mip6CnBUsRejected OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Binding Update requests rejected
by the correspondent node. If a Binding
Acknowledgment message has been sent for the Binding
Update request, the Status code field in the
message will have a value greater than or equal to
128. Otherwise the Binding Update request will be
silently discarded.
Discontinuities in the value of this counter can
occur at re-initialization of the management system,
and at other times as indicated by the value of
mip6CounterDiscontinuityTime.
"
REFERENCE
"RFC 3775 : Section 9.5.1, 9.5.4"
View at oid-info.com
Total number of Binding Update requests rejected
by the correspondent node. If a Binding
Acknowledgment message has been sent for the Binding
Update request, the Status code field in the
message will have a value greater than or equal to
128. Otherwise the Binding Update request will be
silently discarded.
Discontinuities in the value of this counter can
occur at re-initialization of the management system,
and at other times as indicated by the value of
mip6CounterDiscontinuityTime.
Parsed from file rfc4295-Mobile-IPv6.mib.txt
Company: ietf_rfcs
Module: MOBILEIPV6-MIB
Automatically extracted from RFC4295
mip6CnBUsRejected OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of Binding Update requests rejected by the correspondent node. If a Binding Acknowledgment message has been sent for the Binding Update request, the Status code field in the message will have a value greater than or equal to 128. Otherwise the Binding Update request will be silently discarded. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mip6CounterDiscontinuityTime. " REFERENCE "RFC 3775 : Section 9.5.1, 9.5.4" ::= { mip6CnGlobalStats 10 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.133.1.3.2.1.10.0 | mip6CnBUsRejected | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.133.1.3.2.1.1 | mip6CnHomeTestInitsRecd | 1 | 1 | Total number of Home Test Init messages received. Discontinuities in the value of this counter can occur at re-initialization of … |
1.3.6.1.2.1.133.1.3.2.1.2 | mip6CnHomeTestsSent | 1 | 1 | Total number of Home Test messages sent. If a Home Test Init message is found to be valid, a Home Test message will be generated… |
1.3.6.1.2.1.133.1.3.2.1.3 | mip6CnCareOfTestInitsRecd | 1 | 1 | Total number of Care-of Test Init messages received. |
1.3.6.1.2.1.133.1.3.2.1.4 | mip6CnCareOfTestsSent | 1 | 1 | Total number of Care-of Test messages sent. If a Care-of Test Init message is found to be valid, a Care-of Test message will be … |
1.3.6.1.2.1.133.1.3.2.1.5 | mip6CnBUsRecd | 1 | 1 | Total number of Binding Updates received by the correspondent node from mobile nodes. Discontinuities in the value of this counte… |
1.3.6.1.2.1.133.1.3.2.1.6 | mip6CnBUAcksSent | 1 | 1 | Total number of acknowledgments sent by the correspondent node for the Binding Updates received. Discontinuities in the value of … |
1.3.6.1.2.1.133.1.3.2.1.7 | mip6CnBRsSent | 1 | 1 | Total number of Binding Refresh Request messages sent by the correspondent node. Discontinuities in the value of this counter can… |
1.3.6.1.2.1.133.1.3.2.1.8 | mip6CnBindingErrors | 1 | 1 | Total number of Binding Error messages sent by the correspondent node to the mobile node. Discontinuities in the value of this co… |
1.3.6.1.2.1.133.1.3.2.1.9 | mip6CnBUsAccepted | 1 | 1 | Total number of Binding Updates accepted by the correspondent node. If a Binding Acknowledgment message is sent for the Binding … |
1.3.6.1.2.1.133.1.3.2.1.11 | mip6CnReasonUnspecified | 1 | 1 | Total number of Binding Update requests rejected by the correspondent node with status code in the Binding Acknowledgment message… |
1.3.6.1.2.1.133.1.3.2.1.12 | mip6CnInsufficientResource | 1 | 1 | Total number of Binding Update requests rejected by the correspondent node with status code in the Binding Acknowledgment message… |
1.3.6.1.2.1.133.1.3.2.1.13 | mip6CnHomeRegnNotSupported | 1 | 1 | Total number of Binding Update requests rejected by correspondent node with status code in the Binding Acknowledgment message ind… |
1.3.6.1.2.1.133.1.3.2.1.14 | mip6CnSeqNumberOutOfWindow | 1 | 1 | Total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicating … |
1.3.6.1.2.1.133.1.3.2.1.15 | mip6CnExpiredHomeNonceIndex | 1 | 1 | The total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicat… |
1.3.6.1.2.1.133.1.3.2.1.16 | mip6CnExpiredCareOfNonceIndex | 1 | 1 | The total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicat… |
1.3.6.1.2.1.133.1.3.2.1.17 | mip6CnExpiredNonce | 1 | 1 | The total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicat… |
1.3.6.1.2.1.133.1.3.2.1.18 | mip6CnRegTypeChangeDisallowed | 1 | 1 | The total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicat… |