAdminGateStates00
1.3.111.2.802.1.1.31.1.2.1.1.4 ieee8021PSFPOperGateStates00
1.3.111.2.802.1.1.31.1.2.1.1.5 ieee8021PSFPAdminControlListLength00
1.3.111.2.802.1.1.31.1.2.1.1.6 ieee8021PSFPOperControlListLength00
1.3.111.2.802.1.1.31.1.2.1.1.7 ieee8021PSFPAdminControlList00
1.3.111.2.802.1.1.31.1.2.1.1.8 ieee8021PSFPOperControlList00
1.3.111.2.802.1.1.31.1.2.1.1.9 ieee8021PSFPAdminCycleTimeNumerator00
1.3.111.2.802.1.1.31.1.2.1.1.10 ieee8021PSFPAdminCycleTimeDenominator00
1.3.111.2.802.1.1.31.1.2.1.1.11 ieee8021PSFPOperCycleTimeNumerator00
1.3.111.2.802.1.1.31.1.2.1.1.12 ieee8021PSFPOperCycleTimeDenominator00
1.3.111.2.802.1.1.31.1.2.1.1.13 ieee8021PSFPAdminCycleTimeExtension00
1.3.111.2.802.1.1.31.1.2.1.1.14 ieee8021PSFPOperCycleTimeExtension00
1.3.111.2.802.1.1.31.1.2.1.1.15 ieee8021PSFPAdminBaseTime00
1.3.111.2.802.1.1.31.1.2.1.1.16 ieee8021PSFPOperBaseTime00
1.3.111.2.802.1.1.31.1.2.1.1.17 ieee8021PSFPConfigChange00
1.3.111.2.802.1.1.31.1.2.1.1.19 ieee8021PSFPTickGranularity00
1.3.111.2.802.1.1.31.1.2.1.1.20 ieee8021PSFPCurrentTime00
1.3.111.2.802.1.1.31.1.2.1.1.21 ieee8021PSFPConfigPending00
1.3.111.2.802.1.1.31.1.2.1.1.23 ieee8021PSFPConfigChangeError00
1.3.111.2.802.1.1.31.1.2.1.1.24 ieee8021PSFPAdminIPV00
1.3.111.2.802.1.1.31.1.2.1.1.25 ieee8021PSFPOperIPV00
1.3.111.2.802.1.1.31.1.2.1.1.26 ieee8021PSFPGateClosedDueToInvalidRxEnable00
1.3.111.2.802.1.1.31.1.2.1.1.27 ieee8021PSFPGateClosedDueToInvalidRx00
1.3.111.2.802.1.1.31.1.2.1.1.28 ieee8021PSFPGateClosedDueToOctetsExceededEnable00
1.3.111.2.802.1.1.31.1.2.1.1.29 ieee8021PSFPGateClosedDueToOctetsExceeded00
1.3.111.2.802.1.1.31.1.2.1.1.30 ieee8021PSFPStreamGateEntryRowStatus00