Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"oldPethPsePortCurrentStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"ok",
"(",
"1",
")",
",",
"underCurrent",
"(",
"2",
")",
",",
"overCurrent",
"(",
"3",
")",
",",
"both",
"(",
"4",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Describes a current port status related to the power generation The value ok(1) indicates neither an undercurrent or an overcurrent condition was detected since the attribute was last cleared. The value underCurrent(2) indicates that the port current is below the minimal value since the attribute was last cleared. The value overCurrent(3) indicates that the port current exceeds the maximal value since the attribute was last cleared. The value both(4) indicates that both underCurrent and overCurrent since the attribute was last cleared. This attribute is cleared through the oldPethPsePortCurrentStatusClear action. An undercurrent condition is detected when the current drawn from the PSE at the MDI is less than Off-mode current 2 for a duration greater than Under load time limit. An overcurrent condition is detected when the current drawn from the PSE at the MDI is greater than the overload current limit for a duration greater that Overload time limit. The values Overload current limit, Overload time limit, Off-mode current 2 and Under load time limit are specified in Table 33-5. If a Clause 22 MII or Clause 35 GMII is present, then this will map to the Under Current and Over Current bits specified in 33.6.1.2.2 and 33.6.1.2.3.;\"",
"REFERENCE",
"\"[IEEE DRAFT STANDARD FOR DTE POWER VIA MDI P802.3af/D1.2]\"",
"::=",
"{",
"oldPethPsePortEntry",
"10",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"ok",
1
],
[
"underCurrent",
2
],
[
"overCurrent",
3
],
[
"both",
4
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Describes a current port status related to the power generation The value ok(1) indicates neither an undercurrent or an overcurrent condition was detected since the attribute was last cleared. The value underCurrent(2) indicates that the port current is below the minimal value since the attribute was last cleared. The value overCurrent(3) indicates that the port current exceeds the maximal value since the attribute was last cleared. The value both(4) indicates that both underCurrent and overCurrent since the attribute was last cleared. This attribute is cleared through the oldPethPsePortCurrentStatusClear action. An undercurrent condition is detected when the current drawn from the PSE at the MDI is less than Off-mode current 2 for a duration greater than Under load time limit. An overcurrent condition is detected when the current drawn from the PSE at the MDI is greater than the overload current limit for a duration greater that Overload time limit. The values Overload current limit, Overload time limit, Off-mode current 2 and Under load time limit are specified in Table 33-5. If a Clause 22 MII or Clause 35 GMII is present, then this will map to the Under Current and Over Current bits specified in 33.6.1.2.2 and 33.6.1.2.3.;"
],
[
"REFERENCE",
"[IEEE DRAFT STANDARD FOR DTE POWER VIA MDI P802.3af/D1.2]"
],
null,
null,
null
]
}