mip6CnSeqNumberOutOfWindow OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of Binding Updates rejected by
correspondent node with status code in the Binding
Acknowledgment message indicating \sequence number
out of window\ (Code 135).
Discontinuities in the value of this counter can
occur at re-initialization of the management system,
and at other times as indicated by the value of
mip6CounterDiscontinuityTime.
"
REFERENCE
"RFC 3775 : Section 6.1.8, 9.5.1"
View at oid-info.com
Total number of Binding Updates rejected by
correspondent node with status code in the Binding
Acknowledgment message indicating 'sequence number
out of window' (Code 135).
Discontinuities in the value of this counter can
occur at re-initialization of the management system,
and at other times as indicated by the value of
mip6CounterDiscontinuityTime.
Parsed from file rfc4295-Mobile-IPv6.mib.txt
Company: ietf_rfcs
Module: MOBILEIPV6-MIB
Automatically extracted from RFC4295
mip6CnSeqNumberOutOfWindow OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicating 'sequence number out of window' (Code 135). Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of mip6CounterDiscontinuityTime. " REFERENCE "RFC 3775 : Section 6.1.8, 9.5.1" ::= { mip6CnGlobalStats 14 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.133.1.3.2.1.14.0 | mip6CnSeqNumberOutOfWindow | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.133.1.3.2.1.1 | mip6CnHomeTestInitsRecd | 1 | 1 | Total number of Home Test Init messages received. Discontinuities in the value of this counter can occur at re-initialization of … |
1.3.6.1.2.1.133.1.3.2.1.2 | mip6CnHomeTestsSent | 1 | 1 | Total number of Home Test messages sent. If a Home Test Init message is found to be valid, a Home Test message will be generated… |
1.3.6.1.2.1.133.1.3.2.1.3 | mip6CnCareOfTestInitsRecd | 1 | 1 | Total number of Care-of Test Init messages received. |
1.3.6.1.2.1.133.1.3.2.1.4 | mip6CnCareOfTestsSent | 1 | 1 | Total number of Care-of Test messages sent. If a Care-of Test Init message is found to be valid, a Care-of Test message will be … |
1.3.6.1.2.1.133.1.3.2.1.5 | mip6CnBUsRecd | 1 | 1 | Total number of Binding Updates received by the correspondent node from mobile nodes. Discontinuities in the value of this counte… |
1.3.6.1.2.1.133.1.3.2.1.6 | mip6CnBUAcksSent | 1 | 1 | Total number of acknowledgments sent by the correspondent node for the Binding Updates received. Discontinuities in the value of … |
1.3.6.1.2.1.133.1.3.2.1.7 | mip6CnBRsSent | 1 | 1 | Total number of Binding Refresh Request messages sent by the correspondent node. Discontinuities in the value of this counter can… |
1.3.6.1.2.1.133.1.3.2.1.8 | mip6CnBindingErrors | 1 | 1 | Total number of Binding Error messages sent by the correspondent node to the mobile node. Discontinuities in the value of this co… |
1.3.6.1.2.1.133.1.3.2.1.9 | mip6CnBUsAccepted | 1 | 1 | Total number of Binding Updates accepted by the correspondent node. If a Binding Acknowledgment message is sent for the Binding … |
1.3.6.1.2.1.133.1.3.2.1.10 | mip6CnBUsRejected | 1 | 1 | Total number of Binding Update requests rejected by the correspondent node. If a Binding Acknowledgment message has been sent fo… |
1.3.6.1.2.1.133.1.3.2.1.11 | mip6CnReasonUnspecified | 1 | 1 | Total number of Binding Update requests rejected by the correspondent node with status code in the Binding Acknowledgment message… |
1.3.6.1.2.1.133.1.3.2.1.12 | mip6CnInsufficientResource | 1 | 1 | Total number of Binding Update requests rejected by the correspondent node with status code in the Binding Acknowledgment message… |
1.3.6.1.2.1.133.1.3.2.1.13 | mip6CnHomeRegnNotSupported | 1 | 1 | Total number of Binding Update requests rejected by correspondent node with status code in the Binding Acknowledgment message ind… |
1.3.6.1.2.1.133.1.3.2.1.15 | mip6CnExpiredHomeNonceIndex | 1 | 1 | The total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicat… |
1.3.6.1.2.1.133.1.3.2.1.16 | mip6CnExpiredCareOfNonceIndex | 1 | 1 | The total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicat… |
1.3.6.1.2.1.133.1.3.2.1.17 | mip6CnExpiredNonce | 1 | 1 | The total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicat… |
1.3.6.1.2.1.133.1.3.2.1.18 | mip6CnRegTypeChangeDisallowed | 1 | 1 | The total number of Binding Updates rejected by correspondent node with status code in the Binding Acknowledgment message indicat… |