dot3OamThresholdEvent NOTIFICATION-TYPE
OBJECTS { dot3OamEventLogTimestamp,
dot3OamEventLogOui,
dot3OamEventLogType,
dot3OamEventLogLocation,
dot3OamEventLogWindowHi,
dot3OamEventLogWindowLo,
dot3OamEventLogThresholdHi,
dot3OamEventLogThresholdLo,
dot3OamEventLogValue,
dot3OamEventLogRunningTotal,
dot3OamEventLogEventTotal
}
STATUS current
DESCRIPTION
"A dot3OamThresholdEvent notification is sent when a local or
remote threshold crossing event is detected. A local
threshold crossing event is detected by the local entity,
while a remote threshold crossing event is detected by the
reception of an Ethernet OAM Event Notification OAMPDU
that indicates a threshold event.
This notification should not be sent more than once per
second.
The OAM entity can be derived from extracting the ifIndex from
the variable bindings. The objects in the notification
correspond to the values in a row instance in the
dot3OamEventLogTable.
The management entity should periodically check
dot3OamEventLogTable to detect any missed events."
View at oid-info.com
A dot3OamThresholdEvent notification is sent when a local or
remote threshold crossing event is detected. A local
threshold crossing event is detected by the local entity,
while a remote threshold crossing event is detected by the
reception of an Ethernet OAM Event Notification OAMPDU
that indicates a threshold event.
This notification should not be sent more than once per
second.
The OAM entity can be derived from extracting the ifIndex from
the variable bindings. The objects in the notification
correspond to the values in a row instance in the
dot3OamEventLogTable.
The management entity should periodically check
dot3OamEventLogTable to detect any missed events.
Parsed from file rfc4878-OAM-Functions-on-Ethernet-Like-Interfaces.mib.txt
Company: None
Module: DOT3-OAM-MIB
A dot3OamThresholdEvent notification is sent when a local or
remote threshold crossing event is detected. A local
threshold crossing event is detected by the local entity,
while a remote threshold crossing event is detected by the
reception of an Ethernet OAM Event Notification OAMPDU
that indicates a threshold event.
This notification should not be sent more than once per
second.
The OAM entity can be derived from extracting the ifIndex from
the variable bindings. The objects in the notification
correspond to the values in a row instance in the
dot3OamEventLogTable.
The management entity should periodically check
dot3OamEventLogTable to detect any missed events.
Parsed from file DOT3-OAM-MIB.mib
Module: DOT3-OAM-MIB
Automatically extracted from RFC4878
dot3OamThresholdEvent NOTIFICATION-TYPE OBJECTS { dot3OamEventLogTimestamp, dot3OamEventLogOui, dot3OamEventLogType, dot3OamEventLogLocation, dot3OamEventLogWindowHi, dot3OamEventLogWindowLo, dot3OamEventLogThresholdHi, dot3OamEventLogThresholdLo, dot3OamEventLogValue, dot3OamEventLogRunningTotal, dot3OamEventLogEventTotal } STATUS current DESCRIPTION "A dot3OamThresholdEvent notification is sent when a local or remote threshold crossing event is detected. A local threshold crossing event is detected by the local entity, while a remote threshold crossing event is detected by the reception of an Ethernet OAM Event Notification OAMPDU that indicates a threshold event. This notification should not be sent more than once per second. The OAM entity can be derived from extracting the ifIndex from the variable bindings. The objects in the notification correspond to the values in a row instance in the dot3OamEventLogTable. The management entity should periodically check dot3OamEventLogTable to detect any missed events." ::= { dot3OamNotifications 1 }
dot3OamThresholdEvent NOTIFICATION-TYPE OBJECTS { dot3OamEventLogTimestamp, dot3OamEventLogOui, dot3OamEventLogType, dot3OamEventLogLocation, dot3OamEventLogWindowHi, dot3OamEventLogWindowLo, dot3OamEventLogThresholdHi, dot3OamEventLogThresholdLo, dot3OamEventLogValue, dot3OamEventLogRunningTotal, dot3OamEventLogEventTotal } STATUS current DESCRIPTION "A dot3OamThresholdEvent notification is sent when a local or remote threshold crossing event is detected. A local threshold crossing event is detected by the local entity, while a remote threshold crossing event is detected by the reception of an Ethernet OAM Event Notification OAMPDU that indicates a threshold event. This notification should not be sent more than once per second. The OAM entity can be derived from extracting the ifIndex from the variable bindings. The objects in the notification correspond to the values in a row instance in the dot3OamEventLogTable. The management entity should periodically check dot3OamEventLogTable to detect any missed events." ::= { dot3OamNotifications 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.158.0.2 | dot3OamNonThresholdEvent | 0 | 0 | A dot3OamNonThresholdEvent notification is sent when a local or remote non-threshold crossing event is detected. A local event i… |