The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.
Status in source: current.
Names: ieee8021PSFPGateClosedDueToOctetsExceededEnable
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ieee8021PSFPGateClosedDueToOctetsExceededEnable",
"OBJECT-TYPE",
"SYNTAX",
"TruthValue",
"MAX-ACCESS",
"read-create",
"STATUS",
"current",
"DESCRIPTION",
"\"The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.\"",
"REFERENCE",
"\"8.6.5.1, 8.6.5.1.2, 12.31.3\"",
"DEFVAL",
"{",
"false",
"}",
"::=",
"{",
"ieee8021PSFPStreamGateEntry",
"28",
"}"
],
"syntax_tree": [
[
"row",
"TruthValue"
],
null,
[
"MaxAccessPart",
"read-create"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system."
],
[
"REFERENCE",
"8.6.5.1, 8.6.5.1.2, 12.31.3"
],
null,
null,
[
"DEFVAL",
"false"
]
]
}- IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPGateClosedDueToOctetsExceededEnable.Source version and references
Downloaded: 2026-10-19T00:20:22.458391+00:00. SHA-256:
c07683a01effb8ee3c4c2481bef90b80bb260238fd322e13b8e31863cf0d2570{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPGateClosedDueToOctetsExceededEnable OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-create\r\n STATUS current\r\n DESCRIPTION\r\n "The PSFPGateClosedDueToOctetsExceededEnable object contains\r\n a Boolean value that indicates whether the\r\n PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE)\r\n or disabled (FALSE).\r\n\r\n The value of this object MUST be retained across\r\n reinitializations of the management system."\r\n REFERENCE "8.6.5.1, 8.6.5.1.2, 12.31.3"\r\n DEFVAL { false }\r\n ::= { ieee8021PSFPStreamGateEntry 28}', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 8.6.5.1.2, 12.31.3'], None, None, ['DEFVAL', 'false']], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'} - IEEE 802
· Publisher's source file
· Archived source file
Source location: IEEE8021-PSFP-MIB::ieee8021PSFPGateClosedDueToOctetsExceededEnable.Source version and references
Downloaded: 2026-10-19T00:20:23.281382+00:00. SHA-256:
d470a0966348a5a6228febeb0af4fc673e4bc4b06faf9bf7c2793743567635fe{'kind': 'OBJECT-TYPE', 'details': {'module': 'IEEE8021-PSFP-MIB', 'imports': {'SNMPv2-TC': ['TruthValue', 'RowStatus'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'Unsigned32', 'Integer32', 'Counter64'], 'SNMPv2-CONF': ['MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'IEEE8021-ST-MIB': ['IEEE8021STPTPtimeValue'], 'IEEE8021-TC-MIB': ['ieee802dot1mibs'], 'IEEE8021-BRIDGE-MIB': ['ieee8021BridgeBaseComponentId']}, 'smi_kind': 'OBJECT-TYPE', 'definition': 'ieee8021PSFPGateClosedDueToOctetsExceededEnable OBJECT-TYPE\r\n SYNTAX TruthValue\r\n MAX-ACCESS read-create\r\n STATUS current\r\n DESCRIPTION\r\n "The PSFPGateClosedDueToOctetsExceededEnable object contains\r\n a Boolean value that indicates whether the\r\n PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE)\r\n or disabled (FALSE).\r\n\r\n The value of this object MUST be retained across\r\n reinitializations of the management system."\r\n REFERENCE "8.6.5.1, 8.6.5.1.2, 12.31.3"\r\n DEFVAL { false }\r\n ::= { ieee8021PSFPStreamGateEntry 28}', 'syntax_tree': [['row', 'TruthValue'], None, ['MaxAccessPart', 'read-create'], ['Status', 'current'], ['DESCRIPTION', 'The PSFPGateClosedDueToOctetsExceededEnable object contains a Boolean value that indicates whether the PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE) or disabled (FALSE). The value of this object MUST be retained across reinitializations of the management system.'], ['REFERENCE', '8.6.5.1, 8.6.5.1.2, 12.31.3'], None, None, ['DEFVAL', 'false']], 'source_encoding': 'utf-8-sig'}, 'parser_version': 'mib-4'}