t11FcSpSaControlInboundSpi OBJECT-TYPE
SYNTAX T11FcSpiIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SPI value of the ingress Security Association on
which was received the last frame for which a
t11FcSpSaNotifyAuthFailure was generated.
If no t11FcSpSaNotifyAuthFailure notifications have
been generated, the value of this object is zero."
View at oid-info.com
The SPI value of the ingress Security Association on
which was received the last frame for which a
t11FcSpSaNotifyAuthFailure was generated.
If no t11FcSpSaNotifyAuthFailure notifications have
been generated, the value of this object is zero.
Parsed from file rfc5324-Fibre-Channel-Security-Protocols-FC-SP.mib-5.txt
Company: ietf_rfcs
Module: T11-FC-SP-SA-MIB
Automatically extracted from RFC5324
t11FcSpSaControlInboundSpi OBJECT-TYPE SYNTAX T11FcSpiIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The SPI value of the ingress Security Association on which was received the last frame for which a t11FcSpSaNotifyAuthFailure was generated. If no t11FcSpSaNotifyAuthFailure notifications have been generated, the value of this object is zero." ::= { t11FcSpSaControlEntry 2 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.179.1.4.1.1.1 | t11FcSpSaControlAuthFailEnable | 0 | 0 | This object specifies whether a t11FcSpSaNotifyAuthFailure notification should be generated for the first occurrence of an Authen… |
1.3.6.1.2.1.179.1.4.1.1.3 | t11FcSpSaControlSource | 0 | 0 | The S_ID contained in the last frame for which a t11FcSpSaNotifyAuthFailure was generated. If no t11FcSpSaNotifyAuthFailure notif… |
1.3.6.1.2.1.179.1.4.1.1.4 | t11FcSpSaControlDestination | 0 | 0 | The D_ID contained in the last frame for which a t11FcSpSaNotifyAuthFailure was generated. If no t11FcSpSaNotifyAuthFailure notif… |
1.3.6.1.2.1.179.1.4.1.1.5 | t11FcSpSaControlFrame | 0 | 0 | The binary content of the last frame for which a t11FcSpSaNotifyAuthFailure was generated. If more than 256 bytes of the frame a… |
1.3.6.1.2.1.179.1.4.1.1.6 | t11FcSpSaControlElapsed | 0 | 0 | The elapsed time since the last generation of a t11FcSpSaNotifyAuthFailure notification on the same Fabric, or the value of sysUp… |
1.3.6.1.2.1.179.1.4.1.1.7 | t11FcSpSaControlSuppressed | 0 | 0 | The number of occurrences of an Authentication failure on a Fabric that were suppressed because they occurred on the same Fabric … |
1.3.6.1.2.1.179.1.4.1.1.8 | t11FcSpSaControlWindow | 0 | 0 | The length of a time window that begins when a t11FcSpSaNotifyAuthFailure notification is generated for any Security Association … |
1.3.6.1.2.1.179.1.4.1.1.9 | t11FcSpSaControlMaxNotifs | 0 | 0 | The maximum number of t11FcSpSaNotifyAuthFailure notifications to be generated per Fabric within a t11FcSpSaControlWindow time wi… |
1.3.6.1.2.1.179.1.4.1.1.10 | t11FcSpSaControlLifeExcdEnable | 0 | 0 | This object specifies whether t11FcSpSaNotifyLifeExceeded notifications should be generated for this Fabric. |
1.3.6.1.2.1.179.1.4.1.1.11 | t11FcSpSaControlLifeExcdSpi | 0 | 0 | The SPI of the SA that was most recently terminated because its lifetime (in seconds or in passed bytes) was exceeded. Such term… |
1.3.6.1.2.1.179.1.4.1.1.12 | t11FcSpSaControlLifeExcdDir | 0 | 0 | The direction of frame transmission on the SA that was most recently terminated because its lifetime (in seconds or in passed byt… |
1.3.6.1.2.1.179.1.4.1.1.13 | t11FcSpSaControlLifeExcdTime | 0 | 0 | The time of the most recent termination of an SA due to its lifetime (in seconds or in passed bytes) being exceeded. Such termin… |