"definition": [
"oldPethPsePortDetectionStatus",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"disabled",
"(",
"1",
")",
",",
"searching",
"(",
"2",
")",
",",
"detected",
"(",
"3",
")",
",",
"deliveringPower",
"(",
"4",
")",
",",
"fault",
"(",
"5",
")",
",",
"invalidPD",
"(",
"6",
")",
",",
"test",
"(",
"7",
")",
",",
"denyLowPriority",
"(",
"8",
")",
"}",
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Describes the operational status of the port PD detection. A value of disabled(1) indicates that the PD Detection function has been disabled. A value of searching(2) indicates that the PD Detection function is enabled and is searching for a valid PD. A value of detected(3)indicates that the PD Detection function has detected a valid PD but the PSE is not supplying power. A value of deliveringPower(4) indicates that the port executed the detection algorithm, found a PD connection and is currently delivering power. A value of fault(5) indicates that a fault was detected on the port , faults detected are vendor-specific. A value of invalidPD(6)indicates that the PD Detection function has detected a invalid PD. A value of test(7)indicates that the PD Detection function has been placed in test mode. A value of denyLowPriority(8) indicates that the port was disabled by the power management system, in order to keep active higher priority ports. \"",
"::=",
"{",
"oldPethPsePortEntry",
"7",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"disabled",
1
],
[
"searching",
2
],
[
"detected",
3
],
[
"deliveringPower",
4
],
[
"fault",
5
],
[
"invalidPD",
6
],
[
"test",
7
],
[
"denyLowPriority",
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Describes the operational status of the port PD detection. A value of disabled(1) indicates that the PD Detection function has been disabled. A value of searching(2) indicates that the PD Detection function is enabled and is searching for a valid PD. A value of detected(3)indicates that the PD Detection function has detected a valid PD but the PSE is not supplying power. A value of deliveringPower(4) indicates that the port executed the detection algorithm, found a PD connection and is currently delivering power. A value of fault(5) indicates that a fault was detected on the port , faults detected are vendor-specific. A value of invalidPD(6)indicates that the PD Detection function has detected a invalid PD. A value of test(7)indicates that the PD Detection function has been placed in test mode. A value of denyLowPriority(8) indicates that the port was disabled by the power management system, in order to keep active higher priority ports."
],
null,
null,
null,
null
]
}