t11FcSpSaControlSuppressed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of occurrences of an Authentication failure
on a Fabric that were suppressed because they occurred
on the same Fabric within the same time window as a
previous Authentication failure for which a
t11FcSpSaNotifyAuthFailure notification was generated.
The value of this object is reset to zero on a restart
of the network management subsystem, and whenever a
t11FcSpSaNotifyAuthFailure notification is generated.
In the event that the value of this object reaches its
maximum value, it remains at that value until it is
reset on the generation of the next
t11FcSpSaNotifyAuthFailure notification."
View at oid-info.com
The number of occurrences of an Authentication failure
on a Fabric that were suppressed because they occurred
on the same Fabric within the same time window as a
previous Authentication failure for which a
t11FcSpSaNotifyAuthFailure notification was generated.
The value of this object is reset to zero on a restart
of the network management subsystem, and whenever a
t11FcSpSaNotifyAuthFailure notification is generated.
In the event that the value of this object reaches its
maximum value, it remains at that value until it is
reset on the generation of the next
t11FcSpSaNotifyAuthFailure notification.
Parsed from file rfc5324-Fibre-Channel-Security-Protocols-FC-SP.mib-5.txt
Company: ietf_rfcs
Module: T11-FC-SP-SA-MIB
Automatically extracted from RFC5324
t11FcSpSaControlSuppressed OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of occurrences of an Authentication failure on a Fabric that were suppressed because they occurred on the same Fabric within the same time window as a previous Authentication failure for which a t11FcSpSaNotifyAuthFailure notification was generated. The value of this object is reset to zero on a restart of the network management subsystem, and whenever a t11FcSpSaNotifyAuthFailure notification is generated. In the event that the value of this object reaches its maximum value, it remains at that value until it is reset on the generation of the next t11FcSpSaNotifyAuthFailure notification." ::= { t11FcSpSaControlEntry 7 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.179.1.4.1.1.1 | t11FcSpSaControlAuthFailEnable | 0 | 0 | This object specifies whether a t11FcSpSaNotifyAuthFailure notification should be generated for the first occurrence of an Authen… |
1.3.6.1.2.1.179.1.4.1.1.2 | t11FcSpSaControlInboundSpi | 0 | 0 | The SPI value of the ingress Security Association on which was received the last frame for which a t11FcSpSaNotifyAuthFailure was… |
1.3.6.1.2.1.179.1.4.1.1.3 | t11FcSpSaControlSource | 0 | 0 | The S_ID contained in the last frame for which a t11FcSpSaNotifyAuthFailure was generated. If no t11FcSpSaNotifyAuthFailure notif… |
1.3.6.1.2.1.179.1.4.1.1.4 | t11FcSpSaControlDestination | 0 | 0 | The D_ID contained in the last frame for which a t11FcSpSaNotifyAuthFailure was generated. If no t11FcSpSaNotifyAuthFailure notif… |
1.3.6.1.2.1.179.1.4.1.1.5 | t11FcSpSaControlFrame | 0 | 0 | The binary content of the last frame for which a t11FcSpSaNotifyAuthFailure was generated. If more than 256 bytes of the frame a… |
1.3.6.1.2.1.179.1.4.1.1.6 | t11FcSpSaControlElapsed | 0 | 0 | The elapsed time since the last generation of a t11FcSpSaNotifyAuthFailure notification on the same Fabric, or the value of sysUp… |
1.3.6.1.2.1.179.1.4.1.1.8 | t11FcSpSaControlWindow | 0 | 0 | The length of a time window that begins when a t11FcSpSaNotifyAuthFailure notification is generated for any Security Association … |
1.3.6.1.2.1.179.1.4.1.1.9 | t11FcSpSaControlMaxNotifs | 0 | 0 | The maximum number of t11FcSpSaNotifyAuthFailure notifications to be generated per Fabric within a t11FcSpSaControlWindow time wi… |
1.3.6.1.2.1.179.1.4.1.1.10 | t11FcSpSaControlLifeExcdEnable | 0 | 0 | This object specifies whether t11FcSpSaNotifyLifeExceeded notifications should be generated for this Fabric. |
1.3.6.1.2.1.179.1.4.1.1.11 | t11FcSpSaControlLifeExcdSpi | 0 | 0 | The SPI of the SA that was most recently terminated because its lifetime (in seconds or in passed bytes) was exceeded. Such term… |
1.3.6.1.2.1.179.1.4.1.1.12 | t11FcSpSaControlLifeExcdDir | 0 | 0 | The direction of frame transmission on the SA that was most recently terminated because its lifetime (in seconds or in passed byt… |
1.3.6.1.2.1.179.1.4.1.1.13 | t11FcSpSaControlLifeExcdTime | 0 | 0 | The time of the most recent termination of an SA due to its lifetime (in seconds or in passed bytes) being exceeded. Such termin… |